Brand: Galvanic
AccuChrome™ GC5 Gas Chromatograph Analyzer
Description
Overview
The AccuChrome™ GC5 represents a fundamental shift in gas chromatography, redefining the GC from a complex analytical instrument into a deployable, field-ready sensor. Built on silicon-miniaturized, modular GC technology, the GC5 delivers ultra-fast, high-precision multi-gas analysis in a dramatically smaller footprint, with far lower operational complexity than traditional process GCs, delivering laboratory-grade gas chromatography deployed like a sensor.
With engineering support in Muscat, Seven Star LLC offers the AccuChrome™ GC5 to natural gas custody transfer operators, biomethane producers, and gas quality monitoring programs across the Sultanate of Oman, Muscat, and the wider GCC. Purpose-engineered for continuous online operation and seamless integration with DCS and asset management systems, the GC5 supports high-accuracy custody transfer, natural gas quality monitoring, sulfur analysis, and biomethane measurement on a single platform using a single carrier gas.
Measurement Principle
The AccuChrome™ GC5 architecture supports up to four independent analytical chains, each with its own injector, column, and detector, operating in the same analyzer. Modular analytical cores enable faster deployment and reduced downtime, contributing to low mean time to repair (MTTR) in operational environments. The GC5 delivers exceptional analytical performance with high repeatability and robust limits of detection, using low carrier gas consumption with helium, hydrogen, or argon.
Multiple application-specific measurement suites are made possible by combining two detector styles: a micro-thermal conductivity detector (μTCD) and a patented nano-gravimetric detector (NGD), the latter expanding measurement capability beyond conventional process GCs. Standard heating value calculations comply with ASTM D3588 (GPA 2172) and ISO 6976, and one-click operation delivers C1-C6 heating value analysis in under two minutes, reducing operator burden and specialist dependency.
Engineering Design of the AccuChrome™ GC5
The AccuChrome™ GC5 is designed with measurement certainty at its core: built-in self-verification reduces calibration and maintenance demand to once a year, and the modular analytical core design speeds deployment while reducing downtime. Its small footprint is purpose-built for automated operations and remote access, integrating with control systems using Modbus protocols over either TCP/IP or RTU.
The GC5 achieves high repeatability (10% RSD) and robust limits of detection (2ppm or less), with carrier gas consumption of 20 sccm or less and sample gas consumption of 30 sccm or less—a significant reduction compared with legacy process GC platforms. This efficiency directly translates into lower operating cost and less frequent gas cylinder replacement for continuously operating installations. The AccuChrome™ GC5 is available in enclosure configurations matched to the area classification of the installation site: a stainless steel NEMA 4/4X, IP65 enclosure for Class I Division 2 duty, a cast-aluminum NEMA 4/4X/7, IP65 enclosure for Class I Division 1 installations, and a Zone 1-rated cast-aluminum NEMA 3, IP54 version certified Ex db [ia Ga] IIB + H2 T3 Gb for ambient temperatures from −20°C to +60°C under ATEX and IECEx schemes, alongside CEC/NEC Class I Division 1 and Division 2, Groups B, C, D, T3 certification and Measurement Canada approval for custody transfer duty. Power requirements are modest at 24 VDC or 90 to 240 VAC, drawing up to 100 W at start-up and settling to 50 W running, and the analyzer operates across an ambient range of −20°C to +60°C at up to 95% non-condensing relative humidity, extending to a 50°C limit when fitted with the NEMS sample-conditioning enclosure. Standard dimensions are 686 x 838 x 318 mm (27 x 33 x 12.5 in) at approximately 38.6 kg (85 lb) for the Division 2 build, rising to roughly 54.4 kg (120 lb) for the Division 1 and Zone 1 versions and up to 81.6 kg (180 lb) with the full NEMS package fitted; local RS232 and RS485 serial ports and a PC-based GUI over Ethernet supplement the standard Modbus TCP/IP and RTU links already used for DCS integration.
