MICHELL Instruments S8000 HT Chilled Mirror Hygrometer, 95 C dp

Description

Overview

Most reference hygrometers stop at modest dew points, but humidity calibration baths and climatic chambers work well above them. The MICHELL Instruments S8000 HT is a high-precision, high-temperature chilled mirror hygrometer for standards laboratories that measures frost or dew point from minus 30 to plus 95 degrees Celsius with accuracy of plus or minus 0.1 C. It sits in a compact 19 inch, 4U case and is supplied with 2 m heat trace lines. Seven Star LLC is an independent supplier serving Oman and the GCC.

Highlights of the MICHELL Instruments S8000 HT

  • Stability of plus or minus 0.05 C dew point and reproducibility of plus or minus 0.05 C dew point.
  • External platinum resistance thermometer for relative humidity measurements, with 2 m cable (250 m maximum).
  • 5.7 inch colour touchscreen with customizable display, trend graph and fault warnings.
  • USB and Ethernet or RS485 connectivity, plus SD card datalogging.
  • Frost Assurance (FAST) and Dynamic Contamination Correction (DCC) for confidence in the condensate phase and a uniform condensate layer.

MICHELL Instruments S8000 HT technical specifications

Measurement range -30 to +95 C (-22 to +203 F) frost/dew point
Accuracy Plus or minus 0.1 C (0.18 F) dew point
Reproducibility / stability Plus or minus 0.05 C / plus or minus 0.05 C
Mirror Gold-plated copper; 4-wire Pt100, 1/10 DIN class B
Sample flow 250 to 1000 mL/min, 750 mL/min recommended
Sample gas pressure 0.5 barg (7.25 psig) maximum
Connections Quarter inch Swagelok tube inlet and outlets
Calculated units Percent RH, g/m3, ppmV, mixing ratio g/kg, wet bulb temperature, water vapor pressure, pressure converted dew point
Analog outputs 2 active mA outputs, 0-20 or 4-20 mA
Digital Modbus RTU over USB; Modbus TCP/IP over Ethernet or RS485
Relays 1 process relay and 1 alarm relay, Form C, 1 A, 30 V DC
Data logging SD card, 8 GB supplied, up to 32 GB (FAT-32); 560 days at 2 s intervals
Optional pressure sensor 0 to 0.6 barg, accuracy within plus or minus 1 percent FS
Environmental conditions +10 to +30 C
Power 100 to 240 V AC, 580 VA
Dimensions / weight 480 x 440 x 185 mm; 22 kg (instrument), 26 kg with heat trace lines
Calibration 5-point UKAS calibration to +90 C dew point

Seeing what you measure: Frost Assurance

Moisture can exist as liquid water down to minus 30 C, and the condensation temperature difference between water and ice can reach 10 percent of the reading. Frost Assurance determines whether the sample dew point lies in the region where supercooled water can exist, and if so drives the mirror down to minus 30 C so ice is present on the surface. This removes ambiguity about the phase being measured.

Dynamic Contamination Correction

DCC adapts the instrument control automatically to guarantee a uniform condensate layer and repeatable measurement, and users can configure it for a given application. A barometric pressure transducer provides the real-time pressure input needed for pressure-derived values.

Operating principle of the MICHELL Instruments S8000 HT

The gas sample flows over a chilled, gold-plated copper mirror. At a temperature that depends on the moisture content and pressure of the gas, moisture condenses on the surface. An LED of constant intensity floods the mirror with light, and a photo detector measures the reflected light. Its output controls a thermoelectric heat pump to hold the condensation layer at constant thickness. At this equilibrium, where evaporation and condensation rates are equal, the Pt100 embedded in the mirror reads the dew point. The thermally compensated optics give exceptional sensitivity and fast response at high dew points, where many instruments struggle.

Tightly controlled heating and enhanced thermal stability allow the stated accuracy to hold even at elevated dew points, making the hygrometer a sensible choice for climatic chamber and humidity generator verification.

