Bürkert 559611 Type 8222 ELEMENT 4-Output Conductivity Meter
Description
Overview
Looking for a conductivity transmitter that gives a PLC two separate 4 to 20 mA signals, one for conductivity and one for temperature, plus two switching outputs? Bürkert 559611 is the article of the Type 8222 range built for exactly that: the four-output, three-wire ELEMENT standard meter with a 1.0 cell constant and a PVC union nut.
Where Bürkert 559611 sits in the 8222 range
Type 8222 is sold in two electronic versions. The ELEMENT neutrino version is a slim two-wire device without display. The ELEMENT standard version, to which this article belongs, adds a removable display and configuration module and offers either three or four outputs. Article 559611 is the four-output flavour: two transistors that can be set as PNP or NPN plus two current loops of 4 to 20 mA. It takes 12 to 36 V DC and uses two M12 connectors, a male and a female, both with five pins.
Its cell has graphite electrodes (cell constant 1.0 per centimetre) and a Pt1000 element inside a PVDF probe holder, joined to the process through a G 1½ union nut made of PVC. That PVC nut holds the fluid to 0 up to plus 50 degrees Celsius, which is the main practical difference from the PVDF-nut codes.
Measured values and accuracy
- Conductivity range 0.05 µS/cm to 10 mS/cm, deviation 3 percent of the reading, resolution 1 nS/cm
- Temperature 0.1 degree resolution in the standard variant, deviation 1 degree Celsius, minimum scale 10 degrees for the current output
- Current output uncertainty 1 percent of the range; minimum conductivity scale 2 percent of full scale
- Response of the current output 150 ms between 10 and 90 percent
In a three-wire hookup the supply returns and the two current loops share the electronics, so the analogue input card of the PLC should accept sourcing signals referenced to the supply. Maximum loop impedance is 1100 ohm at 36 V, 610 ohm at 24 V and 100 ohm at 12 V, which is lower than the two-wire article at the bottom of the supply range.
Bürkert 559611 data table
| Parameter | Value |
|---|---|
| Article | 559611 |
| Family | Type 8222 ELEMENT standard |
| Outputs | 2 transistors NPN/PNP and 2 x 4 to 20 mA (3 wires) |
| Supply | 12 to 36 V DC, current draw about 5 mA without load |
| Cell | C = 1.0 per cm, graphite electrode, Pt1000 |
| Union nut | PVC, G 1½ |
| Fluid temperature | 0 to +50 °C with this nut |
| Pressure | Maximum PN 16, reduced at higher temperature |
| Connectors | 5-pin M12 male and 5-pin M12 female |
| Covers and housing | PC cover, stainless steel 1.4404 and PPS housing |
| Ambient | -10 to +60 °C, humidity up to 85 % |
| Altitude | Up to 2000 m |
| Protection concept | Reverse polarity and overvoltage protected |
| Conformity | CE, PED article 4 paragraph 1 |
How 559611 differs from other 8222 variants
Compare the neighbours when you need to be sure. 559610 has the same cell and PVC nut but only one current loop and a 14 V minimum supply. 559613 has four outputs and the 1.0 cell like this article, but with a PVDF nut and therefore the wider minus 20 to plus 100 degree range. 559639 is the PVC and four-output code that adds UL Recognized marking. The 0.1 and 0.01 cell versions such as 559615 and 559619 use stainless steel electrodes for low conductivity water.
Use cases around the Gulf
Four outputs allow one device to feed a SCADA with both the conductivity trend and the process temperature, while the transistors close a conductivity-high alarm and a dosing permit. This pays off at small packaged RO skids, chilled-water loops, wash-down stations in food plants, and rinse monitoring in electroplating or galvanising lines found in Oman industrial zones. The PVC nut suits cool or ambient liquids and keeps the purchase proportionate where no hot media are involved.
Fitting and first start
Screw the union nut onto a Type S022 insertion adapter, or any pipe fitting with a G 1½ external thread. Plug in the display module, set the measuring range for each current loop, choose a compensation curve, and run the simulation function to verify scaling before commissioning. Mating M12 plugs are not included and must be ordered separately, as is the display module.
Care of the cell
Rinse the graphite electrode with water when deposits appear and recalibrate with a standard solution of known conductivity. Check seals and the cover whenever it has been opened. Keep cable glands and connectors tight so moisture cannot reach the electronics.
Planning the control loop
Think about what the receiving system will do with each signal before ordering. A common arrangement sends the conductivity loop to a controller that drives a blowdown or dilution valve, and uses the second loop for temperature compensation done upstream or simply for logging. The two transistor outputs can be mapped to a high alarm and a low alarm so that a hardwired interlock still works when the PLC is down for maintenance. Because every output is configured through the display module, one spare unit of this article can replace several different loops in a plant once the parameters are copied across, which shortens the spares list for maintenance planners in remote stations.
Cable length matters too. With the supply at the lower end of the range the loop resistance budget is small, so measure the actual resistance of the run to the input card and compare it with the impedance figures above. Shielded cable with the shield grounded at the cabinet side only is the usual recommendation in industrial surroundings that contain variable-speed drives and welding equipment.
What to prepare when quoting Bürkert 559611
- The quantity of 559611 and any spare units you want to hold
- Whether you need the removable display module, the M12 plugs, the Type S022 adapter or the USB interface set for the digital variants
- The pipe size and fitting material, so the temperature limit of the adapter can be checked against your fluid
- The conductivity band expected, to confirm that a 1.0 cell is appropriate
Seven Star LLC is an independent supplier serving Oman and the GCC.
Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert 020293 Type 0330 Brass 2/2-Way Solenoid Valve | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | All Bürkert products.
Documents and quotation
The data sheet for Type 8222 documents everything stated here for Bürkert 559611, including the pressure and temperature diagram, dimensions and ordering chart. Please include the part number 559611, the quantity, and any wish for accessories such as the display module or M12 connectors in your RFQ.
Other Models in the Burkert 8222 Range
Seven Star LLC supplies models from the Burkert 8222 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 559612 Type 8222 ELEMENT Conductivity Transmitter | Liquid Analysis Sensors | View details |
| Bürkert 559611 Type 8222 ELEMENT 4-Output Conductivity Meter | Liquid Analysis Sensors | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 559611 Type 8222 ELEMENT 4-Output Conductivity Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 559611 Type 8222 ELEMENT 4-Output
Answers from our engineering team on installation, compatibility and integration.
01How many outputs does Bürkert 559611 have?
Four: two transistor outputs configurable as NPN or PNP and two 4 to 20 mA current outputs, wired as a three-wire device.
02What is the supply range of 559611?
It operates from 12 to 36 V DC, filtered and regulated, from a limited-energy source. In humid or outdoor sites the maximum is 35 V DC.
03Why does 559611 have a lower fluid temperature limit than 559613?
Article 559611 has a PVC union nut limited to 0 to 50 degrees Celsius, whereas 559613 has a PVDF nut with minus 20 to plus 100 degrees Celsius.
04Are connectors supplied with Bürkert 559611?
No, the male and female M12 mating plugs and the display module must be ordered separately; the transmitter provides the fixed M12 sockets only.
05Which liquids suit the C = 1.0 cell on 559611?
The 1.0 graphite cell targets mid to high conductivity liquids such as industrial water or wastewater, up to the 10 mS/cm limit of the range.