Schneider Electric XA2EVF4LC Red 110 V AC/DC LED Pilot Light

Description

XA2EVF4LC: red 110 V AC/DC Harmony XA2 LED pilot light

The XA2EVF4LC is a Schneider Electric Harmony XA2 monolithic pilot light for a 22 mm panel hole, with a red round cap, a built-in clustered LED and a rated supply of 110 V AC or DC, 50/60 Hz. Seven Star LLC supplies the XA2EVF4LC in Oman and the GCC as an independent supplier based in Muscat, usually to panel builders, maintenance stores and EPC contractors who need indicators that match an existing control scheme.

Unlike a lamp-holder design, this unit is monolithic: the LED and its supply electronics are sealed inside the body, and the datasheet lists the bulb base as none. There is no lamp to change, which is the main practical difference from older incandescent indicators. A reading of the reference that fits the datasheet titles of its siblings is XA2EV for the family, F for the supply group, 4 for the red cap and LC for the anti-interference electronics version; this is our interpretation, not a published ordering table.

Technical specifications of the XA2EVF4LC

Parameter Specification
Manufacturer / part number Schneider Electric / XA2EVF4LC
Range Harmony XA2
Product type Monolithic pilot light
Device short name XA2
Colour of cap / lens Red
Head shape Round
Light source COB clustered LED
Bulb base No bulb
Rated supply voltage [Us] 110 V AC/DC 50/60 Hz
Supply voltage limits 0.8 to 1.2 times Us
Current consumption ≤ 20 mA
Signalling type Steady
Service life 40000 h at rated voltage and 25 °C
Mounting diameter 22.5 mm
Fixing hole 22.5 mm ± 0.2, conforming to IEC 60947-5-1
Fixing nut torque 2.2 N.m (± 0.2 N.m)
Terminals Screw clamp; up to 2 × 1.5 mm² with cable end, or 1 x 0.5 to 1 x 2.5 mm² without
Terminal marking (ISO) (X1-X2)PL
Rated insulation voltage [Ui] 400 V, pollution degree 3
Rated impulse withstand [Uimp] 6 kV
Dimensions (H x W x D) 29 mm × 29 mm × 53 mm
Net weight 0.02 kg
Operating temperature -25 to 70 °C
Storage temperature -40 to 70 °C
Degree of protection IP65 (IEC 60529), IK05
Vibration / shock 5 gn, 12–500 Hz / 30 gn, 11 ms half sine
Marking CE, CCC
Product certifications CE, CCC
Warranty 18 months

Supply voltage and LED behaviour

The 110 V AC/DC rating is the flexible member of the range. One lamp runs from a 110 V AC control transformer secondary or from a 110 V DC battery or rectified supply, so a panel that mixes both supplies, or a plant that is migrating from one to the other, can keep a single part number for these indicators. The datasheet lists the supply as 50/60 Hz.

The datasheet gives the supply limits as 0.8 to 1.2 times the rated value, which for XA2EVF4LC works out to roughly 88 to 132 V. Within that window XA2EVF4LC gives a signalling type that is steady, and its current consumption is stated as not more than 20 mA. The light source is a clustered chip-on-board LED, and the quoted service life is 40000 h at rated voltage and 25 °C, so continuous duty of XA2EVF4LC in a normally ventilated panel is the intended use. Driving the lamp at the top of its voltage window or in a hot enclosure will shorten that figure, as with any LED.

The XA2EV LC family and how XA2EVF4LC differs

The lamps in this lane share the same 29 mm head, the same IP65 rating and the same 40000 h LED life, and are separated by supply and colour. That makes selection a two-step choice: first the supply that matches your control circuit, then the colour that matches your panel legend. XA2EVF4LC sits in the 110 V AC/DC group with a red cap.

Code group Supply Colour digits in this lane
XA2EVF…LC 110 V AC/DC 4 red, 5 amber, 6 blue
XA2EVM…LC 220–230 V AC 3 green, 4 red, 5 amber, 6 blue, 8 yellow
XA2EVMD…LC 220 V DC 1 white, 3 green, 4 red, 6 blue
XA2EVQ…LC 380–400 V AC 1 white, 5 amber, 6 blue

Selection checklist and RFQ information for XA2EVF4LC

For a clean enquiry, send the information below. It lets us confirm the part number against the datasheet and check availability without a second round of questions.

