Panametrics M Series (M1/M2) Aluminum Oxide Moisture Probe

Description

Panametrics M Series overview

The Panametrics M Series is the long-running aluminum oxide moisture probe family, available as the M1 with a flange process connection and the M2 with a threaded process connection. The manufacturer states that Panametrics aluminum oxide probes have set the standard in industrial moisture measurement for more than 40 years. Probes connect to Panametrics hygrometer consoles through an interconnecting cable, and many installed M Series probes are still in service, which is why replacements and recalibrated spares are frequently requested.

For buyers in Oman and the wider Gulf, the M Series is a part that is searched for by exact model name, because the equipment it belongs to often stays in service for many years. This page describes the M Series aluminum oxide moisture probe using only information published by the manufacturer, so that you can confirm the model before you send a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the Panametrics M Series

The manufacturer highlights the following points for the M Series.

  • True absolute humidity response rather than relative humidity response.
  • Intrinsically safe when used with certified electronics or zener barriers.
  • Individually computer calibrated against moisture concentrations traceable to national standards.
  • Cable length to the hygrometer of 2000 ft (610 m) or more.
  • Optional NTC thermistor temperature sensor.
  • Works in gases and non-aqueous liquids from trace to ambient levels.
  • Suited to in situ mounting or to sample conditioning systems with general purpose, Type 4 or Type 7 sample cells.

Together these points explain why the M Series remains a practical choice where the measurement must be dependable and where service access is limited. Each statement above comes from the published datasheet, and nothing has been added beyond it.

Technical specifications of the M Series

Parameter Value
Sensor type Aluminum oxide moisture sensor
Overall dew/frost point capability 60 to -110 C (140 to -166 F) by request
Standard calibration range 10 to -80 C (50 to -112 F), data from 20 to -110 C
Ultralow calibration range -50 to -100 C, data to -110 C
Accuracy 2 C above -100 C; 3 C below -100 C
Repeatability 0.2 C above -100 C; 0.5 C below -100 C
Pressure, M1 flange 5 micron Hg to 75 psig (6 bar)
Pressure, M2 threaded 5 micron Hg to 5000 psig (345 bar)
Gas flow Static to 10,000 cm/s linear velocity at 1 atm
Liquid flow Static to 10 cm/s at 1 g/cc density
Operating temperature -20 to 60 C
Storage temperature -30 to 70 C
Input 1 VAC, 77 Hz
Optional temperature sensor NTC thermistor, -30 to 70 C, 0.5 C overall accuracy
Approvals ATEX II 1 G EEx ia IIC T4; CSA Class I Div 1 Groups A-D T4

Values are taken from the manufacturer datasheet for the M Series; always confirm against the current document, because ranges, certifications and options depend on the exact configuration that is ordered.

Typical applications for the M Series in Oman and the GCC

The M Series is applied in natural gas dehydration and pipeline gas, petrochemical streams, industrial gas, furnace and heat treating gas, power generation and air dryers.

In oil and gas, the M Series supports process monitoring where an accurate reading helps operators protect equipment and keep production stable. In utilities and water, it gives plant teams a measurement they can trust for balance and efficiency checks. In general manufacturing, it is used wherever the process fluid or gas has to be controlled closely. The hot climate and demanding duty of the region put extra weight on dependable instruments, so spare availability of the M Series matters to maintenance planners.

Selection and compatibility notes for the M Series

Choose M1 when a flanged connection at modest pressure is wanted and M2 when a threaded connection at pressures up to 5000 psig is required. The calibration range, with or without the temperature sensor, is set at ordering. Sample conditioning is advisable when conductive or erosive particles are present. Quote the existing probe serial number and the analyzer it connects to.

If you are replacing an existing M Series, the safest approach is to read the nameplate, note the full model code, serial number and any certification marking, and send those details with your enquiry. This avoids mismatches in mounting, connector or range, which are the most common causes of a replacement that does not fit.

Installation and commissioning of the M Series

Follow the installation guide or user manual that belongs to your meter or analyzer. Before fitting the M Series, check that the process conditions, including temperature, pressure and fluid, are inside the limits in the specification table. Confirm the cable or connector type, use the recommended wiring and keep signal cables away from power cabling. After mounting, verify the reading against a known reference or an expected process value and record the configuration so that later maintenance can repeat it. In hazardous areas, install only with the certified accessories and follow the local code of practice.

Maintenance and service life of the M Series

Routine care for the M Series consists of visual inspection of the connector, cable, seals and mounting hardware, checking the reading for drift or noise, and keeping the surface free of deposits where that applies to the design. Keep a spare on the shelf for critical measurements, since lead times for specialist parts can be long. Recalibration or exchange intervals should follow the manufacturer recommendation for the instrument system in which the M Series operates.

Related products and ordering notes for the M Series

The M Series is one member of the wider Panametrics range of flow, moisture, oxygen and gas measurement equipment. Related items on this site include other Panametrics analyzers and flow meters. When ordering, give the exact part or model code, the quantity, the meter or analyzer it will connect to and the delivery location. Do not rely on the family name alone, because the M Series family has several configurations.

Frequently asked questions about the M Series

The questions below summarize what buyers most often ask about the Panametrics M Series: what it is, where it is used, which conditions it handles and how to order a matching part. The answers are drawn from the published datasheet. For anything that depends on a specific configuration, send us the nameplate data and we will help confirm the match before quoting.

Documents and quotation

A manufacturer datasheet for the M Series is attached to this page. To request a quotation, send the RFQ with the part number M Series, the full model code from your nameplate and the quantity you need, and our team will respond with availability and lead time. M Series enquiries from Oman and the GCC are welcome.

Datasheets & Documents
  • PDF Datasheet Panametrics M Series (M1/M2) Aluminum Oxide Moisture Probe Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics M Series (M1/M2) Aluminum Oxide

Answers from our engineering team on installation, compatibility and integration.

01What is the Panametrics M Series?
The Panametrics M Series is a aluminum oxide moisture probe (M1 flange and M2 threaded). It is described in the manufacturer datasheet referenced on this page.
02Where is the M Series typically used?
The datasheet and application notes point to uses such as natural gas dehydration and pipeline gas and similar process duties.
03What are the key specifications of the M Series?
Sensor type: Aluminum oxide moisture sensor; Overall dew/frost point capability: 60 to -110 C (140 to -166 F) by request. See the specifications table for the full list.
04How do I make sure I order the correct M Series?
Send the full model code, nameplate details and the instrument it connects to. Many Panametrics items are configured by code, so every field must match.
05Is Seven Star LLC affiliated with the manufacturer of the M Series?
No. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number and quantity.