Brand:

IMI STI SC/VH Hydraulic Linear Valve Actuator

Description

IMI STI SC/VH hydraulic linear actuator for choke, gate and globe valves

The IMI STI SC/VH is a hydraulic linear piston actuator made to drive on-off and control valves in demanding power and oil and gas duty. The maker lists choke, gate, globe and wedge valves as typical targets. It is built from carbon steel with no cast iron, grey iron, ductile iron or aluminium parts, and the cylinder is electroless nickel plated to cut friction and prevent corrosion. Seven Star LLC supplies SC/VH actuators in Oman and the GCC as an independent supplier in Muscat.

Because the working medium is hydraulic oil at pressure up to 350 barg, the SC/VH delivers high thrust from a compact cylinder, and the design is described as maintenance-free for its operating life, even in harsh environments.

How to read SC/VH

  • SC is the STI linear (piston) actuator family; the same family includes pneumatic types such as SC and SC/V.
  • VH indicates the hydraulic version for valves with stem thrust requirements.
  • Double or single acting: double acting, or spring return where the spring gives the fail-safe action.
  • Action inversion is possible without inverting tubing only on the ND 1/4 in version.

The datasheet does not give a coded ordering matrix, so size, stroke, spring and bracket are defined per order from the valve data.

SC/VH technical specifications

Parameter Specification
Manufacturer / part number IMI STI / SC/VH Hydraulic Linear Actuator
Operating pressure Up to 350 barg
Standard operating temperature -30 to +100 °C; lower or higher temperature on request
Standard supply medium Hydraulic oil; fire-resistant fluid version on request
Sizes Several sizes from 30 mm to 300 mm cylinder, or larger if required
Stroke Several stroke options available
Action Double acting or single acting with spring return
Material Carbon steel, with no cast or grey or ductile iron or aluminium parts; full stainless steel design available
Cylinder finish Electroless nickel plated to minimise friction and prevent corrosion
Manual override Integral or declutchable hand-wheel, or hydraulic hand pump, on request
Mounting Customised valve bracket, open or close design, on request; quick valve adaptation available
Approvals listed PED 2014/68/EU, ATEX 2014/34/EU, Machinery Directive 2006/42, IP66/67M to IEC/EN 60529

How the SC/VH is built and operates

The brochure breakdown shows an end flange with stopper protection, a piston with scraper and gasket, tie rods, a head flange, a bracket, a stem adaptor, the cylinder stem, a stop screw and, for spring-return versions, a spring in a spring container. Hydraulic pressure acts on the piston and moves the stem through the stroke.

For safety, the spring pack compression is independent of the removal of the cylinder cap and tie rods, so the spring can be handled safely during service. A double guide for the piston, a spring bushing and a heavy-duty nickel-plated cylinder keep the motion smooth, and the compact design makes the actuator insensitive to vibration and external loads.

SC/VH within a hydraulic valve control system

The actuator is normally combined with a hydraulic power unit (HPU) and a control panel or cabinet, mounted on the actuator or remotely to limit heat and vibration. IMI designs accessories and control systems for modulating, on-off and heavy duty service, so positioners, solenoid valves and limit switches can be added. Related STI products include the RTQH and RTCH hydraulic scotch yoke actuators for quarter-turn valves and the SmarTrak ST hydraulic positioning controller.

Selection checklist for SC/VH

  • Valve type, stem thrust and stroke required, including seating force.
  • Hydraulic supply pressure and fluid, including whether fire-resistant fluid is needed.
  • Fail-safe action: spring to open or spring to close, or double acting.
  • Ambient and fluid temperature compared with the -30 to +100 °C standard.
  • Bracket and stem adaptor dimensions of the valve.
  • Manual override type: handwheel or hand pump.
  • Materials: carbon or full stainless steel.

Installation and maintenance of the SC/VH

Use the multiple lifting lugs, placed to balance the centre of gravity, for handling. Fit the bracket and stem adaptor to the valve as defined at order, then connect hydraulic tubing and test at the specified pressure before commissioning. Keep tubing clean to protect the seals.

The maker designs the actuator for maintenance-free service in normal operation. Periodic checks of leakage, stem condition and the bracket fasteners, with partial stroking where possible, are good practice. Spring-return versions must be serviced according to the spring safety instructions.

Applications in Oman and the GCC

Hydraulic linear actuators are used on wellhead chokes, gate valves for gas and oil gathering lines, and on power station steam and bypass valves where large thrust is needed. High ambient temperatures, dust and salty air near the coast make the nickel plating and IP66/67M protection relevant. For offshore or high-integrity duties, the fluid, temperature and approvals must be specified at order.

Hydraulic versus pneumatic linear actuators for valve duty

A hydraulic actuator works at far higher pressure than an air-operated one, so for the same cylinder diameter the thrust is much greater and the cylinder can be smaller. Hydraulic fluid is also practically incompressible, which gives stiff positioning and good resistance to process forces on choke and control valves. The trade-off is the need for a hydraulic power unit, tubing and fluid cleanliness control, which the maker supports with control panels and cabinets.

Information to send with an SC/VH RFQ

  • Valve type, size, rating and required thrust.
  • Stroke, and open or close fail action.
  • Hydraulic pressure available and fluid type.
  • Temperature range and area classification.
  • Manual override and accessory needs.
  • Drawing or dimensions of the valve bonnet and stem.

