Schneider Electric ZB4BZ102 XB4 Contact Block 1 NC

Description

ZB4BZ102: Harmony XB4 contact block with collar, 1 NC

The ZB4BZ102 is a Schneider Electric Harmony XB4 complete body and contact assembly with one normally closed contact, screw clamp terminals and a zamak fixing collar. Seven Star LLC supplies the ZB4BZ102 in Oman and the GCC as an independent supplier based in Muscat, for panel builders and maintenance teams working on metal-style push-button and selector stations.

The datasheet lists the device composition as a fixing collar and a body, with the contact composition shown as 1 NC and the block type as single. It is the part that actually switches the circuit when a head is operated. The ZB4BZ102 is sold without any head, so the push button, selector or pilot light that sits in front of it is a separate item. The datasheet does not decode the reference, so the only reading offered comes from the catalogue title.

Typical uses of the ZB4BZ102 in Oman and the GCC

A contact block of this type sits behind push buttons, selector switches and pilot lights on motor control stations, pump houses, desalination plants, packaged skids and switchgear doors in oil and gas, petrochemical, power and water facilities. The this unit is the part that makes or breaks the control circuit, so it takes the electrical wear in a station. In the Gulf, heat and dust inside enclosures raise contact wear, so maintenance teams carry spare blocks and replace them on a schedule.

The block is rated at IP20, so it belongs behind the panel, protected by the head, the panel and the enclosure.

Electrical ratings of the ZB4BZ102

The datasheet gives a conventional thermal current of 10 A and a short-circuit protection of a 10 A gG cartridge fuse. Rated operational currents include 3 A at 240 V and 6 A at 120 V in AC-15, and 0.55 A at 125 V, 0.27 A at 250 V and 0.1 A at 600 V in DC-13. The contact material is a silver alloy (Ag/Ni). Rated insulation voltage is 600 V at pollution degree 3 and the rated impulse withstand voltage is 6 kV.

Electrical durability is stated as 10 000 000 cycles for several loads, including AC-15 at 3 A and 120 V and DC-13 at 0.5 A and 24 V, and mechanical durability is 5 000 000 cycles. For low-level signals, the datasheet gives a reliability figure for 5 V at 1 mA and for 17 V at 5 mA in a clean environment, which is useful for PLC inputs.

Installation and maintenance of the ZB4BZ102

Clip the this unit onto the back of the head with the collar engaged in the panel hole, and tighten the terminal screws at the datasheet torque. Mark the circuit numbers on the wiring, and check continuity with a meter both at rest and with the head pressed: a normally open contact should read open at rest, a normally closed contact should read closed. Where two blocks are stacked, check that both operate fully.

In maintenance, a worn or contaminated contact block shows up as an intermittent signal. Replace the this unit rather than cleaning it, because the contacts are sealed into the body. Keep spare blocks of each composition on site for critical stations.

Contact arrangement of the ZB4BZ102

The this unit carries one normally closed contact. A normally closed contact is closed at rest and opens when the head is pressed, which is the usual arrangement for stop and safety-related circuits; the datasheet lists the terminals and the block carries the markings 1 and 2.

The datasheet describes the contact operation as slow-break, positive opening as without, and the contact usage as standard. That means these contacts are not the safety-rated kind with positive opening, so they should not be used for emergency stop circuits that need direct opening action.

Mounting and terminals of the ZB4BZ102

The this unit is 30 mm wide, 47 mm high and 37 mm deep, with a weight of 0.053 kg. The body clips behind a head in a panel hole, and the zamak collar clamps it into position. Terminals are screw clamps for up to two conductors of 1.5 mm² with cable ends, or a single conductor of 0.22 mm² or larger without an end, tightened to 0.8 to 1.2 N.m. The datasheet lists the screw heads as compatible with Philips No 1, pozidriv No 1 and 4 mm or 5.5 mm flat drivers.

Operating travel is 2.6 mm to change state and 4.3 mm in total, with an operating force of 2.3 N and a torque of 0.05 N.m, so a pushbutton or selector with a standard head will feel normal.

The ZB4BZ102 compared with other XB4 contact blocks

Five complete body and contact assemblies in this lane share the 30 × 47 mm body and the zamak collar. They differ in contact count and type, and in weight.

Reference Contacts Weight
ZB4BZ101 1 NO 0.053 kg
ZB4BZ102 1 NC 0.053 kg
ZB4BZ103 2 NO 0.062 kg
ZB4BZ104 2 NC 0.062 kg
ZB4BZ105 1 NO + 1 NC 0.062 kg

The count and the type of contacts are the decision: use normally open for make circuits, normally closed for break circuits, and mixed for one-button dual function.

