Brand:

Autonics MT4Y-AV-43 72×36 AC Voltage Panel Meter, Relay and 4-20 mA

Description

Overview

Reading mains voltage on the front of a panel, with a limit relay and a 4 to 20 mA signal for the PLC, is the job of the Autonics MT4Y-AV-43. It is a 4-digit multi panel meter in the 72 x 36 mm DIN format with AC voltage input, a 100 to 240 V AC supply, a relay output for low alarm and a DC 4 to 20 mA transmission output. Seven Star LLC is an independent supplier serving Oman and the GCC. The data below is taken from the MT4Y instruction manual and relates to this exact code.

A panel meter with its own transmission output replaces two instruments: the indicator on the door and the transmitter for the control system. In generator rooms, motor control centres and utility switchrooms, it is a common way to show line voltage locally and send the same value to a PLC or a monitoring system.

Order code MT4Y-AV-43 explained

Item Data
MT4Y Four-digit multi panel meter, DIN 72 x 36 mm
AV AC voltage input (DV is DC voltage, DA DC current, AA AC current)
4 100 to 240 V AC plus or minus 10 percent, 50/60 Hz supply
3 Preset output relay (LOW OUT) plus transmission output DC 4-20 mA

Autonics MT4Y-AV-43 specifications

Item Data
Display Red 7-segment LED, character height 14.2 mm
Display range -1999 to 9999
AC input allowable 10 to 110 percent of full scale of each range
AC voltage terminals 2 V and 1 V, 20 V and 10 V, 110 V and 50 V, 500 V and 250 V as marked on the terminal diagram
Accuracy at 23 plus or minus 5 C 0.1 percent of full scale reading plus or minus 2 digits
Accuracy over -10 to 50 C 0.5 percent of full scale reading plus or minus 3 digits
A/D conversion Sigma-delta
Sampling cycle 50 ms or 16.6 ms depending on input type
Relay 250 V AC 3 A, 30 V DC 3 A, 1a
Transmission output DC 4 to 20 mA, resolution 1/12,000, load 600 ohm or less
Transmission accuracy 0.3 percent of full scale
Transmission response 550 ms or less
Supply 100 to 240 V AC, 5 VA
Dielectric strength 3,000 V AC for one minute
Protection IP56 front
Ambient temperature -10 to 50 C
Weight About 134 g, about 213.5 g packed

Display messages

HHHH flashes when the input exceeds the maximum allowable 110 percent, and LLLL when it falls below the minimum allowable input (DC models only). D-HH and D-LL turn on when the displayed value exceeds the high or low limit of the scale setting or the display range of 9999 and -1999. F-HH appears if a frequency input exceeds the maximum of the measured range. OVER flashes twice when the zero range of plus or minus 99 is exceeded. The messages clear on their own once the input is again within range.

How MT4Y-AV-43 differs from other MT4Y codes

The MT4Y-DV-4 and DA-4 families measure DC voltage and current, and the AA types measure AC current. The last character selects the output: N is indicator only, 0 a relay, 1 NPN open collector, 2 PNP open collector, 3 relay plus 4-20 mA, 4 relay plus RS485 with Modbus RTU, 5 BCD dynamic and 6 low speed serial. The code AV-43 has the relay and 4-20 mA combination, so for a Modbus link choose a code ending in 4, which supports up to 31 units over 800 m.

Wiring the Autonics MT4Y-AV-43

The Autonics MT4Y-AV-43 has input terminals 1 to 7 and output terminals 8 to 13. Choose the input terminal that matches the expected voltage so that the reading is a good fraction of full scale; a 230 V line is read on the 500 V or 250 V terminals. The 4 to 20 mA output feeds a load of up to 600 ohms, such as a PLC analogue input with a shunt. Do not exceed the allowed input: the meter accepts up to 110 percent of full scale of each range.

Use shielded wire for the signal circuit and keep it away from power lines. Install a switch or breaker for the supply within the operator’s reach.

Using the 4 to 20 mA output

The transmission output of the Autonics MT4Y-AV-43 turns the displayed value into a standard analogue signal. The output resolution is 1/12,000 of span, the accuracy is 0.3 percent of full scale at 23 plus or minus 5 C, and the response time for a change from 15 to 95 percent is 550 ms or less based on a display cycle of 0.2 seconds. The loop resistance, including the receiving input and the wire, must not exceed 600 ohms. A typical PLC analogue input has a shunt of 250 ohms, which leaves plenty of margin.

When scaling at the PLC, remember that 4 mA represents the low end of the displayed scale and 20 mA the high end, and that the display scaling set in the meter decides which voltage corresponds to each. For example, a 250 V range scaled 0 to 250 V gives 4 mA at zero and 20 mA at 250 V. Always verify the scaling by applying a known voltage during commissioning, and record the result.

Because the relay and the 4 to 20 mA output share the same instrument, a failure of the meter takes both away at once. For critical alarm functions, such as undervoltage on a standby system, add a separate protection relay and use the meter as an indicator and trend signal.

Applications in Oman and the GCC

Typical places are generator control panels, motor control centres, water pumping stations, solar inverters rooms and building distribution boards, where phase voltage must be shown locally and reported to a SCADA system. The IP56 front keeps dust and spray from the panel face, while the rear terminals need a clean enclosure. Keep the ambient temperature below 50 C, which in a summer outdoor kiosk usually requires ventilation or shade.

Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | Autonics PR18-8DN M18 Inductive Proximity Sensor 8 mm | 16137-151 – Siemens APACS+/QUADLOG M-BUS Side A Cable (4 M) | All Autonics products.

Documents and quotation

The MT4Y instruction manual is attached as a datasheet. Send an RFQ for MT4Y-AV-43 to Seven Star LLC with quantity and delivery location and we will confirm availability and lead time for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Autonics MT4Y-AV-43 72x36 AC Voltage Panel Meter, Relay and 4-20 mA Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics MT4Y-AV-43 72×36 AC Voltage Panel Meter,

Answers from our engineering team on installation, compatibility and integration.

01What does Autonics MT4Y-AV-43 measure?
AC voltage, with several input ranges on separate terminals, displayed in four digits from -1999 to 9999.
02What output does the MT4Y-AV-43 provide?
A relay output of 250 V AC 3 A (1a) for the low alarm and a DC 4 to 20 mA transmission with 1/12,000 resolution and 600 ohm maximum load.
03What supply does the MT4Y-AV-43 need?
100 to 240 V AC at 50/60 Hz plus or minus 10 percent, with 5 VA consumption.
04What is the accuracy of the MT4Y-AV-43?
At 23 plus or minus 5 C it is 0.1 percent of full scale plus or minus 2 digits; over -10 to 50 C it is 0.5 percent plus or minus 3 digits.
05Does MT4Y-AV-43 have RS485?
No, the code 3 gives relay plus 4-20 mA; the RS485 Modbus RTU version has the code ending in 4.