Available Models & Measurement Capability
The AccuChrome™ GC5 is offered in application-specific configurations to match specific measurement needs:
- BTU: C1 to C6 heating value analysis in 2 minutes with 50 ppm-mol LDL; C1 to C10 in 5-7 minutes with 10 ppm-mol LDL; also measures nitrogen, oxygen, and carbon dioxide.
- BTU + H2S: Combines heating value analysis with hydrogen sulfide monitoring for custody transfer and gas processing.
- BTU + Odorants: Complete C1-C6 heating value and odorant analysis in 2 minutes, measuring common mercaptan odorants (TBM, THT, IPM, NBM, SBM) with 2 ppm-mol LDL.
- SULFUR: Sulfur compound speciation including hydrogen sulfide (H2S), carbonyl sulfide (COS), carbon disulfide (CS2), dimethyl sulfide (DMS), C1-C4 mercaptans, and more.
- BIOGAS: Heating value and quality measurement for biogas, biomethane, and RNG production in 2 minutes, with H2S detection as low as 3 ppm-mol.
- SILOXANES + VOC: The only purpose-built GC for siloxanes and VOCs hazardous-rated for operations, with complete analysis in under 5 minutes.
Key Features
The AccuChrome™ GC5 combines modular flexibility with laboratory-grade precision. Core capabilities include:
- Up to 4 independent analytical chains (injector, column, detector) in a single analyzer.
- C1-C6 heating value analysis in under 2 minutes with one-click operation.
- Built-in self-verification reducing calibration and maintenance to once per year.
- High repeatability (10% RSD) and robust limits of detection (2ppm or less).
- Compliant with ASTM D3588 (GPA 2172) and ISO 6976 for heating value calculation.
- Low carrier gas consumption (20 sccm or less) using helium, hydrogen, or argon.
- Modbus protocol integration on TCP/IP or RTU for DCS and asset management systems.
- Patented nano-gravimetric detector (NGD) expanding measurement beyond conventional process GCs.
Industrial Applications
The AccuChrome™ GC5 is engineered for natural gas custody transfer, pipeline quality monitoring, gas processing, odorant stations, gas sweetening, and biogas/biomethane production across Oman’s energy sector. Its compliance with CAN/BNQ 3672-100, PG&E Gas Rule 21, and SoCalGas Rule 30 also supports operators exporting to markets with strict biomethane and RNG quality standards.
Backed by manufacturer datasheet documentation, Seven Star LLC supports gas transmission operators, biomethane producers, and custody transfer stations throughout the Sohar and Salalah economic zones and the broader GCC region with the GC5’s compact, field-deployable measurement certainty.
Technical Specifications
Full technical parameters for the AccuChrome™ GC5:
| Parameter | Specification |
|---|---|
| Model | AccuChrome™ GC5 |
| Analytical Chains | Up to 4 Independent Chains (Injector, Column, Detector) |
| Analysis Time (C1-C6) | Under 2 Minutes |
| Repeatability | 10% RSD |
| Limits of Detection | 2ppm or Less |
| Carrier Gas | Helium, Hydrogen, or Argon; 20 sccm or Less |
| Sample Gas Consumption | 30 sccm or Less |
| Detector Types | μTCD and Patented Nano-Gravimetric Detector (NGD) |
| Communication | Modbus TCP/IP or RTU |
| Standards Compliance | ASTM D3588 (GPA 2172), ISO 6976 |
| Calibration Interval | Once per Year (Built-in Self-Verification) |
| Available Configurations | BTU, BTU+H2S, BTU+Odorants, Sulfur, Biogas, Siloxanes+VOC |
| Enclosure Rating | NEMA 4/4X IP65 (Div. 2); NEMA 4/4X/7 IP65 (Div. 1); NEMA 3 IP54 (Zone 1) |
| Hazardous Area Certification | CEC/NEC Cl. I Div. 1 & 2, Groups B,C,D, T3; ATEX/IECEx Zone 1 Ex db [ia Ga] IIB+H2 T3 Gb |
| Power Supply | 24 VDC or 90–240 VAC; 100 W start-up, 50 W running |
| Ambient Operating Range | −20°C to +60°C, up to 95% RH non-condensing |
| Dimensions / Weight | 686 x 838 x 318 mm; 38.6–81.6 kg depending on configuration |
Request a Quote for AccuChrome™ GC5 Gas Chromatograph Analyzer
To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the AccuChrome™ GC5 Gas Chromatograph Analyzer, please contact Seven Star LLC today. Working closely with plant engineers in the region, our engineers are ready to assist with rapid sourcing for your natural gas quality and custody transfer projects.
