Brand:

Autonics CT6M-1P2 6-Digit Counter Timer 72 x 72 mm 24 V

Description

Overview

Many plant control cabinets run on 24 volts: the PLC, the sensors, the solenoids and the indicators all share one DC rail. Putting a mains-powered counter into such a cabinet means an extra supply and extra wiring. The Autonics CT6M-1P2 avoids that problem. It is the large 72 by 72 mm member of the Autonics CT series with a six-digit display of 13 mm high red digits, a single preset stage and a supply that can be either 24 VAC or 24 to 48 VDC.

Seven Star LLC is an independent supplier serving Oman and the GCC. The CT6M-1P2 is requested for machines and skids where the counter must be easy to read from several metres away and where the control voltage is 24 V.

Autonics CT6M-1P2 specifications at a glance

Parameter Value
Display 6-digit LED, counting value red 6.6 x 13 mm, setting value green 5 x 9 mm
Case DIN 72 x 72 mm, about 85 mm deep
Panel cut-out 68 x 68 mm
Preset stages 1-stage
Counting range -99999 to 999999
Counter modes Count up, count down, count up and down
Counting speed 1 cps, 30 cps, 1 kcps, 5 kcps, 10 kcps selectable
Supply 24 VAC 50 and 60 Hz (10 VA), or 24 to 48 VDC (8 W), 90 to 110 percent
Relay output SPDT, 250 VAC 5 A, 30 VDC 5 A resistive
Solid state outputs NPN open collector, 30 VDC, 100 mA
External sensor supply 12 VDC, 100 mA
Extra inputs INHIBIT, RESET, BATCH RESET
Memory About 10 years, non-volatile
Dielectric strength 2,000 VAC for 1 minute
Noise immunity 500 V square wave, 1 microsecond
Ambient temperature -10 to 55 C
Front protection IP65

Why a low-voltage counter like the Autonics CT6M-1P2 is useful

A 24 V DC supply is the norm for machines built to European and Asian standards, and the same rail is used by sensors, PLC I/O and small valves. A counter that accepts 24 to 48 VDC can be wired straight to the rail without a transformer. If the cabinet has a 24 VAC control transformer, the same unit accepts that too.

At the same time, the power consumption is modest: up to 8 W for DC supply or 10 VA for AC supply. The external sensor supply of 12 VDC at 100 mA can power an inductive or photoelectric sensor directly from the counter, saving another power supply.

How CT6M-1P2 differs from other CT variants

The last digit of the code is the supply: 2 means 24 VAC or 24 to 48 VDC, whereas 4 means 100 to 240 VAC. The CT6M-2P4 in this size has two presets and mains supply. The CT6S and CT6Y use smaller cases with smaller digits. The M case is the one whose terminal drawings show a dedicated BATCH output and a BATCH reset input.

The 1P in this code means a single preset stage with one relay output, while 2P adds a second stage. Choose 1P for a simple batch limit; choose 2P for slow-down plus stop. The supply options also change the insulation data: DC and 24 VAC types are tested at 2,000 VAC between live parts and case, while mains types are tested at 3,000 VAC.

BATCH counting

In batch counting, the count value is compared with the preset, and each time it reaches the preset a batch counter is incremented and the main count restarts. A common example is cartons per pallet and pallets per shipment: the preset is the number of cartons in a layer, and the batch setting is the number of layers. The [BA] key shows the batch count, and the BA.O indicator lights when the batch output is on.

This function makes the CT6M suited to packing lines where the operator needs to see both quantities at once. The batch value can be reset separately from the main count.

Timer function

The same hardware works as a timer with 13 output modes. A time range from 0.001 s up to 99999.9 hours is available with six digits. Count-up and count-down timing are possible, and the INHIBIT input holds the timer. Typical uses are pump run-time limits, delayed starts and mould dwell times.

Wiring and mounting

Use the rear terminals: supply at the first pair, relay contacts on the next, and input and transistor output on the remaining group. Install the unit in a 68 mm square cut-out with the bracket. Keep signal lines away from power wiring and use shielded cable if the lines run near drives. For low voltage supplies, observe polarity when using DC. Use a separate switch or breaker for isolation.

Applications

Typical applications include bottling and packing machines, pumping stations with run-hour limits, and conveyor counting in logistics centres. In Oman, battery-backed 24 V DC panels in remote water and telecom sites make a DC counter practical, because the counter can run from the same battery-backed rail as the controller and the instruments. The large digits are a further benefit in dusty plant rooms and outdoor panels, where operators read the value through a window and may not be able to stand close to the door. After commissioning, use the key lock so that only trained staff can change the preset, and write the preset value on the panel label so that it can be checked quickly at shift change. Keep a note of the input logic and counting speed selected during setup, since a replacement counter has to be configured the same way before it is put into service.

Ordering

Send Autonics CT6M-1P2 with quantity on the RFQ. The 100 to 240 VAC version is CT6M-1P4, and communication models have a T at the end.

Related items you may also need: Autonics PR18-8DN M18 Inductive Proximity Sensor 8 mm | Autonics BEN5M-MFR Retroreflective Photoelectric Sensor 5 m | Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | All Autonics products.

Documents and quotation

The manufacturer publishes a product manual that covers Autonics CT6M-1P2, and the PDF is attached to this page for download so your engineers can check wiring, ratings and dimensions before ordering. Please send your RFQ with the part number and the quantity you need, plus the delivery site, and our team will reply with availability and lead time.

Other Models in the CT Range

Seven Star LLC supplies models from the CT range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Autonics CT6S-1P4 6-Digit Counter Timer 48×48 mmControllers & Data AcquisitionView details
Autonics CT6M-2P4 72×72 Six-Digit Counter/Timer 2-StagePhotoelectric SensorsView details
Autonics CT4S-1P4 48×48 4-Digit Counter/Timer 1-StagePhotoelectric SensorsView details
Autonics CT6S-2P2 48×48 6-Digit Counter/Timer 24 VPhotoelectric SensorsView details
Autonics CT6Y-1P4 Programmable 6-Digit Counter Timer 72 x 36Controllers & Data AcquisitionView details
Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm 2-StageControllers & Data AcquisitionView details
Autonics CT6M-1P2 6-Digit Counter Timer 72 x 72 mm 24 VControllers & Data AcquisitionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Autonics CT6M-1P2 6-Digit Counter Timer 72 x 72 mm 24 V Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics CT6M-1P2 6-Digit Counter Timer 72 x 72 mm

Answers from our engineering team on installation, compatibility and integration.

01What supply does the Autonics CT6M-1P2 need?
The 2 in the code means 24 VAC at 50 or 60 Hz or 24 to 48 VDC, with 90 to 110 percent tolerance.
02How big is the display?
It has six red digits of 6.6 x 13 mm for the count and green digits of 5 x 9 mm for the setting value, in a 72 x 72 mm case.
03Does it have a batch function?
Yes. The M case has a BATCH counter with its own key, indicators, output and reset input.
04How many presets does CT6M-1P2 have?
It has one preset stage. The 2P versions add a second stage.
05What panel cut-out is needed?
A square opening of 68 x 68 mm, with the unit about 85 mm deep behind the panel.