Brand:

Autonics TC4H-24R 48×96 PID Temperature Controller, 2 Alarms

Description

Overview

Tall instead of wide: the Autonics TC4H-24R is the vertical 48 x 96 mm controller of the TC family, with a single process display, two alarm relays, a relay plus SSR drive control output and a 100 to 240 V AC supply. Seven Star LLC is an independent supplier serving Oman and the GCC. Data on this page comes from the TC series instruction manual.

Vertical formats suit side-mounted panels, narrow control columns and machine frames where horizontal space is limited. The H size is also easy to read from a distance because the tall front gives the four digits room.

What TC4H-24R means

TC4 is the four-digit TC family. H gives the DIN format 48 mm wide by 96 mm high. The 2 in the third position means two alarm outputs, the 4 means 100 to 240 V AC at 50/60 Hz, and R means relay plus SSR drive output. Alternatives from the same table are N for an indicator without control output, and 2 for a 24 V AC or 24 to 48 V DC supply.

Data table for Autonics TC4H-24R

Item Data
Size 48 x 96 mm DIN, about 122 g, 194 g packed
Supply 100 to 240 V AC 50/60 Hz, 5 VA or less
Display Four-digit red LED with unit, setpoint, alarm and deviation indicators
Input K, J, L thermocouples; Cu50, DPt100 RTD
Control output Relay 250 V AC 3 A, 30 V DC 3 A, 1a
SSR drive 12 V DC plus or minus 2 V, 20 mA or less
Alarms Two relays, 250 V AC 1 A each
Control mode ON/OFF, P, PI, PD, PID
Proportional band 0.1 to 999.9
Integral and derivative time 0 to 9,999 s
Control cycle 0.5 to 120.0 s
Manual reset 0.0 to 100.0 percent
Relay life 200,000 electrical at full load
Insulation resistance 100 megohm or more at 500 V DC
Vibration 0.75 mm amplitude, 5 to 55 Hz
Operating temperature -10 to 50 C

Choosing the H size

The H housing has the same electronics as the other TC sizes, so the choice is purely mechanical. At about 122 g it is lighter than the 72 x 72 mm model, at about 133 g, and slightly heavier than the 48 x 48 mm version at about 94 g. The controller occupies 48 mm of width, so two of them fit in the width of one 96 mm unit, which is a neat arrangement for an upper and lower zone of an oven or a pair of heating circuits.

The keys are placed in the lower part of the front: a mode key and three setting keys for left, down and up.

Differences between TC4H-24R and neighbours

The TC4W-24R has the same two alarms but is a horizontal 96 x 48 mm unit. The TC4H-14R drops to one alarm. The TC4H-N units have no control output and work as indicators with alarms. The TCN4H-24R in the dual display series shows the setpoint on a second display. For all these, the specification table is nearly the same, but the weights, alarm counts and display differ.

Wiring the Autonics TC4H-24R

Use wire ferrules, fork terminals or round terminals within the manual’s width limit of 3.0 to 5.8 mm. For the Autonics TC4H-24R, observe polarity of the sensor, wire RTDs with three equal leads and use compensating cable for thermocouples. If the sensor cable and the power cable are close, use a line filter or varistor on the power and shielded wire for the sensor. A circuit breaker or switch within reach of the operator is mandatory according to the manual.

Mount by pushing the unit through the cut-out and fastening the bracket with a flat screwdriver as shown in the manual. After mounting, the unit is held by the bracket only, so avoid heavy cables hanging from the terminals.

Side-by-side zone layouts

Because the Autonics TC4H-24R is only 48 mm wide, a panel of 300 mm can carry six of them in a row, each with its own PV display and alarm indicators. This vertical row is common on plastic moulding machines, on multi-zone drying ovens and on pilot plants where the operator wants all setpoints at eye level in a column. The tall front also leaves space for a printed label strip above or below the unit, which helps the technician identify the zone without opening the manual.

When controllers are tightly packed, remember the heat they produce themselves and that of the relays and solid state relays in the same enclosure. The manual rates ambient temperature at -10 to 50 C, so leave a gap or fit ventilation if the panel contains heavy loads. SSR heat sinks, in particular, should be placed below or beside the controllers and not directly under them, since rising warm air would load the controllers above.

Before commissioning each zone, label the cable at both ends, write the sensor type and range on the panel drawing and verify the sensor type setting in the controller. A K thermocouple set to J gives a reading that looks plausible but is wrong by many degrees, a classic cause of overheating in a first trial run.

Alarm use and troubleshooting

Two alarm relays allow a layered response: for instance one alarm to warn the operator of deviation and the other to trip a contactor in case of over-temperature. If the controller displays OPEN, look for a broken or disconnected sensor. HHHH and LLLL indicate readings outside the input range. Remember that on such errors the control output may still be driven according to the control type, which can be full power in a heater.

Applications in Oman and the GCC

Typical uses are stacked zone controllers for ovens and dryers, heated tanks, bakery equipment, laboratory furnaces and compact dosing skids. Mount away from direct sun and ventilate the enclosure, since 50 C is the upper limit. Because it is not a safety limiter, use an independent device where over-temperature creates danger.

Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | Autonics PR18-8DN M18 Inductive Proximity Sensor 8 mm | Woodward 505 Digital Control for Steam Turbines | All Autonics products.

Documents and quotation

The TC series instruction manual is attached as a datasheet. Send an RFQ for TC4H-24R to Seven Star LLC with quantity and delivery location and we will confirm availability and lead time for Oman and the GCC.

Other Models in the TC4 Range

Seven Star LLC supplies models from the TC4 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Autonics TC4M-24R 72×72 PID Temperature Controller, 2 AlarmsControllers & Data AcquisitionView details
Autonics TC4Y-14R 72×36 PID Temperature Controller, 1 AlarmControllers & Data AcquisitionView details
Autonics TC4H-24R 48×96 PID Temperature Controller, 2 AlarmsControllers & Data AcquisitionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Autonics TC4H-24R 48x96 PID Temperature Controller, 2 Alarms Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics TC4H-24R 48×96 PID Temperature Controller,

Answers from our engineering team on installation, compatibility and integration.

01What format is Autonics TC4H-24R?
It is a vertical DIN 48 x 96 mm controller, a four-digit single display PID unit weighing about 122 g.
02How many alarms has TC4H-24R?
Two alarm relays, each rated 250 V AC 1 A, selected by the digit 2 in the code.
03What supply does the TC4H-24R need?
100 to 240 V AC at 50/60 Hz, shown by the 4 in the code, with a permissible range of 90 to 110 percent and consumption of 5 VA or less.
04Can TC4H-24R drive an SSR?
Yes, the R output includes a 12 V DC plus or minus 2 V SSR drive at up to 20 mA in addition to the 3 A relay.
05Does the TC4H-24R show setpoint on a second display?
No, it has one display and an SV indicator; the TCN series gives a separate setpoint display.