Description
Michell OPT501 overview: wall mount chilled mirror hygrometer or transmitter
Michell OPT501 is the parent order code of the Michell Optidew 501, the wall-mount version of the Optidew chilled mirror hygrometer. The order-code sheet lists four case choices: wall mount with display, wall mount with display IP65 (RS485 only), wall mount transmitter, and wall mount transmitter IP65 (RS485 only).
The datasheet describes the 501 as a blind transmitter version of the instrument and gives the same sensor performance as the OPT401: plus or minus 0.15 degrees Celsius dew point accuracy with dew-point ranges that depend on the sensor.
Plants choose Michell OPT501 when the instrument is mounted in a plant room or on a wall and reads out to a control system.
The image shows the Optidew instruments and sensor from the manufacturer datasheet.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list OPT501 so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of OPT501
- Wall-mount chilled mirror hygrometer with display or as a blind transmitter.
- IP65 case options, restricted to RS485 communications.
- Sensor choices: single stage POM, two stage POM, or harsh environment PEEK head.
- Dew-point accuracy plus or minus 0.15 degrees Celsius; two 0/4 to 20 mA outputs and RS485 communications.
- Optional pressure transmitter for ppmV and g/kg calculations.
- Supply 100 to 240 V AC.
OPT501 technical specifications
The table below lists values published by the manufacturer for the product family of OPT501. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | OPT501, Optidew 501 chilled mirror hygrometer |
| Case options | Wall mount with display; IP65 with display; transmitter; IP65 transmitter |
| Dew-point accuracy | Plus or minus 0.15 degC |
| Dew-point range | Minus 25 to plus 90 degC (single stage); minus 40 to plus 90 degC (dual stage); minus 40 to plus 120 degC (harsh environment) |
| Analog outputs | Two 0/4 to 20 mA, maximum load 500 ohm |
| Supply voltage | 100 to 240 V AC |
| Ingress protection | IP54 standard; IP65 optional |
| Sensor pressure | 2500 kPa maximum |
Typical applications of OPT501 in Oman and the GCC
- Environmental monitoring in clean rooms.
- Coating process monitoring and humidity control for metallurgical processes.
- HVAC testing and chamber monitoring.
In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as OPT501 is usually specified against a defined dew-point or ppmV target and a documented calibration.
Selection and compatibility notes
The OPT501 order string selects case (A to D), sensor, calibration and cable length. Choose a transmitter version if a local display is not needed, and the IP65 versions when washdown or dust are present, noting the RS485-only restriction.
Confirm four things before ordering OPT501: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.
Installation and commissioning of OPT501
Wall mount the unit in the plant area and run the dew-point sensor cable using the standard or high temperature cable options listed on the order-code sheet.
Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.
Maintenance, calibration and service
Mirror cleaning kit CM-CLN-KIT, spare sensors OPT2-STD-1, OPT2-STD-2 and OPT2-HES-2, and cables OPT2-DPSC-03 to OPT2-DPSC-20 are listed as spares.
Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.
Related products and ordering notes for OPT501
- OPT401: bench top version.
- OPT2-STD-2: two stage dew-point sensor.
- OPT2-HES-2: harsh environment two stage sensor.
When you request OPT501, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about OPT501
- What is OPT501? OPT501 is the manufacturer parent code for the Optidew 501 wall-mount chilled mirror hygrometer, available with display or as a transmitter.
- What does OPT501 suit? It suits reference-grade dew-point measurement in fixed installations, clean rooms and process humidity control.
- What case versions does OPT501 have? The order code lists wall mount with display, wall mount with display in IP65, wall mount transmitter, and wall mount transmitter in IP65.
- What should I send with an RFQ for OPT501? Send the part number OPT501, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of OPT501 and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number OPT501, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for OPT501 in writing.
Other Models in the Michell Optidew Range
Seven Star LLC supplies models from the Michell Optidew range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell OPT401 Optidew 401 Chilled Mirror Hygrometer | Humidity & Dew Point Instruments | View details |
| Michell OPT501 Optidew 501 Wall Mount Chilled Mirror Hygrometer | Humidity & Dew Point Instruments | You are viewing this model |
Datasheets & Documents
- Datasheet Michell OPT501 Optidew 501 Wall Mount Chilled Mirror Hygrometer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell OPT501 Optidew 501 Wall Mount Chilled
Answers from our engineering team on installation, compatibility and integration.
01What is OPT501?
OPT501 is the manufacturer parent code for the Optidew 501 wall-mount chilled mirror hygrometer, available with display or as a transmitter.
02What does OPT501 suit?
It suits reference-grade dew-point measurement in fixed installations, clean rooms and process humidity control.
03What case versions does OPT501 have?
The order code lists wall mount with display, wall mount with display in IP65, wall mount transmitter, and wall mount transmitter in IP65.
04Can Seven Star LLC supply OPT501 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for OPT501?
Send the part number OPT501, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.