Applications in Oman and the GCC

The datasheet lists reference measurements in standards laboratories and humidity calibration facilities, reference duty in RH sensor manufacturing, and precision moisture measurement in research and development. Metrology institutes, test houses and calibration service providers in the Gulf can use it to verify climatic chambers and humidity generators across the warm, humid range.

How S8000 HT differs from other S8000 models and S4000 TRS

  • S8000 HT covers -30 to +95 C dew point; the S4000 TRS covers -100 to +20 C.
  • S8000 HT weighs 22 kg in a 4U case with touchscreen; S4000 TRS is an 85 kg mini rack.
  • S8000 HT includes heat trace lines and an external PRT for relative humidity, which low-frost-point models do not need.

Installation and use

Install in an environment between +10 and +30 C, keep sample pressure below 0.5 barg, and regulate flow near 750 mL/min through the quarter inch Swagelok ports. Use the supplied heat trace lines to prevent condensation in the sample line when the dew point is above ambient. Configure the touchscreen layout, the analog output scaling, alarm set points and the logging interval, and log to SD card for traceable records.

Maintenance

The instrument is delivered with a 5-point UKAS calibration. Keep the mirror clean and the sample line free of oil, use DCC settings that fit the gas quality, and schedule recalibration at the interval required by your laboratory scope.

Related products and ordering notes

For a quotation on S8000 HT, state the communication option (USB with Ethernet or RS485), the optional pressure sensor and the remote PRT cable length.

Related items you may also need: MDM300-SAM-PNL Panel Mounted Sampling System | Michell CD2-MON Condumax II Hydrocarbon Dew-Point Analyzer | Pura PUR-2W-M12 Ultra-Pure Moisture Transmitter, M12 | All MICHELL Instruments products.

When requesting a quotation for the MICHELL Instruments S8000 HT, mention whether you need a single unit or a quantity for several sites and whether alternative equivalent items would be acceptable. Clear instructions help the team respond with accurate information and prevent delays caused by missing quantities or unclear substitution rules.

Configuring the MICHELL Instruments S8000 HT for your process

The MICHELL Instruments S8000 HT is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.

  • Measuring range and the gas or sample the MICHELL Instruments S8000 HT will analyse.
  • Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
  • Supply voltage and the mounting style required on site.
  • Hazardous area classification of the installation location, if any.
  • Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.

Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.

Documents and quotation

The datasheet for the S8000 HT is attached on this page. To check availability, send an RFQ to Seven Star LLC with the part number S8000 HT, the quantity and your destination in Oman or the GCC.

Other Models in the Chilled Mirror Range

Seven Star LLC supplies models from the Chilled Mirror range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MICHELL Instruments S4000 TRS Precision Dew-Point HygrometerHumidity & Dew Point InstrumentsView details
MICHELL Instruments S8000 HT Chilled Mirror Hygrometer, 95 C dpHumidity & Dew Point InstrumentsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet MICHELL Instruments S8000 HT Chilled Mirror Hygrometer, 95 C dp Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the MICHELL Instruments S8000 HT Chilled Mirror

Answers from our engineering team on installation, compatibility and integration.

01What range does the S8000 HT cover?
The S8000 HT measures frost or dew point from -30 to +95 C with accuracy of plus or minus 0.1 C and stability of plus or minus 0.05 C.
02What is Frost Assurance on the S8000 HT?
FAST checks whether supercooled water could exist and, if so, drives the mirror to minus 30 C so ice is present, removing doubt about dew versus frost.
03What communications does the S8000 HT offer?
It offers Modbus RTU over USB, Modbus TCP/IP over Ethernet or RS485, two configurable 0-20 or 4-20 mA outputs and process and alarm relays.
04How is data logged on the S8000 HT?
Data logs to an SD card (8 GB supplied, up to 32 GB), allowing up to 24 million logs or 560 days at 2 second intervals.
05What sample flow does the S8000 HT need?
The recommended sample flow is 750 mL/min within 250 to 1000 mL/min, at a maximum sample gas pressure of 0.5 barg.