Schneider Electric DBV31830MS DBSeT VTPN 18+30-Way 125A Board

Description

DBV31830MS: VTPN DBSeT 18 + 30-way surface-mount three-phase board

The DBV31830MS is a Schneider Electric VTPN distribution board in the DBSeT range, a two-bank three-phase 125 A board with 18 + 30 outgoer ways. The datasheet describes a distribution enclosure for low-voltage electrical distribution, supplied with a pan assembly, earthing bar and neutral bar behind a plain flat door, in the surface-mounting version. Seven Star LLC supplies the DBV31830MS in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference from its title and datasheet, DBV3 is the three-phase VTPN group, the digits that follow give the outgoer way count of each bank, and the closing letters MF or MS carry the modular 125 A incomer with flush or surface mounting. This is our reading of the naming and not a published ordering key, so rely on the datasheet for anything binding.

Comparing the DBV31830MS with its siblings

The table lists each surface-mount double-bank 125 A board of the DBV group with the figures from its datasheet.

Reference Outgoer ways W × H × D (mm) Packed weight
DBV31818MS 18 + 18 425 × 785 × 124.9 17.43 kg
DBV31824MS 18 + 24 425 × 785 × 124.9 18.27 kg
DBV31830MS 18 + 30 425 × 855 × 124.9 19.845 kg

Rating, voltage and short-circuit values stay constant in this group while way count, height and weight rise.

Selection checklist and RFQ information for DBV31830MS

  • Confirm a three-phase 240–415 V AC, 50/60 Hz supply and a maximum of 125 A.
  • Compare the prospective fault level with 17 kA for 0.25 s and 34 kA peak.
  • Count outgoers against 18 + 30 ways and allow for multi-pole devices and spares.
  • Verify wall space or recess for 425 × 855 × 124.9 mm and the surface mounting.
  • Decide on the incomer: an isolator with RCCB, and whether devices are quoted with the board.

For the RFQ please send the reference, quantity, delivery location, project name and a draft circuit schedule if available.

Surface mounting of the DBV31830MS

The surface version fixes to the wall face, so nothing needs to be cut and the full 124.9 mm depth stays in the room. The enclosure measures 425 × 855 × 124.9 mm (W × H × D), the packed weight is 19.845 kg and the carton measures 85.5 cm by 42.5 cm by 12.49 cm. Check that the wall construction can carry that load with proper fixings.

Cables enter through the removable gland plate at the top and bottom, so surface trunking or conduit can arrive from either direction. The flush twin is the DBV31830MF, listed at 855 mm height and 19.845 kg packed weight; read the datasheet of the exact reference because the figures are not always identical.

Installing and maintaining the DBV31830MS

The enclosure is painted sheet steel, 1.2 mm thick, finished in White (RAL 9003), rated IP41 under IEC 60529 and IK08, for an ambient operating temperature of 50 °C. IP41 means indoor, dry rooms; it does not cover splash, outdoor or heavy dust exposure.

The DBV31830MS ships as an enclosure with pan assembly and bars, so the electrician fits the incomer and outgoer devices on site, connects neutral and earth to their bars, labels each way and tightens terminals to the device torque values. Test RCDs, record readings in the commissioning file and use thermal imaging under load during service to find loose connections. The datasheet lists an 18-month warranty.

Where the DBV31830MS fits in Oman and the GCC

A 125 A modular incomer suits a floor or a smaller building: apartments, retail units, offices, site accommodation and utility rooms across Oman and the GCC. Typical loads are lighting, air-conditioning units, pumps and small machines on 48 outgoer ways.

Summer heat is the main stress. Compare the 50 °C ambient limit and the IP41 rating with the real room, because an air-conditioned electrical room is generally suitable while a roof cabinet or unventilated cabin in direct sun may not be. Mention dust and humidity when you enquire.

How the 18 + 30 bank layout works in practice

A 18 + 30 board splits its outgoers into two ranks. The first rank of 18 ways sits alongside the incoming device and the second rank of 30 ways continues below, which keeps the enclosure at 425 mm width and pushes the growth into height, now 855 mm. That is why the double-bank references are the tall members of the family while staying as shallow as the 125 A single-bank boards.

