Brand: EUCHNER
EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943 Guard Locking Switch
Description
Overview
Teach-in capability is the defining trait of the EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943. This CET-AR safety switch with guard locking combines RFID transponder coding in Unicode mode with a dedicated teach-in input called J, so a new actuator can be taught in by applying 24 V DC to that input and then left unconnected during normal operation. The unit carries order number 110943 and the C number C2312, which the EUCHNER page describes as an extended escape release.
Guard locking follows the closed-circuit current principle. A spring holds the bolt in the locked position and the solenoid unlocks it, so a power failure leaves the guard locked. The switch reports its lock state on the monitoring output OUT, and it offers two redundant semiconductor safety outputs for the machine controller.
Seven Star LLC is an independent supplier serving Oman and the GCC. If your drawing shows CET1 with C2312, quote the complete code to us so that we match the exact configuration.
Specification table for EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943
| Parameter | Value |
|---|---|
| Series | CET-AR with guard locking |
| Order number | 110943 |
| C number | C2312, extended escape release |
| Coding | Unicode with teach-in input J |
| Teach-in input J | HIGH 15 to 27.6 V DC, LOW 0 to 1 V DC |
| Locking principle | Closed-circuit current |
| Escape release | 105 mm long |
| Locking force Fmax / Fzh | 6500 N / 5000 N |
| Safety | Category 4, PL e, SIL 3 |
| PFH | 3.1 x 10 to the power of minus 9 per hour |
| Mission time | 20 years |
| Supply UB / UCM | 24 V DC minus 15 % to plus 15 % / minus 15 % to plus 10 % |
| Current IB / ICM | 80 mA / 450 mA |
| Monitoring output OUT | p-switching, 0.8 UB to UB, 1 to 50 mA |
| Safety outputs OA, OB | Semiconductor, 1 to 200 mA, off-state current max 0.25 mA |
| Connector | 1 x M23, 19-pin, RC18 |
| Protection | IP65 / IP67 when screwed tight |
| Temperature | minus 20 to plus 55 degrees C operating, minus 25 to plus 70 degrees C storage |
| Housing | Die-cast aluminium, stainless steel ramp |
| Mechanical life | 2 x 10 to the power of 6 operations |
A day in commissioning
A typical start at a machine goes like this. The electrician mounts the EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943, fits the CET-A actuator on the door, connects the M23 cable and powers both UB and UCM. The ready delay of 10 s passes. Next, 24 V DC is applied to pin 13, the teach-in input J, and the actuator is presented to the ramp. Once the switch has stored the code, the voltage is removed from pin 13 and the input is left open for production.
Only the last taught-in actuator is recognised. This is the fundamental difference from multicode devices, where any compatible actuator will do. If a door is replaced or an actuator is damaged, an engineer repeats the teach-in with the new part and the old one is no longer accepted. That behaviour protects against casual bypassing with a spare actuator, which is the reason many safety departments specify Unicode on guards that operators open frequently.
How EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943 differs from other CET-AR variants
Against the 129491 version (C2467), this unit has the teach-in input on pin 13 whereas the C2467 version requires pin 13 to be connected to 0 V, and it has no lockout bar or door position output OUT D on pin 8, which is not connected here. The escape release is also described as extended in the C2312 code.
Against the multicode 110082 version, the spring-locked bolt, the Unicode coding and the 19-pin M23 connector are the contrast, because that unit uses open-circuit locking with two M12 plugs. All three share the ratings of Category 4, PL e and SIL 3, and the same locking force numbers of 6500 N and 5000 N.
Connector pins
- Pin 1: UCM, solenoid supply 24 V DC; pin 18: 0 V UCM.
- Pin 6: UB, electronics supply 24 V DC; pin 19: 0 V UB.
- Pins 2 and 3: enable inputs IA and IB.
- Pins 4 and 5: safety outputs OA and OB.
- Pin 7: reset input RST.
- Pin 10: OUT, guard lock monitoring output.
- Pin 12: functional earth, to be connected to 0 V.
- Pin 13: J, teach-in input.
- Pins 15 and 16: LED 1 red and LED 2 green, freely configurable at 24 V DC.
- Pins 8, 9, 11 and 17 are not connected; pin 14 must not be connected to 0 V.
Industries and duties
Gulf manufacturers that run presses, plastics machinery, textile-style winding equipment and large packaging lines use this class of switch to guarantee that a hazard has stopped before a guard opens. Workshops that support oil and gas assets, for instance valve repair benches with automated cells, use them in a similar way. Water and power utilities with maintenance workshops also encounter these interlocks when buying machine tools.
The 5000 N holding value allows use on substantial doors, and the extended escape release helps where the guarded area is large enough for a person to be inside by accident. The escape release frees the bolt from the danger zone without tools.
Selection notes
Order the actuator separately: the CET-A-BWK-50X (096327) is the standard type, and the CET-A-BWR-50X-170115 has improved properties for dirty environments. M23 cables with angled or straight connectors in 1.5 m and longer lengths are listed by the manufacturer. Check the cable exit direction against your cabinet layout.
Stay within the tolerance window of plus or minus 5 mm in X and Y and plus or minus 4 mm in Z, and do not exceed 20 m/min approach speed. The switching frequency is limited to 0.5 Hz, so the guard should not be cycled quickly.
Preventive checks
Inspect the ramp, actuator and mounting hardware, test the escape release, and read the STATE and DIA LEDs after maintenance. If the actuator is replaced, run the teach-in procedure again and verify the safety outputs. Keep the cable and connector free of oil and ensure the M23 coupling is fully tightened to retain the IP65 and IP67 protection.
Related items you may also need: EUCHNER CTM-LBI-BP-U-AZ-SA BiState Guard Locking Switch | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | EUCHNER ESM-TE301 Time-Delayed Safety Contact Expansion | All EUCHNER products.
Documents and quotation
The family data sheet accompanies this listing. For the EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943, please send an RFQ to Seven Star LLC stating the part number CET1-AR-CRA-AH-50F-SH-C2312-110943, the quantity and the delivery location, plus whether you need actuators and cables. We reply with availability and a quotation.
Other Models in the CET AR Range
Seven Star LLC supplies models from the CET AR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 Guard Locking Safety Switch | Safety Switches & Guard Locking | View details |
| EUCHNER CET2-AR-CRA-CH-50X-SG-110082 Multicode Guard Locking Switch | Safety Switches & Guard Locking | View details |
| EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943 Guard Locking Switch | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943 Guard Locking Switch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER CET1-AR-CRA-AH-50F-SH-C2312-110943 Guard
Answers from our engineering team on installation, compatibility and integration.
01What is the teach-in input J used for on this switch?
Applying 24 V DC to input J on pin 13 lets you teach in a new actuator. The input stays open during normal operation, and only the last taught-in actuator is accepted.
02Does the guard stay locked when power fails?
Yes. The switch uses the closed-circuit current principle, so a spring keeps the bolt locked until the solenoid is powered to unlock.
03What does the C2312 suffix indicate?
The EUCHNER product page lists C2312 as an extended escape release, which is a 105 mm long release for freeing a person from the danger zone.
04Which actuators fit this switch?
The CET-A-BWK-50X and the CET-A-BWR-50X-170115 are listed by EUCHNER as actuators for CET switches. They are not included and must be ordered separately.
05What are the safety ratings?
EUCHNER gives Category 4 and PL e for guard lock monitoring, SIL 3 under EN IEC 62061, with a PFH value of 3.1 x 10 to the power of minus 9 per hour.


















Reviews