Brand: MICHELL Instruments
MICHELL Instruments XZR200 Zirconium Dioxide Oxygen Analyzer
Description
Overview
The MICHELL Instruments XZR200 is a low-cost zirconium dioxide oxygen analyzer in a die-cast aluminium case, supplied with a stainless steel probe of 210 mm or 400 mm. It can be set to read 0 to 25 percent or 0 to 100 percent oxygen, which lets one product cover both flue gas work and oxygen-rich or inert atmosphere checks. Sample temperatures up to 400 degrees Celsius are accepted, and the T90 response is under five seconds. Seven Star LLC is an independent supplier serving Oman and the GCC.
Why choose the MICHELL Instruments XZR200
- Two calibrated ranges, 0 to 25 and 0 to 100 percent oxygen, selected at order stage.
- Outputs of 4-20 mA and 0 to 10 V DC, or an RS232 interface (RS232 is not available when the 4-20 mA output is selected).
- A cycling 3.3 V DC logic output lets a control system watch the sensor directly for diagnostics.
- Calibration can be carried out in normal air at 20.7 percent oxygen or in any other known oxygen concentration, and can be triggered manually or by an external signal.
- Selectable output filtering gives either fast dynamic response or slow stable readings.
- IP65 die-cast housing, stainless steel wetted parts and a 12 mm Swagelok compression fitting or equivalent.
MICHELL Instruments XZR200 technical specifications
| Measurement technology | Zirconium dioxide |
|---|---|
| Range | 0-25 percent or 0-100 percent oxygen |
| Accuracy | Less than 0.5 percent O2 (0-25 percent); less than 1 percent O2 (0-100 percent) |
| Response time (T90) | Less than 5 seconds |
| Repeatability | Less than 0.5 percent |
| Sample flow rate | 0 to 10 m/s; flow effect plus or minus 0.1 percent O2 from 0 to 1 l/min |
| Sample temperature | Up to +400 C (752 F) |
| Sample pressure | Atmospheric; 0 to 25 percent measurable to 3 barg without damage, with recalibration |
| Background gas | Air, N2, CO2, Ar or combustion gas |
| Power | 24 V DC, plus or minus 10 percent, 500 mA maximum |
| Analog outputs | 4-20 mA and 0 to 10 V DC |
| Digital | RS232 (not with 4-20 mA output) |
| Ambient temperature | -10 C to +85 C |
| Warm-up time | About 10 minutes, including stabilization |
| Dimensions | 52 x 75 x 80 mm (h x w x d) excluding probe |
| Probe | 210 or 400 mm long, 12 mm diameter |
| Weight | Less than 0.5 kg |
| Process connection | 12 mm Swagelok compression fitting or equivalent, weld socket supported |
| Ingress / housing | IP65, waterproof die-cast aluminium |
Electrical and signal details
The analyzer runs from 24 V DC within plus or minus 10 percent and draws no more than 500 mA, so a small instrumentation supply is adequate. Output resolution is 0.01 V, 0.01 mA or 0.01 percent O2, and both ranges can be scaled on the analog outputs. Because the digital RS232 port is unavailable when the 4-20 mA output is used, decide at the design stage whether the control system will read a current loop or a serial stream. The logic output toggles at 3.3 V DC while the sensor is working, which makes it easy to confirm sensor health from a PLC digital input without extra wiring.
For a purchase specification, write the model as MICHELL Instruments XZR200, followed by the required range, the 210 or 400 mm probe, and the output option, so that the supplier can confirm the exact build before quoting.
Applications in Oman and the GCC
The datasheet lists combustion control on oil, gas and biomass boilers, laboratory and building air quality monitoring including confined space personnel safety, and composting. In the Gulf region the compact size suits small package boilers and heaters, ventilation checks in utility tunnels and tank rooms, inerting verification where the background gas is nitrogen, carbon dioxide or argon, and waste treatment sites. The 0 to 100 percent option also helps with oxygen enrichment and purge monitoring.
How XZR200 differs from other Michell oxygen analyzers
- Probe temperature limit of 400 C, against 700 C for the XZR250 and up to 1400 C for the XZR500.
