HIMA ELOP II Pro V5.1 Engineering Software with Hardlock Key
Description
Overview
The HIMA ELOP II Pro V5.1 Engineering Software is the programming and configuration environment for HIMA safety systems, supplied with a portable hardware licence and a USB Hardlock key. The software version is ELOP II V5.1, the hardware licensing is portable, and it is supported on Windows XP and Windows 7. The USB dongle supports all configuration, programming and diagnostic tools, and the software is compliant with the IEC 61131-3 safety standard. For engineers maintaining HIMA safety controllers, HIMA ELOP II Pro V5.1 with its Hardlock key is the licence package needed to keep programming and diagnostics available.
Engineering Design
HIMA ELOP II Pro is the engineering software suite of HIMA for safety-related automation. It is used to create, configure, program and diagnose safety logic in accordance with IEC 61131-3, the international standard for programmable controllers. The licence is portable, which means it is tied to the USB Hardlock key rather than to a single PC, allowing the engineering tools to be used on different workstations. The key unlocks all configuration, programming and diagnostic tools, so a maintenance team with one licensed key can service the safety system from any authorised Windows XP or Windows 7 workstation.
Compatibility & Integration
HIMA ELOP II Pro V5.1 is supplied as a portable licence, which is a practical arrangement for plants where engineering is shared between the control room, the maintenance workshop and external service engineers. The licence runs on Windows XP and Windows 7 workstations, and the USB Hardlock key carries the licence, so the same key can be moved between authorised PCs without a licence transfer procedure.
Because the USB dongle supports all configuration, programming and diagnostic tools, a single licensed key covers the full engineering workflow of the HIMA safety system, from initial configuration to routine diagnostics during plant operation. For safety-instrumented systems, keeping the engineering environment available is as important as keeping the hardware spares in stock, which is why plants standardise on a licensed HIMA ELOP II Pro package.
Key Features
- ELOP II Pro software version V5.1
- Portable hardware licensing (USB Hardlock key)
- Runs on Windows XP and Windows 7
- USB dongle supports all configuration, programming and diagnostic tools
- IEC 61131-3 compliant engineering environment
- Complete licence package for HIMA safety system maintenance
Industrial Applications
- Programming and configuration of HIMA safety systems
- Safety logic changes and diagnostics in process plants
- Oil, gas, petrochemical and power facilities across Oman and the GCC
- Spare licence packages for installed HIMA safety systems
Technical Specifications
| Parameter | Specification |
|---|---|
| Product | HIMA ELOP II Pro Engineering Software |
| Software version | ELOP II V5.1 |
| Hardware licensing | Portable |
| Licence key | USB Hardlock key (dongle) |
| Supported OS | Windows XP, Windows 7 |
| Standard | IEC 61131-3 compliant |
| Tools | All configuration, programming and diagnostic tools |
Why Seven Star LLC
Seven Star LLC supplies automation software licence packages and spares to industrial customers across Oman and the wider GCC region. Every ELOP II Pro package we supply is checked against the version and licence details before dispatch, and our team confirms the licence configuration matches your maintenance environment before you order.
Ordering Information
To order the HIMA ELOP II Pro V5.1 from Seven Star LLC, quote the software version and the licence configuration you require. Our team confirms the package matches your HIMA system requirements and arranges delivery to your site in Oman or anywhere in the GCC.
FAQ
What is HIMA ELOP II Pro V5.1?
It is the engineering software environment for HIMA safety systems, version V5.1, supplied with portable hardware licensing and a USB Hardlock key.
How is the licence protected?
The licence is portable and protected by a USB Hardlock key (dongle), which supports all configuration, programming and diagnostic tools.
Which operating systems are supported?
The software is supported on Windows XP and Windows 7.
Is ELOP II Pro compliant with safety standards?
Yes. The software is IEC 61131-3 compliant.
How can I order ELOP II Pro from Seven Star LLC?
Send your request through our inquiry page with the software version and licence details. Our team confirms the package matches your HIMA system requirements before delivery.
Confirming the Right ELOP II Licence
ELOP II Pro is the engineering tool for the HIMA H41q and H51q safety controller families. It is easy to confuse with other HIMA engineering packages, so check a few points before you order a replacement or an additional licence:
- Controller family – confirm the installed system is an H41q/H51q-based PES. Other HIMA platforms use different engineering tools and cannot be programmed with ELOP II Pro.
- Software version – open the existing project and note the ELOP II version it was last saved with. Staying on the same version (V5.1 here) avoids project conversion and a full re-verification of the safety program.
- Licence form – this package is a portable licence carried on a USB Hardlock key. If your site currently uses a different key type, tell us so the replacement matches your workstation arrangement.