The previous size in this mounting style is the DBV31824MS with 18 + 24 ways, and it is the largest, so additional circuits need a second board. As with all module-based boards, a multi-pole device uses more than one position, so the real number of circuits is below 48.

Technical specifications of the DBV31830MS

Parameter Specification
Manufacturer / part number Schneider Electric / DBV31830MS
Range DBSeT (VTPN)
Product type Distribution board, distribution enclosure
Application Low voltage electrical distribution
Number of ways 18 + 30 (outgoer)
Rated current [In] 125 A
Rated voltage 240–415 V AC 50/60 Hz
Network 3 phases
Rated short-time withstand [Icw] 17 kA for 0.25 s
Rated peak withstand [Ipk] 34 kA
Rated impulse withstand [Uimp] 6 kV
Rated insulation voltage [Ui] 500 V AC
Incomer device Isolator + RCCB (incomer)
Outgoer devices MCB; RCBO
Provided equipment Pan assembly, earthing bar, neutral bar, enclosure
Mounting Surface
Door Plain flat door
Cable entry Removable gland plate at top and bottom
Material / colour Painted sheet steel 1.2 mm thick / White (RAL 9003)
Width / height / depth 425 / 855 / 124.9 mm
IP / IK IP41 conforming to IEC 60529; IK08
Operating ambient temperature 50 °C
Standards IEC 61439-3, IEC 61439-1
Product certification DEKRA
Packed weight 19.845 kg
Package size (L / W / H) 85.5 cm / 42.5 cm / 12.49 cm
Warranty 18 months

Incomer arrangement and ratings of the DBV31830MS

The DBV31830MS is a 125 A board at 240–415 V AC, 50/60 Hz, three phases, with the same 17 kA for 0.25 s short-time withstand current (Icw), 34 kA peak (Ipk), 6 kV impulse and 500 V AC insulation values as the single-bank boards of its family. The standards are IEC 61439-3 and IEC 61439-1.

The protection options listed for this double-bank version are an isolator with RCCB as the incomer and MCBs and RCBOs as outgoers. Unlike the smaller references, the isolator-only and RCCB-only incomer entries are not listed here, so a plan that depends on those should be checked against the datasheet. The ways are given as 18 + 30, which means the pan assembly carries a first bank of 18 ways and a second bank of 30, 48 outgoer ways in total.

Documents and quotation

An official datasheet for the DBV31830MS is attached on this page. It carries the electrical ratings, enclosure details, packing data and environmental profile summarised above.

To request a quotation, send the part number, quantity and delivery location. Seven Star LLC will confirm lead time and commercial terms and can quote related devices with the board.

Other Models in the Se Dbset Dbv Dbl Range

Seven Star LLC supplies models from the Se Dbset Dbv Dbl range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric DBV31818MF DBSeT VTPN 18+18-Way 125A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBV31818MS DBSeT VTPN 18+18-Way 125A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBV31824MF DBSeT VTPN 18+24-Way 125A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBV31824MS DBSeT VTPN 18+24-Way 125A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBV31830MF DBSeT VTPN 18+30-Way 125A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBV31830MS DBSeT VTPN 18+30-Way 125A BoardSwitchgear, Enclosures & DistributionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric DBV31830MS Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric DBV31830MS DBSeT VTPN 18+30-Way

Answers from our engineering team on installation, compatibility and integration.

01What incomer does the DBV31830MS take?
The datasheet lists an isolator with RCCB as the incomer, within the 125 A rating of the board.
02What short-circuit ratings are listed for the DBV31830MS?
The datasheet gives 17 kA for 0.25 s (Icw) and 34 kA peak (Ipk), with 6 kV impulse withstand and 500 V AC insulation voltage. Compare them with the prospective fault level at site.
03How many outgoer ways does the DBV31830MS have?
The datasheet lists 18 + 30 ways (outgoer), 48 single-pole positions in total. Multi-pole breakers and RCBOs take more than one position.
04Does the DBV31830MS include breakers?
No. The listed equipment is a pan assembly, earthing bar, neutral bar and enclosure, so the incomer, MCBs and RCBOs are fitted separately.
05How is the DBV31830MS installed and where?
It is fixed on the wall surface, rated IP41 and IK08 with a 50 degC ambient limit, so it is for indoor dry rooms. The enclosure is 425 by 855 by 124.9 mm.