MICHELL Instruments OptiCal Humidity Calibrator, 10-90% RH

Description

Overview

Relative humidity sensors drift, and a plant that relies on them needs a way to check them on site. The MICHELL Instruments OptiCal is a stand-alone, transportable humidity calibrator that generates 10 to 90 percent relative humidity at 10 to 50 degrees Celsius inside an insulated chamber, and it includes an integrated Optidew chilled mirror reference instrument traceable to national standards. It needs no external services other than mains power. Seven Star LLC is an independent supplier serving Oman and the GCC.

Main features of the MICHELL Instruments OptiCal

  • Five interchangeable ports accept sensor bodies from 5 to 25 mm diameter, so almost any brand or model of probe can be tested.
  • A four-zone fan-assisted Peltier arrangement controls chamber temperature for stability and minimum gradient.
  • Closed-loop humidity control proportionally mixes dry and saturated air.
  • Humidity and temperature set points can be set manually from the front panel or run automatically from supplied software, with logging and charting on a PC.
  • A colour-changing desiccant, visible through a window, signals when it needs recharging; recharge by heating in an oven at 150 C for 3 hours.

MICHELL Instruments OptiCal technical specifications

Generated humidity range 10 to 90 percent RH
Control element accuracy Within plus or minus 1 percent RH (10 to 70 percent RH); within plus or minus 1.5 percent RH (70 to 90 percent RH)
Humidity stability Plus or minus 0.2 percent RH (20 to 80 percent RH)
Temperature range +10 to +50 C; lowest set point 10 C below ambient
Temperature accuracy / stability Plus or minus 0.1 C / plus or minus 0.1 C
Ramp rate +20 to +40 C at 1.5 C per minute; +40 to +20 C at 0.7 C per minute
Reference accuracy Dew point plus or minus 0.2 C; temperature plus or minus 0.1 C
Units Dew point (C or F), percent RH, temperature, g/m3, g/kg, water activity aW
Outputs 4-20 mA or 0-20 mA analog, 500 ohm maximum; RS232 at 9600 baud; volt-free alarm contact 30 V, 100 mA
Probe ports Up to five, sensor body diameters 5 to 25 mm
Chamber 2000 cm3; 105 x 105 x 160 mm (w x h x d)
Display Two-line vacuum fluorescent display, set-point resolution 0.1
Supply 85 to 264 V AC, 47/63 Hz, 150 VA
Instrument dimensions / weight 290 x 520 x 420 mm (h x w x d); 20 kg (44 lb)

How the calibration is carried out

The chamber humidity is regulated by mixing flows of dry air from the desiccant dryer with saturated air from the water saturator, and a removable relative humidity sensor acts as the control element. The built-in chilled mirror reference measures the actual condition, so the sensor under test is compared with a traceable value. Response to a humidity or temperature step is typically quicker than 10 minutes in manual mode.

Why an on-site reference matters for the MICHELL Instruments OptiCal

Sending relative humidity probes away for calibration means weeks without them or a stock of spares. A transportable generator with its own traceable reference turns the check into a half-day job: the probe is inserted, the chamber is stepped through a few set points, and the deviation from the chilled mirror is recorded. Because the reference measures dew point directly, the comparison does not inherit drift from a secondary sensor. The temperature of the chamber is held within 0.1 C, so differences between probe and reference reflect the probe and not the chamber. Plant quality teams can therefore evidence compliance with their own calibration intervals.

Applications in Oman and the GCC

Humidity matters in HVAC commissioning, pharmaceutical storage, food and cold chain, paper and textile plants, data centres and laboratories across the region. A transportable calibrator lets a service company or metrology department check RH probes at the user site instead of shipping them abroad, which saves downtime in hot, humid coastal climates.

How OptiCal differs from other Michell calibration products

  • OptiCal generates humidity and temperature in a chamber for RH sensors; dew point generators such as the ADG400 supply dry gas at set dew points.
  • OptiCal contains its own Optidew reference; the S8000 and S4000 TRS are reference hygrometers without a generator.
  • At 20 kg with a 290 x 520 x 420 mm case it is transportable, unlike the larger S4000 TRS rack.

Operation and maintenance

Place the unit on a bench, fill the saturator reservoir with distilled water (the front level indicator shows when to top up), insert up to five sensors through the port adapters, and set the humidity and temperature. Apart from periodic calibration of the chilled mirror reference, no other maintenance is needed beyond desiccant recharge.

Programming set points

The supplied application software lets the user create calibration programs for time-based control of temperature and humidity set points and chart the reference data on a PC for analysis. This makes the MICHELL Instruments OptiCal suitable for repeated multi-point checks, for example 20, 50 and 80 percent RH at two temperatures, run unattended while the technician logs the results of each probe.

Allow the chamber to stabilise after each set point change before reading the probe; the datasheet quotes typical ramp rates of 1.5 C per minute on heating from 20 to 40 C and 0.7 C per minute on cooling back, and humidity follows after temperature settles. Keep probe cables short and sealed in the port adapters so that room air does not leak into the chamber and disturb the reference.

Related products and ordering notes

For a quotation on OptiCal, state the supply voltage, the number and size of probes to be calibrated, and whether automated set point programming is needed.

Related items you may also need: Michell EA2-TX Easidew 2-Wire Dew-Point Transmitter 5/8 UNF | Michell OPT501 Optidew 501 Wall Mount Chilled Mirror Hygrometer | Michell Ceramic Impedance Moisture Sensor Module MT119815157-PA | All MICHELL Instruments products.

Configuring the MICHELL Instruments OptiCal for your process

The MICHELL Instruments OptiCal is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.

  • Measuring range and the gas or sample the MICHELL Instruments OptiCal will analyse.
  • Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
  • Supply voltage and the mounting style required on site.
  • Hazardous area classification of the installation location, if any.
  • Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.

Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.

Documents and quotation

The datasheet for the OptiCal is attached on this page. To check availability, send an RFQ to Seven Star LLC with the part number OptiCal, the quantity and your destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet MICHELL Instruments OptiCal Humidity Calibrator, 10-90% RH Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the MICHELL Instruments OptiCal Humidity Calibrator,

Answers from our engineering team on installation, compatibility and integration.

01What humidity range does the OptiCal generate?
The OptiCal generates 10 to 90 percent RH over +10 to +50 C, with chamber stability of plus or minus 0.2 percent RH from 20 to 80 percent RH.
02What reference does the OptiCal use?
It has an integrated Optidew chilled mirror reference instrument with dew point accuracy of plus or minus 0.2 C, traceable to national standards.
03How many sensors can the OptiCal calibrate at once?
The chamber has up to five ports that take sensor body diameters from 5 to 25 mm through port adapters.
04How is the desiccant in the OptiCal recharged?
The colour-changing desiccant is recharged by heating it in a conventional oven at 150 C for 3 hours.
05What outputs does the OptiCal provide?
It provides 4-20 mA or 0-20 mA analog output, RS232 at 9600 baud and a volt-free alarm contact rated 30 V and 100 mA.