- Key label and serial – a photo of the existing dongle label helps us match the licence scope when you are replacing a lost or damaged key.
Setting Up the Engineering Workstation
Because ELOP II V5.1 is supported on Windows XP and Windows 7, most plants keep a dedicated engineering laptop or a virtual machine for it rather than loading it on a general office PC. A few practical rules keep the environment dependable:
- Keep the workstation off the corporate network and use it only for safety system engineering, in line with your site cybersecurity policy.
- Install the Hardlock driver before plugging in the key, and test that all configuration, programming and diagnostic functions open before the unit goes back into the cabinet or cupboard.
- Store a verified archive of every project version, together with the date and the change reference, on protected media.
- Log who holds the dongle. A portable licence is convenient, but a key that leaves site with a contractor can stop all online diagnostics.
Working Safely on a Running Safety System
Any change to safety logic should follow your management-of-change procedure. Before editing, compare the project on the workstation with the program loaded in the controller, so you are not working from an out-of-date copy. After the change, document the modified logic, repeat the relevant proof tests and archive the new project. Online diagnostics are useful for fault finding, but forcing signals on a live SIS needs the same authorisation and bypass control as any other safety override.
Use in Oman and GCC Plants
Many H41q and H51q systems in Omani and GCC oil and gas, gas processing and power facilities have run for well over a decade, often as ESD, fire and gas or burner management systems. The hardware is still in service, but the original engineering laptops have aged, and a lost or failed dongle can leave a site without the means to diagnose a trip or make an approved change. Holding a spare licensed key, or a second key for shutdown campaigns, is a simple way to reduce that risk.
Sourcing from Seven Star LLC
Send us the controller type, the ELOP II version in your current project and a photo of the existing key label. We check the package against those details and confirm the lead time and delivery to your site in Oman or elsewhere in the GCC before you place the order.
Related Products
- Schneider Electric EcoStruxure Building Operation Software
- 16413-1-1 / 16413-1-5 – Siemens APACS MBI/NMI PCI Card
- Schneider Electric Wiser Smart Building Energy System
- Siemens 6ES78105CC140YA5 SIMATIC STEP 7 Professional V17 Combo Engineering Software
- MTL PCS45 Configuration Software and PCL45USB Configurator
- Schneider Electric EcoStruxure Machine Advisor Software
Reviews (0)
How would you rate this product? Cancel reply
About brand
Emergency shutdown, burner management and fire and gas logic are the jobs HIMA controllers are built for. The company goes back to 1908 and is based in Brühl, Germany, and its whole catalog is safety-related automation. Seven Star LLC lists HIMA safety PLC systems and the modules that keep older HIQuad systems running, and sources them by part number for plants in Oman.
HIMA safety systems and modules listed
The listing covers three generations of HIMA hardware:
- HIQuad H41q and H51q: central modules such as F8650X, coprocessor F8621A, power supply and monitoring modules F7130A and F7131, coupling module F7553, current distribution F7105A, the H7506 bus terminal for HIBUS-2 and cabinet parts such as the K9202 fan drawer
- HIQuad X: the current modular system that continues the HIQuad line
- HIMax: the X-CPU 01 processor module for SIL 3 applications
Engineering software is part of the picture. ELOP II is the programming tool for H41q and H51q systems, while HIMax and HIQuad X are engineered with SILworX.
Where HIMA safety PLC systems are used
HIMA safety instrumented systems run ESD, process shutdown, burner management, turbomachinery protection and pipeline safety functions in gas plants, refineries, petrochemical complexes, terminals and power stations across the GCC. Many of these plants still operate H41q or H51q racks, so demand for single replacement modules is steady.
Ordering HIMA modules: what we need
HIMA modules are identified by the type printed on the front, for example F8650X, plus a nine-digit part number and a hardware revision on the side label. Send all three, with a photo if possible. Tell us the system type (H41q, H51q, HIQuad X, HIMax or HIMatrix) and, for central modules, the operating system version in use, because the replacement must be compatible with the running configuration. For software such as ELOP II, state the version and license type. We check the data against HIMA documentation and, when a module has been discontinued, propose the successor the manufacturer specifies.
Browse HIMA products by category: PLC & I/O Cards, Automation Software.
Related products
Frequently Asked Questions
It is the engineering software environment for HIMA safety systems, version V5.1, supplied with portable hardware licensing and a USB Hardlock key.
The licence is portable and protected by a USB Hardlock key (dongle), which supports all configuration, programming and diagnostic tools.
The software is supported on Windows XP and Windows 7.
Yes. The software is IEC 61131-3 compliant.
Send your request through our inquiry page with the software version and licence details. Our team confirms the package matches your HIMA system requirements before delivery.

Reviews
There are no reviews yet.