Related Products
- Teledyne 8800B Trace Moisture Analyzer – 8800 Series
- Michell Easidew EA2 Dew-Point Transmitter
- Galvanic 943-TGX Sulfur Plant Tail Gas Analyzer
- BARTEC HYGROPHIL F 5674 Process Trace Moisture Analyzer 5674-xx
- ABB Uvisor SF810i Integrated Safe Flame Scanner
- Michell CD2-WDC-002 Water Dew-Point Sensor Assembly
Datasheets & Documents
- Brochure Galvanic AccuChrome GC Analyzer Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hydrogen sulfide measurement in natural gas is where Galvanic Applied Sciences built its name, and its lead acetate tape analyzers are written into many gas quality specifications. The company was founded in 1975 and is based in Calgary, Canada. Seven Star LLC sources and supplies Galvanic process analyzers for gas and liquid streams, together with their consumables and spare parts, for operators in Oman, working from the analyzer model, serial number and application data.
Galvanic analyzer families listed here
Galvanic analyzers on this page fall into three groups:
- Sulfur and gas quality: ProTech903 and ProTech 1000 Z2 tape-based H2S and total sulfur analyzers, the AccuLase-GPA tunable diode laser analyzer for H2S, CO2 and H2O, and AccuChrome gas chromatographs for heating value and composition
- Sulfur recovery: Brimstone analyzer systems and the 943-TGX tail gas analyzer
- Liquids and photometry: Monitek turbidity, suspended solids and color monitors, Monitek Ultrasonic oil-in-water monitors, the AccuSeries-LPA wet chemistry analyzer, the Viscosite in-line viscometer and FPA 4100 UV photometers
GasMicro and GasMicro NG electronic volume correctors complete the list.
Where Galvanic analyzers are used
The manufacturer names natural gas processing, pipelines and distribution, refining and oil production, chemical and petrochemical production, power and biogas, water and wastewater, and food and beverage as its markets. In the GCC the common duties are H2S and total sulfur at sales gas and custody transfer points, tail gas control on Claus sulfur recovery units, heating value measurement, and oil-in-water monitoring of produced water.
Ordering Galvanic analyzers and parts: what we need
For a new Galvanic H2S analyzer or chromatograph, send the stream composition, the component and range to be measured, sample pressure and temperature, the number of streams, area classification, power supply and the outputs required. For consumables and spares such as sensing tape, lamps, columns or pump parts, send the analyzer model and serial number and the part number from the manual. Manuals differ by generation, so a nameplate photo helps us check the item against the manufacturer's documentation.
Browse Galvanic products by category: Gas Analyzer Systems, Liquid Analytical Systems, Flow Computers.
Related products
Frequently Asked Questions
The GC5 delivers C1-C6 heating value analysis in under 2 minutes with one-click operation, and C1-C10 analysis in 5-7 minutes depending on application.
The GC5 includes built-in self-verification that reduces calibration and maintenance demand to once per year, supporting reliable long-term field deployment.
The GC5 is available in BTU, BTU+H2S, BTU+Odorants, Sulfur, Biogas, and Siloxanes+VOC configurations, each tailored to specific measurement needs.
The GC5 complies with ASTM D3588 (GPA 2172) and ISO 6976 for heating value calculation, and supports CAN/BNQ 3672-100, PG&E Gas Rule 21, and SoCalGas Rule 30 for biomethane applications.
Yes. Seven Star LLC is an experienced supplier of Galvanic Applied Sciences instrumentation in Oman and the GCC, providing genuine products with full support.