Selection checklist for the ZB4BZ102 and RFQ details

  • Reference this unit and quantity.
  • Contact composition: 1 NC.
  • Head type that will sit in front, which must be compatible with this block.
  • Load voltage, current and category (AC-15 or DC-13), compared with the datasheet.
  • Whether a safety-rated positive-opening block is required instead; this one is not.
  • Space behind the panel for a body 47 mm high and 37 mm deep.

For the RFQ, send:

  • Part number ZB4BZ102 and quantity.
  • The head type and its part number.
  • Control voltage, current and load type.
  • Contact composition required.
  • Delivery location and schedule.

Technical specifications of the ZB4BZ102

Parameter Specification
Manufacturer / part number Schneider Electric / ZB4BZ102
Range Harmony XB4
Product type Complete body/contact assembly
Contact composition 1 NC
Contact block type Single
Contact operation Slow-break
Contacts usage Standard contacts
Positive opening With conforming to IEC 60947-5-1 appendix K
Contact material Silver alloy (Ag/Ni)
Device composition Fixing collar, body
Fixing collar material Zamak
Terminal marking (ISO) (11-12)NC
Terminals Screw clamp; ≤ 2 × 1.5 mm² with cable end; ≥ 1 × 0.22 mm² without cable end
Tightening torque 0.8–1.2 N.m
Operating travel 2.6 mm to change state, 4.3 mm total
Operating force 2 N NC changing electrical state
Mechanical durability 5 000 000 cycles
Thermal current [Ith] 10 A (IEC 60947-5-1)
Short-circuit protection 10 A cartridge fuse type gG
Rated insulation voltage [Ui] 600 V, pollution degree 3
Rated impulse withstand [Uimp] 6 kV
Rated operational current [Ie] 3 A at 240 V, AC-15, A600; 6 A at 120 V, AC-15, A600; 0.1 A at 600 V, DC-13, Q600; 0.27 A at 250 V, DC-13, Q600; 0.55 A at 125 V, DC-13, Q600; 1.2 A at 600 V, AC-15, A600
Overall size (W × H × D) 30 × 47 × 37 mm
Net weight 0.053 kg
Degree of protection IP20 conforming to IEC 60529
Operating / storage temperature -40–70 °C / -40–70 °C
Certifications BV, UL, CSA, DNV, LROS (Lloyds register of shipping)
Standards CSA C22.2 No 14, IEC 60947-5-5, IEC 60947-5-1, UL 508, JIS C8201-5-1, IEC 60947-1, IEC 60947-5-4, JIS C8201-1
Warranty 18 months

Documents and quotation

The Schneider Electric datasheet for the ZB4BZ102 is attached on this page for your technical file. It carries the dimensions, electrical and environmental data summarised above, and is the document to compare with your project requirement before you order.

To request a quotation, send the part number ZB4BZ102, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and does not act for the manufacturer, so please check that the datasheet data suits your application before ordering.

Other Models in the Se Xb4 Contact Block Range

Seven Star LLC supplies models from the Se Xb4 Contact Block range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric ZB4BZ101 XB4 Contact Block 1 NOAutomation AccessoriesView details
Schneider Electric ZB4BZ102 XB4 Contact Block 1 NCAutomation AccessoriesYou are viewing this model
Schneider Electric ZB4BZ103 XB4 Contact Block 2 NOAutomation AccessoriesView details
Schneider Electric ZB4BZ104 XB4 Contact Block 2 NCAutomation AccessoriesView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric ZB4BZ102 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ZB4BZ102 XB4 Contact Block 1 NC

Answers from our engineering team on installation, compatibility and integration.

01What contacts does the ZB4BZ102 have?
1 NC, single block, slow-break operation, silver alloy (Ag/Ni) contacts.
02Does the ZB4BZ102 have positive opening?
No. The datasheet lists positive opening as without, so it is not a safety-rated positive-opening block.
03What current can the ZB4BZ102 switch?
The datasheet lists a thermal current of 10 A and AC-15 ratings of 3 A at 240 V and 6 A at 120 V, with DC-13 ratings down to 0.1 A at 600 V.
04Does the ZB4BZ102 include a fixing collar?
Yes. The device composition lists a fixing collar and a body.
05Does Seven Star LLC supply the ZB4BZ102 in Oman?
Yes, as an independent supplier in Muscat serving Oman and the GCC. Send the part number and quantity and we reply with availability.