- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: MICHELL Instruments
Michell MDM300-STD Portable Dew-Point Hygrometer
Description
Michell MDM300-STD portable dew-point hygrometer overview
The Michell MDM300-STD is the general-purpose version of the MDM300 advanced portable hygrometer, a hand-held instrument built for fast spot checks of dew point in compressed air, natural gas, switchgear quench gas and other industrial gases. It is the safe-area model of the pair: it carries CE and UKCA marking but no hazardous-area coding, which is exactly why it reaches -60 °C dew point faster than its intrinsically safe sibling. Michell states a T95 response of 15 minutes or less to -60 °C (-76 °F) dew point at low pressure, and no waiting period is required between consecutive measurements, so a technician can walk a plant and log many points in one shift.
Inside the polyamide housing is Michell’s ceramic metal-oxide sensor. A porous top electrode, a hygroscopic insulating layer and a base electrode sit on a ceramic substrate; the active layer is under one micron thick and the porous outer layer under one nanometre. Water vapour adsorbs into the sandwich and changes its impedance, which the electronics convert to dew point. Because this MDM300-STD ships with a 13-point calibration certificate taken over a ten-day cycle and traceable to NPL (UK) and NIST (USA), the readings can also be used to verify Easidew transmitters in service.
This page covers the part number MDM300-STD only. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of MDM300-STD
- Accuracy of ±1 °C (±1.8 °F) dew point from -60 to +20 °C, widening to ±2 °C from -100 to -60 °C, with temperature accurate to ±0.2 °C.
- Display units of °C, °F and K for dew point and gas temperature, plus ppmV, ppmW, % RH, g/m3 and g/kg for air, nitrogen, CO2 and SF6.
- Up to 48 hours of typical use from the 4.8 V NiMH pack, charged by the intelligent charger that is supplied.
- 8 MB data logger with a 5 to 60 second interval and up to 10,000 entries per log file, read out over Bluetooth version 2.0 at up to 5 m.
- IP66 and NEMA 4 enclosure in steel-fibre-loaded high-impact polyamide 6, weighing 1.35 kg.
- Blue graphical LCD with menus in English, French, German, Italian, Portuguese and Spanish, and large buttons usable with gloves.
MDM300-STD technical specifications
| Part number | MDM300-STD |
| Sensor technology | Michell ceramic metal-oxide moisture sensor |
| Accuracy, dew point | ±1 °C from -60 to +20 °C; ±2 °C from -100 to -60 °C |
| Calibrated range, spot checks | -70 to +20 °C dew point |
| Calibrated range, online analysis | -100 to -70 °C dew point |
| Uncalibrated readings | +20 to +30 °C dew point |
| Response | T95 in 15 minutes or less to -60 °C dew point |
| Operating pressure | 350 barg (5076 psig) maximum |
| Flow across sensor | 0.2 to 1.2 Nl/min |
| Gas connections | 1/8 inch NPT female (other options available) |
| Gas-wetted material | AISI 316L stainless steel |
| Operating and storage temperature | -20 to +50 °C |
| Battery | NiMH 4.8 V, up to 48 hours typical |
| Enclosure | IP66 / NEMA 4, polyamide 6 |
| Dimensions (d x w x h) | 218 x 170 x 90 mm |
| Weight | 1.35 kg |
| Data logging | 8 MB, 5 to 60 s interval, up to 10,000 logs per file |
How MDM300-STD differs from other MDM300 variants
The only other base model in the family is the MDM300-IS, and the numbers separate them clearly. MDM300-STD reaches T95 at -60 °C in 15 minutes or less where the I.S. unit needs 30; it runs 48 hours on a charge against 24; its flow window is 0.2 to 1.2 Nl/min against 0.2 to 0.5 Nl/min; and it weighs 1.35 kg against 1.5 kg. Its wetted parts are stainless steel only, while the I.S. version adds a PTFE seal, borosilicate glass and ceramic. Choose MDM300-STD whenever the sample point is outside a classified zone and speed matters; choose the I.S. model when a Zone 0 or Class I Division 1 certificate is required by the site.
Typical applications for MDM300-STD in Oman and the GCC
Compressed-air and desiccant-dryer audits are the obvious use: connect to the dryer outlet through the 1/8 inch NPT port and read pressure dew point at up to 350 barg. In gas processing plants the same unit can verify dehydration performance at a metering skid, while utilities use it on SF6 and other quench gases in high-voltage switchgear. Water-treatment and manufacturing sites with nitrogen or oxygen generators benefit from the ppmV scale, and medical-gas and metallurgical users can check purity lines without taking an analyzer offline. Michell also lists industrial gas production and transport and petrochemical refineries among its target applications.
