Brand: Fluke
Fluke 393 FC CAT III 1500 V True-rms Clamp Meter
Description
393 FC CAT III 1500 V clamp meter for solar and dc systems
The Fluke 393 FC is a true-rms clamp meter rated CAT III 1500 V, designed for technicians who work on dc systems such as solar arrays, wind power, electric railways and large battery banks. It measures up to 1500 V dc, 1000 V ac and 999.9 A dc or ac through a thin 34 mm jaw, and the included iFlex flexible probe extends ac measurement to 2500 A. Seven Star LLC supplies the 393 FC in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The full ordering name is “Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex”. The decoded elements follow.
| Element | Meaning | Detail |
|---|---|---|
| 393 | Model number | Dc-capable high-voltage clamp |
| FC | Fluke Connect compatible | Bluetooth to phone for logging and reports |
| CAT III 1500 V | Measurement category | Rated for 1500 V dc installations |
| with iFlex | Package content | 18 inch flexible current probe included |
393 FC technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 393 FC |
| ac current via jaw | 999.9 A, 0.1 A, 2 % + 5 digits (10 Hz to 100 Hz) |
| ac current via iFlex | Up to 2500 A, 3 % + 5 digits (10 Hz to 500 Hz) |
| dc current | 999.9 A, 0.1 A, 2 % + 5 digits (using the ZERO function) |
| ac voltage | Up to 1000 V, 1 % + 5 digits (20 Hz to 500 Hz) |
| dc voltage | Up to 1500 V, 1 % + 5 digits |
| dc power | 600.0 kVA (600 V range) and 1500 kVA (1500 V range), 2 % + 2 or 20 kVA |
| Resistance / capacitance | Up to 60 kΩ / up to 1000 µF, 1 % + 5 digits |
| Frequency | 5.0 Hz to 500.0 Hz |
| Safety | IEC 61010-2-032 and -033: CAT III 1500 V / CAT IV 600 V |
| Jaw opening / probe | 34 mm / iFlex diameter 7.5 mm, cable 1.8 m |
| Size / weight | 281 x 84 x 49 mm / 520 g with batteries |
| Batteries | Two AA alkaline |
| Operating / storage temperature | -10 °C to 50 °C / -40 °C to 60 °C |
| Wireless | 2400 MHz to 2483.5 MHz, output below 100 mW |
| Supplied with | CAT III 1500 V test leads, iFlex probe, TPAK strap, case, three-year warranty |
How the 393 FC measures dc power and polarity
On a dc string, power is the product of voltage and current. The 393 FC measures both and shows dc power in kVA on the 600 V and 1500 V ranges, so a technician can check a string without a calculator. Audio polarity indication warns when leads or conductors are connected the wrong way round, which helps prevent miswires on combiner boxes. Visual continuity lights the display green in dark or noisy spaces where a beeper is hard to hear.
The thin jaw is made for crowded boxes. The iFlex probe extends ac measurement to 2500 A and handles awkward conductors; it is sensitive to position, with errors of up to 0.5 %, 1.0 % and 2.0 % at increasing distances from the optimum position.
Where the 393 FC fits in the clamp range
Other clamps in this range stop at 1000 V. The 376 FC and 381 reach 999.9 A and 1000 V, while the 393 FC is the one for 1500 V dc. The 355 and 353 go up to 2000 A through a large jaw but are not rated for 1500 V. Choose the 393 FC when the system voltage exceeds 1000 V dc.
The datasheet also lists amps frequency and voltage frequency from 5.0 Hz to 500.0 Hz at 0.5 % + 5 digits, a 500 mV dc range, and an in-rush trigger level of 5 A. These are useful on inverter outputs and on ac sides of solar plants, where a frequency check confirms that the inverter is locked to the grid. Dual display with backlight and automatic power off after 20 minutes complete the practical features.
Selecting the 393 FC
- Confirm that the system voltage is up to 1500 V dc and the category requirement is CAT III.
- Check that the conductor will fit the 34 mm jaw or the iFlex probe.
- Decide whether Bluetooth logging and the manufacturer service are available to you.
- Verify the IP54 rating suits the environment.
- Plan spare leads rated CAT III 1500 V; do not substitute lower-rated leads.
Use and maintenance of the 393 FC
Use only the supplied CAT III 1500 V leads with safety caps on high-voltage dc circuits. Zero the dc current range before measuring, keep conductors centred and inspect the probe for damage. Accuracy is specified for one year after calibration at 18 °C to 28 °C. The IP54 rating helps outdoors but does not allow submersion. A premium carrying case is included.
Typical applications of the 393 FC in Oman and the GCC
Solar generation is growing in Oman and the GCC, and plant sizes mean 1000 V and 1500 V dc strings are widely used. The 393 FC suits string current and voltage checks, combiner-box inspections, battery bank testing and commissioning. Ambient temperatures in desert installations are high, so respect the 50 °C operating limit and record readings in the shade where possible.
Information to send with an RFQ for the 393 FC
- Part number 393 FC
- Quantity
- System voltage and current
- Delivery location and time frame
- Calibration certificate requirement
Storage, handling and spares for the Fluke 393 FC
Store the Fluke 393 FC in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 393 FC, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A datasheet for the 393 FC is attached on this page.
Send us the part number 393 FC and the quantity and we will confirm availability and a quotation.
Datasheets & Documents
- Datasheet Fluke 393 FC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 393 FC CAT III 1500 V True-rms Clamp Meter
Answers from our engineering team on installation, compatibility and integration.
01What voltage can the Fluke 393 FC measure?
The 393 FC measures up to 1500 V dc and 1000 V ac. It is rated CAT III 1500 V, which suits solar arrays, battery banks and other high-voltage dc systems.
02Does the Fluke 393 FC include an iFlex probe?
Yes. An 18 inch iFlex flexible current probe is included. It extends ac current measurement to 2500 A and reaches cables in tight spaces. The probe diameter is 7.5 mm.
03Can the Fluke 393 FC measure dc power?
Yes. It shows dc power in kVA, up to 600.0 kVA on the 600 V range and 1500 kVA on the 1500 V range, with 2 % of reading plus a fixed number of kVA.
04What IP rating does the Fluke 393 FC have?
The product description states IP54, intended for outdoor work in dusty or damp conditions such as solar arrays and wind power systems.
05What is included with the Fluke 393 FC?
The package lists the clamp meter, CAT III 1500 V test leads with right-angle plugs and safety caps, the iFlex probe, a TPAK magnetic strap, a premium case and a three-year warranty.


















Reviews