Documents and quotation

A product brochure for the SC/VH is attached on this page. Send the valve and hydraulic data quoting SC/VH and we will confirm the configuration and lead time.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

IMI STI is an Italian manufacturer of pneumatic, hydraulic and direct-gas valve actuators, valve positioners and actuator accessories. It is based in Levate, near Bergamo, and is part of the IMI plc group (IMI Process Automation).

Seven Star LLC is an independent supplier in Muscat. We list IMI STI positioners, actuators and switches for valve automation in Oman and the GCC and source them by full model code.

IMI STI company profile

Established 1960, in Gorle (Bergamo), Italy
Manufacturing site Levate (Bergamo), Italy, since 2014. The plant is about 15 km from the original Gorle site.
Group IMI plc, Process Automation division. STI S.r.l. is the legal entity and IMI STI is the brand name.
Product families Quarter-turn Scotch yoke actuators, linear actuators, lift-and-turn actuators, stepper actuators, valve positioners, limit switches, pressure switches and pneumatic accessories
Typical duty Emergency shutdown and isolation valves, anti-surge valves, turbine bypass and steam valves, dampers and process control valves
Industries Oil and gas, power, petrochemicals, process industries, water and metals

Milestones

  • 1960: STI is founded in Gorle, Bergamo.
  • 2002: IMI plc acquires STI, according to the company's own literature.
  • 2014: Manufacturing moves to the new plant in Levate, about 15 km from Gorle.

IMI STI product series

Series Type Key published data
RTC Pneumatic Scotch yoke quarter-turn actuator Up to 12 bar supply, -30 to +100 °C ambient, 90° rotation; single-acting, double-acting or spring-return; air, nitrogen, sweet or sour gas; ISO 5211 mounting; SIL 3, ATEX, PED, IP66/67M
RTQ High-torque pneumatic Scotch yoke actuator For large ball, plug and butterfly valves in harsh environments; canted or symmetrical yoke
RTQD / RTQH Direct-gas and hydraulic Scotch yoke actuators RTQD: gas-over-oil, operating pressure up to 114 bar, -20 to +100 °C; RTQH: hydraulic version for sites with a hydraulic power supply
SC/V, SC Pneumatic linear actuators For globe and gate valves (SC/V) and for dampers (SC); SC/VLT is the lift-and-turn version
SHP Smart high-performance positioner HART 7, self-tuning, Cv up to 2.3, 2.5 to 10.5 bar supply, ATEX and IECEx, IP66 aluminium or stainless steel housing
SHP-SIS Safety positioner IEC 61508:2010 up to SIL 3, built-in partial stroke testing, -55 to +85 °C ambient
FasTrak FT, QuickTrak Smart digital positioners and valve control systems Digital positioning with valve diagnostics
SA/CL Analog positioner Analog positioner for control valve actuators
2130 Limit switch box Position feedback for rotary valve actuators

Scotch yoke actuators give their highest torque at the start and end of the stroke. That is where a ball, plug or butterfly valve needs the most break-out and seating torque, so a Scotch yoke can be smaller than a rack-and-pinion actuator for the same valve. A canted yoke moves the torque peak toward one end of the stroke, for valves whose highest demand is when they close. A symmetrical yoke gives the same curve in both directions.

Where IMI STI products are used

In the GCC, IMI STI actuators and positioners appear mostly on emergency shutdown (ESD) and blowdown valves, compressor anti-surge valves, steam turbine bypass valves and large dampers in oil and gas, refining, petrochemical and power plants. On shutdown valves the SHP-SIS positioner adds partial stroke testing, so the valve can be proven to move without taking the plant down.

Ordering and replacement: what we need

For an actuator, send the full model code from the nameplate, the valve type and size, required torque or thrust with safety factor, supply medium and pressure, fail position (fail-close, fail-open or fail-last), stroke time, mounting flange (ISO 5211) and stem adaptor, ambient temperature range and the hazardous-area certification required. For a positioner, send the model, actuator type, signal (4-20 mA, HART), whether partial stroke testing or a SIL rating is needed, and the cable entry thread. When a series has been superseded, we quote the successor that IMI names in its documentation and point out any differences in mounting or signal.

Facts checked against IMI Process Automation product pages and published company history, October 2026.

FAQ

Questions about the IMI STI SC/VH Hydraulic Linear Valve Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the SC/VH used for?
It operates linear-motion valves such as choke, gate, globe and wedge valves in oil and gas and power service using hydraulic oil.
02What is the maximum operating pressure?
The brochure states operating pressure up to 350 barg, with a standard operating temperature of -30 to +100 °C and other temperatures on request.
03Is it available with spring return?
Yes. It can be supplied double acting or single acting with spring return. The spring pack can be handled independently of the cylinder cap and tie rods for safety.
04What sizes are offered?
Several cylinder sizes from 30 mm to 300 mm are listed, with larger sizes on request and a range of stroke options.
05Can it be used in a hazardous area?
The brochure lists ATEX 2014/34/EU and PED 2014/68/EU among its approvals, but the exact classification for your project must be confirmed at order.