Selecting accessories and sampling for MDM300-STD
The base instrument is only half of a working kit. Order codes in the manufacturer’s list include the MDM300-STD-BAG carry bag, the MDM300-CASE hard case, fittings packs (MDM300-2PK-FIT-A to D) that convert 1/8 inch NPT to Swagelok or Legris connectors, flexible tubing in 0.5 m and 1.8 m lengths, and the MDM300-SPA sample pump assembly powered through the external sensor connector. For pressure compensation there are external pressure transmitters in 10, 40, 100 and 400 barg ranges with 2 m or 5 m cables, and an Easidew EA2-TX external dew-point sensor with MDM-DP-SC02 and MDM-DP-SC05 leads. Spares include the MDM300-CHA charger, orifice and Dowty seal kits, MDM300-BAT-STD battery pack and the MDM300-SEN calibrated sensor assembly.
Setting up and commissioning MDM300-STD
Before the first use, charge the pack fully and confirm the language, units and logging interval from the menu. Fit the correct adaptor for the sample point, purge the line, and connect so that gas passes the sensor at 0.2 to 1.2 Nl/min through the orifice. At low pressure expect the long dry-down to -60 °C. Take the reading only when the trend is flat, then store it in the log and move to the next point. Bluetooth transfer of logs needs a paired laptop within 5 m and the optional MDM300-DONGLE if the laptop has no Bluetooth.
Care, calibration and service of MDM300-STD
Keep the sample path dry between jobs; the case is rated IP66, but moisture left in the orifice lengthens the next dry-down. Replace seals when the orifice or Dowty seal shows wear. For calibration continuity, the manufacturer lists a service-exchange sensor assembly (MDM300-SEN-X) returned within 21 days, a 13-point recalibration of the MDM300-STD between -100 and +20 °C dew point, and an option to record readings before adjustment.
Frequently asked questions on MDM300-STD
Buyers usually ask three things: is the unit hazardous-area rated (no, use MDM300-IS), how fast is the response (T95 within 15 minutes to -60 °C at low pressure), and what pressure it handles (350 barg maximum with suitable sampling). Another common question is whether it can check fixed transmitters; the datasheet says the MDM300 series can verify and recalibrate Michell Easidew dew-point transmitters.
Documents and quotation
The manufacturer’s MDM300 datasheet is attached to this page as a PDF and covers both the standard and I.S. versions. To receive a quotation for MDM300-STD, send an RFQ with the part number, the quantity, the gas types and pressures involved, and any accessories such as the carry case, sample pump or external pressure transmitter. Lead time and availability are confirmed on request.
Other Models in the Michell Mdm300 Range
Seven Star LLC supplies models from the Michell Mdm300 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell MDM300-IS Intrinsically Safe Portable Hygrometer | Humidity & Dew Point Instruments | View details |
| Michell MDM300-STD Portable Dew-Point Hygrometer | Humidity & Dew Point Instruments | You are viewing this model |
Datasheets & Documents
- Datasheet Michell MDM300-STD Portable Dew-Point Hygrometer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell MDM300-STD Portable Dew-Point Hygrometer
Answers from our engineering team on installation, compatibility and integration.
01Is MDM300-STD certified for hazardous areas?
No. The MDM300-STD carries CE and UKCA marking only. The I.S. certificates (ATEX, IECEx, cQPSus) in the datasheet apply to the separate MDM300-IS model.
02How quickly does MDM300-STD reach -60 °C dew point?
The datasheet gives a T95 of 15 minutes or less to -60 °C (-76 °F) dew point at low pressure, compared with 30 minutes for MDM300-IS.
03What pressure can MDM300-STD measure at?
The maximum operating pressure is 350 barg (5076 psig). The standard gas connection is 1/8 inch NPT female, and flow across the sensor should be 0.2 to 1.2 Nl/min.
04How long does the MDM300-STD battery last?
The 4.8 V NiMH pack gives up to 48 hours of typical use between charges, and an intelligent charger is supplied with the instrument.
05Can MDM300-STD log and export readings?
Yes. It stores 8 MB of data with a 5 to 60 second interval and up to 10,000 logs per file, and sends data wirelessly over Bluetooth version 2.0 within about 5 m.


















Reviews
There are no reviews yet.