Schneider Electric Acti9 iC60H Miniature Circuit Breaker
Overview
The Schneider Electric Acti9 iC60H is a DIN-rail mounted miniature circuit breaker (MCB) that extends the Acti9 iC60 platform to higher fault levels, offering a rated breaking capacity of 10kA across its B, C, and D curve variants up to 63A. Mechanically and dimensionally identical to the standard iC60N, the iC60H is specified wherever a short-circuit study shows prospective fault current at the final-distribution level exceeding the 6kA capacity of a standard-duty MCB, without requiring a change in panel layout or DIN-rail spacing. Compliant with IEC/EN 60898-1 and IEC/EN 60947-2, the iC60H is a common upgrade specification for distribution boards fed from larger transformers or located close to the main incomer, where prospective fault current is inherently higher.
As the official authorized partner and exclusive regional representative for Schneider Electric, Seven Star LLC proudly supplies the Schneider Electric Acti9 iC60H to electrical contractors, panel builders, and consulting engineers throughout the Sultanate of Oman and the wider GCC. Facilities in Muscat, Sohar, and Salalah requiring a formally documented 10kA breaking capacity for compliance with a short-circuit study can source genuine iC60H stock from Seven Star LLC, with full manufacturer test certificates and local technical support.
Operating Principle of the Schneider Electric Acti9 iC60H
The Schneider Electric Acti9 iC60H uses the same combined thermal-magnetic tripping principle as the rest of the iC60 family: a bimetallic thermal element trips on sustained overload current with an inverse-time characteristic, while a magnetic element trips near-instantaneously on the rapid current rise of a short circuit. The distinction of the H-duty variant lies in its internal contact and arc-quenching chamber design, engineered with a higher-rated arc chute and contact system to safely interrupt fault currents up to 10kA without contact welding or case rupture — a meaningful margin over the 6kA capacity typical of a standard-duty MCB in the same physical footprint.
Because the higher breaking capacity is achieved without increasing the physical envelope of the device, the iC60H can be substituted directly for an iC60N on the same DIN rail and busbar comb system wherever a fault-level review determines the additional interrupting margin is required, without redesigning the distribution board. As with the rest of the range, the iC60H is a self-contained electromechanical device requiring no external power, with a red mechanical trip indicator and trip-free operating mechanism that prevents the breaker from being held closed against a persistent fault.
Engineering Design of the Schneider Electric Acti9 iC60H
The Schneider Electric Acti9 iC60H retains the compact modular Acti9 case, with each pole occupying approximately 18mm of standard 35mm DIN-rail width, and is available in 1, 2, 3, and 4-pole configurations to match single-phase and three-phase final circuits. Screw terminals are sized for typical final-circuit cable cross-sections, and IP20-rated terminal shrouding protects against accidental contact once the breaker is installed behind a panel fascia. The toggle handle provides the same clear ON/OFF/tripped indication as the rest of the Acti9 family, and the device snaps directly onto standard DIN rail alongside busbar comb systems for fast multi-way panel assembly.
Because the iC60H shares its mounting footprint, terminal layout, and accessory compatibility with the iC60N and the rest of the Acti9 modular range — including RCDs, isolators, and surge protection devices — panel builders can mix standard and high-breaking-capacity MCBs within the same board without introducing additional part families, simplifying both design and future maintenance stock.
Key Features
The Schneider Electric Acti9 iC60H delivers extra fault-current margin without compromising the space efficiency of the standard Acti9 platform. Its principal characteristics include:
- Rated breaking capacity of 10kA, roughly 65% higher than the standard-duty iC60N in the same case size.
- Current ratings up to 63A, available in B, C, and D tripping curves for resistive, general, and inductive/inrush loads.
- 1, 2, 3, and 4-pole configurations for single-phase and three-phase circuit protection.
- Mechanically and dimensionally interchangeable with the iC60N, requiring no panel redesign to upgrade fault-current rating.
- Compact 18mm-per-pole modular design compatible with standard 35mm DIN rail and busbar comb systems.
- Red mechanical trip indicator and trip-free operating mechanism for clear fault status and safe manual operation.
- IP20-rated terminal protection against accidental contact behind the panel fascia.
- Compliant with IEC/EN 60898-1 and IEC/EN 60947-2, supported by full manufacturer test documentation.
Industrial Applications
The Schneider Electric Acti9 iC60H is specified wherever a short-circuit study identifies prospective fault current at the final-distribution level above the 6kA capacity of a standard MCB: sub-distribution boards close to a main incomer, panels fed from higher-capacity transformers, and industrial facilities with dense parallel motor loads. In Muscat’s commercial towers, Oman’s district cooling plants, and light industrial facilities across the Sohar and Salalah economic zones, the iC60H is the standard upgrade path when a consulting engineer’s fault-level calculation calls for additional interrupting margin at the final-circuit level.
As the officially authorized partner for Schneider Electric, Seven Star LLC distributes the iC60H to electrical contractors and panel builders across Oman and the GCC who need documented 10kA breaking capacity to satisfy project specifications and consulting engineer sign-off. Our regional stock and manufacturer test certification support ensure that fault-level compliance requirements can be met without delay on active site programs.
Technical Specifications
The table below summarizes the key technical parameters of the Schneider Electric Acti9 iC60H for specification and procurement purposes.
| Parameter | Specification |
|---|---|
| Model | Acti9 iC60H |
| Rated Current Range | 1A – 63A |
| Tripping Curves | B, C, D |
| Poles | 1P, 2P, 3P, 4P |
| Breaking Capacity | 10kA (IEC/EN 60898-1 / 60947-2) |
| Mounting | 35mm DIN rail, 18mm per pole |
| Terminal Protection | IP20 |
| Indication | Red mechanical trip indicator |
| Standards | IEC/EN 60898-1, IEC/EN 60947-2 |
Request a Quote for Schneider Electric Acti9 iC60H Miniature Circuit Breaker
Seven Star LLC supports formal RFQ submissions, technical datasheet requests, and regional stock checks for the Schneider Electric Acti9 iC60H across Oman and the GCC. As the authorized partner for Schneider Electric in Oman and the GCC, our low-voltage distribution division can advise on breaking-capacity selection and coordinated Acti9 board design for your project. Contact Seven Star LLC today to request a formal quotation, download the technical datasheet, or speak with our engineering team about sourcing the iC60H for your next fault-level-critical panelboard build in Muscat, Sohar, Salalah, or anywhere across the Sultanate of Oman.
Related Products
- Schneider Electric EasyPact CVS Molded Case Circuit Breaker
- Schneider Electric GV2ME08 TeSys Deca Motor Circuit Breaker
- Schneider Electric Sepam Series 20 Protection Relay
- Schneider Electric PowerPact H-Frame Circuit Breaker
- Schneider Electric Compact NSX400H High Breaking Capacity Breaker
- Schneider Electric Compact INS250 Load Break Switch



































Reviews