- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: SMC
SMC ITVH2020-012S ITVH2000 High Pressure E/P Regulator
Description
SMC ITVH2020-012S ITVH2000 high pressure electro-pneumatic regulator
The SMC ITVH2020-012S belongs to the ITVH2000 series, the high pressure version of the electro-pneumatic regulator. It accepts a maximum supply pressure of 3.0 MPa and delivers a stepless output pressure between 0.2 and 2.0 MPa that follows an electrical command. The SMC ITVH2020-012S uses a 4 to 20 mA DC current (sink type) command signal and has 1/4 inch ports.
Where a standard 1.0 MPa class electro-pneumatic regulator runs out of range, the ITVH2020-012S offers a way to control higher air pressures from a PLC or DCS analog output. The catalog lists proof pressure testing of tanks, leak testers, discharge rate control, tension control and pressure control for adhesive application among the typical uses of the series, and it can also be used to give a remote set point to a high pressure air-operated regulator.
A digital display on the body shows the output pressure. The weight is approximately 630 g without options, and the parts in contact with the fluid are described as fluorine grease, which is relevant when you check compatibility with your air quality. For a replacement job, matching the complete ITVH2020-012S code is the safest route.
Key features of the ITVH2020-012S
- Maximum supply pressure of 3.0 MPa with a set pressure range of 0.2 to 2.0 MPa.
- Stepless control from a 4 to 20 mA DC current (sink type) command; the supply is 24 VDC.
- Maximum flow rate of 3000 L/min (ANR) at a supply pressure of 3.0 MPa and a set pressure of 1.0 MPa, as shown in the catalog.
- Linearity of plus or minus 1 percent of full scale, hysteresis of 1 percent of full scale and repeatability of plus or minus 1 percent of full scale, all or better, in static conditions.
- Power consumption of 3 W or less.
- Digital pressure display with an accuracy of plus or minus 2 percent of full scale plus or minus 1 digit.
- Ports of 1/4 inch; flat bracket and L-bracket accessories are available for the series.
- Pipe thread options of Rc, NPT and G exist in the series code, with this variant using the standard Rc thread.
ITVH2020-012S technical specifications
The table below lists the values the manufacturer publishes for the ITVH2020-012S and its series. Always confirm the final configuration against the datasheet before ordering.
| Parameter | Value |
|---|---|
| Series | ITVH2000 high pressure electro-pneumatic regulator |
| Part number | ITVH2020-012S |
| Maximum supply pressure | 3.0 MPa |
| Minimum supply pressure | Whichever is higher: 0.5 MPa or the set pressure plus 0.2 MPa |
| Set pressure range | 0.2 to 2.0 MPa |
| Power supply | 24 VDC plus or minus 10 percent, 0.12 A or less |
| Input signal | 4 to 20 mA DC current (sink type) |
| Monitor output | Analog output 1 to 5 VDC (variant code 1) |
| Linearity | Plus or minus 1 percent F.S. or less |
| Hysteresis | 1 percent F.S. or less |
| Repeatability | Plus or minus 1 percent F.S. or less |
| Temperature characteristic | Plus or minus 0.12 percent F.S. per degree C or less |
| Ambient and fluid temperature | 0 to 50 C, no condensation |
| Port size | 1/4 (Rc) |
| Weight | About 630 g without options |
Typical applications in Oman and the GCC
In oil and gas and petrochemical facilities, the ITVH2020-012S suits test stands and skids that need a high pressure air set point from the control system, such as pressure testing of small vessels, leak testing of components or remote loading of a high pressure air-operated regulator. In water and utility plants it can set the control air pressure of special actuators that run above the usual 0.7 MPa instrument air level.
In manufacturing across the GCC, the ITVH2020-012S is used in bottle blowing and forming lines, adhesive and sealant dispensing, tension control and press loading, all of which benefit from a stepless pressure that can be changed from a recipe. Because it is controlled by an analog signal, it integrates with PLC analog modules without special communication cards.
High pressure electro-pneumatic regulators answer a specific problem: the standard instrument air range is often below 1.0 MPa, but processes such as stretch blow molding, hydrostatic or pneumatic testing and some pressing operations need a stepless pressure above that level. Controlling such a pressure with a manual regulator makes recipe changes slow and operator dependent, while an electronic regulator allows the pressure to be set from the controller and logged with the batch data.