- Probe length of 210 or 400 mm, compared with 435 mm on the XZR250 and 0.4, 0.6 or 0.9 m on the XZR500.
- Ambient rating to +85 C and an IP65 case, in a package under 0.5 kg; the XZR250 head weighs 1.6 kg.
- Fastest response in the family: T90 under 5 seconds against under 15 seconds for the XZR250 and 20 seconds for the XZR500.
Use the XZR200 where gas is cooler than 400 C, atmospheric in pressure and clean enough for an open probe tip; select a sturdier model where dust, acid gas or higher temperature are present.
Installation and commissioning
Mount the 12 mm probe through a weld socket or compression fitting, keeping the case where the ambient temperature stays below 85 C. The recommended installation in the datasheet inclines the unit about 15 degrees so that moisture does not run toward the housing. Two 4.5 mm mounting holes are reached by removing the lid. Wire 24 V DC and the chosen output, observe that the probe tip becomes hot, and allow roughly 10 minutes for warm-up before reading. Calibrate in ambient air at 20.7 percent oxygen or with a known test gas.
Maintenance
With no consumable reference supply, maintenance consists of periodic calibration, keeping the probe tip free of deposits and checking the fitting for leaks. The diagnostic logic output is useful for catching a failing sensor before it drifts out of tolerance.
Related products and ordering notes
State the range, probe length and output type when asking for a price on XZR200. Other Michell oxygen analyzers are available on this site if the application is hotter or dustier.
Related items you may also need: Condumax CDP301 Portable Hydrocarbon Dew-Point Tester | Michell PSD-2-AC PSD2 Pressure Swing Dryer | Michell QMA401 Trace Moisture Analyzer | All MICHELL Instruments products.
For the MICHELL Instruments XZR200, keep the downloaded document together with your purchase order and commissioning records. Having the manufacturer reference available at installation time simplifies acceptance checks, supports later spare-part planning and gives maintenance staff a single place to confirm wiring, mounting and setup information.
Details needed to quote the MICHELL Instruments XZR200
The MICHELL Instruments XZR200 is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.
- Measuring range and the gas or sample the MICHELL Instruments XZR200 will analyse.
- Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
- Supply voltage and the mounting style required on site.
- Hazardous area classification of the installation location, if any.
- Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.
Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.
Documents and quotation
The datasheet for the XZR200 is attached on this page. For availability and lead time, send an RFQ to Seven Star LLC quoting the part number XZR200, the quantity, the probe length and the range, plus your destination in Oman or the GCC.
Other Models in the XZR Range
Seven Star LLC supplies models from the XZR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| MICHELL Instruments XZR250 Zirconia Oxygen Analyzer 0.1-25% O2 | Gas Analyzer Systems | View details |
| MICHELL Instruments XZR500 Combustion Control Oxygen Analyzer | Gas Analyzer Systems | View details |
| MICHELL Instruments XZR200 Zirconium Dioxide Oxygen Analyzer | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet MICHELL Instruments XZR200 Zirconium Dioxide Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the MICHELL Instruments XZR200 Zirconium Dioxide Oxygen
Answers from our engineering team on installation, compatibility and integration.
01Which oxygen ranges does the XZR200 offer?
The XZR200 is configurable to measure 0 to 25 percent or 0 to 100 percent oxygen, with accuracy below 0.5 percent O2 and below 1 percent O2 respectively.
02What probe lengths does the XZR200 come in?
Two probe lengths are available, 210 mm and 400 mm, both 12 mm in diameter and made of stainless steel for sample temperatures up to 400 C.
03What outputs does the XZR200 provide?
It offers 4-20 mA and 0 to 10 V DC analog outputs, or an RS232 interface; RS232 is unavailable if the 4-20 mA output is selected.
04How is the XZR200 calibrated?
It can be calibrated in normal air at 20.7 percent oxygen or in any other known oxygen concentration, with manual or externally triggered automatic calibration.
05What is the response time of the XZR200?
The datasheet gives a T90 response of less than 5 seconds, with warm-up of about 10 minutes and a selectable output filter for fast or stable readings.