  • Part number XA2EVF4LC and the required quantity.
  • The control supply: confirm 110 V AC or DC, 50/60 Hz and whether it is AC or DC.
  • The lamp colour and its meaning in your panel legend.
  • Panel thickness and material at the fixing hole, to match the 1 to 6 mm or 2 to 6 mm window.
  • Rear clearance behind the panel, against the 53 mm body depth.
  • Required markings or approvals for the project, so that we can compare them with the datasheet listing.
  • Delivery location in Oman or the GCC and any required lead time.

If you are replacing an existing indicator, a photo of the old lamp and its rating label is the fastest way to confirm a like-for-like match.

Mounting, cut-out and wiring of the XA2EVF4LC

The XA2EVF4LC mounts in a round fixing hole of 22.5 mm with a tolerance of 0.2 mm in either direction, in line with IEC 60947-5-1. The datasheet recommends a fixing centre of at least 30 × 40 mm and quotes a panel thickness of 1 to 6 mm for metal and 2 to 6 mm for plastic. A single nut beneath the head clamps the unit, and the recommended tightening torque is 2.2 N.m with a tolerance of 0.2 N.m. Over-tightening can distort a thin panel and spoil the seal, so use a torque tool on the first panel of a batch.

Connection of XA2EVF4LC is by screw clamp terminals. The datasheet allows up to two conductors of 1.5 mm² with cable ends, or a single conductor from 0.5 to 2.5 mm² without ends, and the screw heads accept a Philips No 2 driver or a flat 4 mm or 5.5 mm blade. The terminals are marked X1 and X2, and the overall body is 29 mm wide and 29 mm high with a depth of 53 mm behind the panel, so check the space behind the door before stacking a row of lamps close to a busbar or a terminal rail.

Installation, commissioning and maintenance notes

Before energising XA2EVF4LC, confirm that the supply on its terminals is the rated value and not a higher panel voltage, and that no neighbouring wiring is pinching the rear terminals. Switch on and check that this unit lights at the right moment in the sequence, then check that it is fully dark when the circuit is de-energised, which also confirms that the anti-interference design is doing its job on your cable length.

Where a red lamp belongs on the panel

Red is the colour operators watch for first, and standards-minded panel builders reserve it for faults, trips, danger and emergency conditions, or for a stopped state when the plant specification says so. Using red for a harmless indication dilutes its meaning, so check the project colour table before assigning this lamp to a duty. The this unit follows this red convention.

Typical uses in Oman and the GCC

Indicators of this class, including this unit, turn up on motor control centres, pump and fan starters, water treatment skids, switchgear doors and packaged equipment panels throughout the region. In oil and gas and petrochemical sites they appear on auxiliary panels and local control stations; in power and desalination plants they mark pump status, valve position and supply healthy. Municipal buildings, cold stores and workshops use them on distribution boards and machine panels.

Documents and quotation

The Schneider Electric datasheet for the XA2EVF4LC is attached on this page for your technical file. It lists the electrical, mechanical and environmental data summarised above.

To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please confirm that the datasheet data suits your project before ordering.

Datasheets & Documents
  • PDF Datasheet Schneider Electric XA2EVF4LC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric XA2EVF4LC Red 110 V AC/DC LED

Answers from our engineering team on installation, compatibility and integration.

01Is the XA2EVF4LC an AC or DC lamp?
The datasheet lists the rated supply as 110 V AC or DC, 50/60 Hz. It accepts both AC and DC, so one lamp covers either supply type.
02Can the lamp bulb of the XA2EVF4LC be replaced?
No. The datasheet describes a monolithic pilot light with an integral clustered LED and no bulb base, so a failed unit is replaced as a whole.
03What panel hole does the XA2EVF4LC need?
A round hole of 22.5 mm with a tolerance of 0.2 mm, in a panel 1 to 6 mm thick for metal or 2 to 6 mm for plastic, held by a nut tightened to 2.2 N.m.
04What protection rating is listed for the XA2EVF4LC?
The datasheet lists IP65 under IEC 60529 and IK05, with operation from -25 to 70 °C and storage from -40 to 70 °C.
05Does Seven Star LLC supply the XA2EVF4LC in Oman?
Yes, Seven Star LLC supplies it as an independent supplier in Muscat for Oman and the GCC. Send the part number and quantity and we confirm availability and documents.