Because the supply can be as high as 3.0 MPa, the surrounding piping, fittings and any downstream vessel must be rated accordingly. The regulator regulates the output pressure, but it does not replace a safety relief device, so a relief valve or pressure switch suited to the circuit should be included in the design. This is general good engineering practice for any compressed gas system and should be confirmed against the local rules applicable to your site.
Buyers in the Gulf region often ask for this family when a compressed air test bench is being refurbished or a bottle-forming line is being upgraded. Sending the nameplate details with your RFQ allows us to check the code digits and confirm the right voltage, signal and port size before the order is placed.
Selection and compatibility notes for the ITVH2020-012S
Check that the plant has a supply of at least 0.5 MPa, or at least 0.2 MPa above the set pressure, whichever is higher; the ITVH2020-012S will not regulate correctly if the supply is below this margin. The supply must not exceed 3.0 MPa.
The ITVH2020-012S is a 24 VDC unit with a 4 to 20 mA DC current (sink type) command. If your control system provides a different signal, choose the matching variant of the series code. The monitor output of this variant is analog 1 to 5 VDC, which should be measured with a high impedance input to keep the specified accuracy.
The catalog notes that the product is not certified under Japan’s High Pressure Gas Safety Act, so users should check the regulations that apply to their own installation before using the unit on compressed gas systems.
Reading the part number
- ITVH: high pressure electro-pneumatic regulator series; 2000: size class.
- 2 in the pressure range position: set pressure 0.2 to 2.0 MPa; 0: 24 VDC supply.
- 0: input signal 4 to 20 mA DC current (sink type).
- 1: analog output 1 to 5 VDC.
- 2: port size 1/4 inch.
- S: straight cable connector with a 3 m cable.
Installation and commissioning of the ITVH2020-012S
Mount the ITVH2020-012S in the orientation shown in the datasheet, with the display accessible, and use the flat or L-bracket if the unit is not panel mounted. Fit a filter upstream, connect the supply and output piping with fittings rated for the pressures involved, and route the exhaust where it will not carry dust back into the unit.
Connect the 24 VDC supply and the 4 to 20 mA DC current (sink type) signal using the 3 m cable that comes with the straight connector. After power-up, command a low value first, verify the display and the output with a calibrated gauge, and then step up gradually to the working pressure. Always depressurize the circuit before disconnecting any fitting of the ITVH2020-012S.
Maintenance and service life
Keep the supply air clean, dry and free of oil mist so that the internal valve parts of the ITVH2020-012S stay clean. Check the displayed pressure against a reference gauge during scheduled calibration rounds and inspect fittings for leaks.
If the output cannot follow the command, check the supply margin, the wiring and the signal level first. Replacement should be made with the same code, and the ITVH2020-012S code should be recorded in the equipment list.
Related products and ordering notes
For lower pressures, the ITV1000, ITV2000 and ITV3000 series cover the 0.1, 0.5 and 0.9 MPa classes with a similar code structure. For accessories such as the flat bracket and L-bracket assemblies and the cable connectors, include the part numbers from the datasheet in your RFQ together with the ITVH2020-012S.
Frequently asked questions about the ITVH2020-012S
- What is the output range of the ITVH2020-012S? The ITVH2020-012S sets an output pressure between 0.2 and 2.0 MPa from a supply pressure of up to 3.0 MPa.
- What input signal does the ITVH2020-012S use? The ITVH2020-012S is controlled by a 4 to 20 mA DC current (sink type) signal and powered by 24 VDC.
- What is the minimum supply pressure for the ITVH2020-012S? The supply must be the higher of 0.5 MPa and the set pressure plus 0.2 MPa.
- How heavy is the ITVH2020-012S? The catalog gives an approximate weight of 630 g without options, so it can be mounted on a bracket or panel easily.
- How do I request a quotation for the ITVH2020-012S? Send an RFQ to Seven Star LLC with the part number ITVH2020-012S, the quantity and your delivery location, and our team will confirm availability and lead time.
Documents and quotation
The manufacturer catalog covering the ITVH2020-012S is available as a datasheet download on this page, and it is the document to check for dimensions, wiring and option codes. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To receive a quotation, send the RFQ with the part number ITVH2020-012S, the quantity, the required voltage or signal, the connection standard and your delivery location in Oman or the GCC. Our team will confirm availability and lead time for the ITVH2020-012S and reply with a formal offer.
Other Models in the ITVH2000 Range
Seven Star LLC supplies models from the ITVH2000 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| SMC ITVH2020-012S ITVH2000 High Pressure E/P Regulator | Regulators | You are viewing this model |
| SMC ITVH2020-313S ITVH2000 High Pressure E/P Regulator | Regulators | View details |
Datasheets & Documents
- Datasheet SMC ITVH2020-012S Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SMC is the Japanese specialist in pneumatic automation: air preparation units, solenoid valves, cylinders, fittings, process valves and sensors. Yoshiyuki Takada founded the company in Tokyo on 27 April 1959 as Shoketsu Kinzoku Kogyo, which means Sintered Metal Corporation, and its first products were sintered metal filters. SMC Corporation is headquartered in Tokyo and listed on the Tokyo Stock Exchange, and its products are used on machines and instrument air lines across the world.
Seven Star LLC, an independent supplier in Oman, lists SMC AW series filter regulators (AW20 and AW40) and the VX2 series direct-operated 2-port solenoid valve, and sources other SMC parts by full part number.
SMC company profile
| Founded | 27 April 1959, Tokyo, Japan, as Shoketsu Kinzoku Kogyo (Sintered Metal Corporation) |
|---|---|
| Founder | Yoshiyuki Takada (1928–2024) |
| First products | Sintered metal filters; pneumatic air line equipment from 1961 |
| Headquarters | Tokyo, Japan |
| Ownership | SMC Corporation, a public company listed on the Tokyo Stock Exchange |
| Product families | AF/AR/AW modular air preparation, VT/VQ/SY solenoid valves, VX/VXZ 2-port valves, air cylinders and rotary actuators, fittings and tubing, pressure and flow switches, vacuum equipment |
Milestones
- 1959: Shoketsu Kinzoku Kogyo is founded in Tokyo on 27 April and starts making sintered metal filters.
- 1961: Pneumatic air line equipment is added.
- 1964: Automatic control equipment becomes part of the business.
- 1967: The first overseas operation starts, with a stake in an Australian company.
- 1970: SMC begins making air cylinders.
SMC series listed on this page
The AW is a combined filter and pressure regulator in SMC's modular air preparation line. The body size is in the name: AW20 is the smaller unit and AW40 the larger, and the digits after the dash give the port size. A part number such as AW40-04-A therefore describes body size, port and options in one string. The VX2 is a direct-operated two-port solenoid valve for shutting off air, water, oil or steam, depending on the body and seal materials chosen.
SMC products we list
Ordering SMC parts: what we need
Give the complete SMC part number from the label, including thread prefix, options and the final suffix letter. For AW units state gauge, drain type and bracket if you need them. For VX2 valves send coil voltage, port size, orifice, body and seal material, and the fluid. Buyers in the GCC often have NPT or G threads on site, so say which thread standard the piping uses.
Facts checked against SMC's published corporate history, October 2026.
Browse SMC products by category: Regulators, Solenoid Valve.
FAQ
Questions about the SMC ITVH2020-012S ITVH2000 High Pressure E/P
Answers from our engineering team on installation, compatibility and integration.
01What is the output range of the ITVH2020-012S?
The ITVH2020-012S sets an output pressure between 0.2 and 2.0 MPa from a supply pressure of up to 3.0 MPa.
02What input signal does the ITVH2020-012S use?
The ITVH2020-012S is controlled by a 4 to 20 mA DC current (sink type) signal and powered by 24 VDC.
03What is the minimum supply pressure for the ITVH2020-012S?
The supply must be the higher of 0.5 MPa and the set pressure plus 0.2 MPa.
04How heavy is the ITVH2020-012S?
The catalog gives an approximate weight of 630 g without options, so it can be mounted on a bracket or panel easily.
05How do I request a quotation for the ITVH2020-012S?
Send an RFQ to Seven Star LLC with the part number ITVH2020-012S, the quantity and your delivery location, and our team will confirm availability and lead time.


















Reviews
There are no reviews yet.