Autonics CT4S-2P4 4-Digit Counter Timer 48 x 48 mm 2-Stage
Description
Overview
Not every application needs six digits. If the highest value you will ever show is a few thousand, a four-digit display gives you bigger, easier-to-read characters in the same panel space. The Autonics CT4S-2P4 is a four-digit programmable counter and timer in the 48 by 48 mm DIN case, with two preset stages and a supply of 100 to 240 VAC. Its red count digits measure 6.5 by 10 mm, which is about 45 percent wider than the 4.5 mm wide digits of the six-digit version in an identical case.
Seven Star LLC is an independent supplier serving Oman and the GCC. We offer it for operator panels where readability matters more than counting range, such as batch counters at filling lines, cut-to-length machines and press counters.
What the Autonics CT4S-2P4 specification contains
| Parameter | Value |
|---|---|
| Display | 4-digit LED, count red 6.5 x 10 mm, setting green 4.5 x 8 mm |
| Case | DIN 48 x 48 mm, about 90 mm deep |
| Panel cut-out | 45 mm square |
| Counting range | -999 to 9999 |
| Prescale | 0.001 to 999.9 |
| Time range | 0.001 s to 9999 hours |
| Presets | 2-stage |
| Counter modes | Count up, down, up and down |
| Counting speed | 1 cps, 30 cps, 1 kcps, 5 kcps, 10 kcps |
| Inputs | PNP voltage input (5 to 30 VDC high) or NPN no-voltage input |
| Relay output | 250 VAC 5 A resistive |
| Transistor output | NPN, 30 VDC 100 mA |
| One-shot time | 0.01 to 99.99 s |
| Supply | 100 to 240 VAC, 50 and 60 Hz, up to 12 VA |
| Sensor supply | 12 VDC 100 mA |
| Memory | About 10 years |
| Temperature | -10 to 55 C |
| Front protection | IP65 |
Autonics CT4S-2P4 compared with the six-digit counters
Fewer digits means a smaller range, but there are real benefits. With the same case, each of the four digits is larger, and the preset digits are 4.5 by 8 mm instead of 3.5 by 7 mm, so settings can be checked from further away. The counting range is -999 to 9999, enough for pallet layers, shift totals, tool-life counters and batch sizes.
The limits matter when pulses are scaled. The prescale range is 0.001 to 999.9 on the four-digit model, against 0.00001 to 99999.9 on six-digit units, so very fine scaling factors are not possible. For encoder lengths in millimetres over long rolls, choose a six-digit counter instead.
How CT4S-2P4 differs from other CT variants
The first digit after CT is the display digits, 4 here. The letter S is the 48 mm square case. 2P is two presets. The 4 at the end is 100 to 240 VAC. Replace the first digit with 6 and you get the CT6S-2P4 with six digits and the same supply; change 2P to 1P for a single preset, as in the CT4S-1P4; change the supply to 2 for 24 VAC or 24 to 48 VDC; add T for RS485 Modbus RTU.
The outputs are common to the family: relay contacts rated 250 VAC 5 A resistive for the 48 mm case, and an NPN open collector output of 30 VDC 100 mA.
Working with the two presets
Preset one and preset two are compared with the count value or elapsed time. Output modes determine whether each output stays on, switches off at reset, or sends a one-shot pulse. For counting, an example would be a warning at 90 and a stop at 100. For timing, a pre-alarm at 8 seconds and a trip at 10 seconds. The [PS1] and [PS2] indicators show which preset is being edited and the OUT1 and OUT2 indicators show output status.
Input signals
Count pulses go to INA. Using INB you can select direction or a second pulse input; INHIBIT stops counting or holds the timer. RESET sets the value to zero or to the start point. Voltage inputs are for PNP sensors, and shorted contacts or NPN sensors use the no-voltage setting. Use 1 cps or 30 cps if the signal comes from a mechanical contact, since higher speeds will count contact bounce.
Installation
Open a 45 mm square hole, push the unit in and lock the bracket. The depth behind the panel is about 90 mm, so check the clearance for wiring. Keep power and signal lines apart, use a switch or breaker close to the counter, and apply the supply only after wiring has been checked. After commissioning, activate the key lock so that the presets cannot be changed by accident. If the unit replaces an older counter, check the terminal layout against the old wiring before connecting, because terminal numbers differ between brands and even between series, and verify that the supply is within 90 to 110 percent of the rated 100 to 240 VAC range at the panel, not only at the transformer. A quick bench test with a hand-held switch on INA shows the display, the outputs and the reset behaviour before the counter goes into service.
Typical uses
In Gulf factories, four-digit counters are used on cartoning lines, labelling machines, weighing lines and punch presses. They also count valve operations and pump starts for maintenance planning, where the number rarely exceeds a few thousand between services. A cartoning line is a good example: the operator wants to see at a glance how many cartons are in the current bundle, the preset is typically a round number such as 24 or 48, and the second output can sound a horn a few cartons before the end so that the next pallet is ready. A tool-life counter on a punch press works in the same way, with the first preset warning of the approaching service and the second preset stopping the machine. Because the count survives a power cut, the number of strokes since the last tool change is never lost, and the reset key is pressed only after the new tool is fitted.
Ordering
Request Autonics CT4S-2P4 on your RFQ with quantity and mention whether you would prefer the six-digit CT6S-2P4 for wider range. Terminal covers can be added.
Related items you may also need: Autonics BEN5M-MFR Retroreflective Photoelectric Sensor 5 m | Autonics PR18-8DN M18 Inductive Proximity Sensor 8 mm | Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | All Autonics products.
Documents and quotation
The manufacturer publishes a product manual that covers Autonics CT4S-2P4, and the PDF is attached to this page for download so your engineers can check wiring, ratings and dimensions before ordering. Please send your RFQ with the part number and the quantity you need, plus the delivery site, and our team will reply with availability and lead time.
Other Models in the CT Range
Seven Star LLC supplies models from the CT range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Autonics CT6S-1P4 6-Digit Counter Timer 48×48 mm | Controllers & Data Acquisition | View details |
| Autonics CT6M-2P4 72×72 Six-Digit Counter/Timer 2-Stage | Photoelectric Sensors | View details |
| Autonics CT4S-1P4 48×48 4-Digit Counter/Timer 1-Stage | Photoelectric Sensors | View details |
| Autonics CT6S-2P2 48×48 6-Digit Counter/Timer 24 V | Photoelectric Sensors | View details |
| Autonics CT6Y-1P4 Programmable 6-Digit Counter Timer 72 x 36 | Controllers & Data Acquisition | View details |
| Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm 2-Stage | Controllers & Data Acquisition | View details |
| Autonics CT6M-1P2 6-Digit Counter Timer 72 x 72 mm 24 V | Controllers & Data Acquisition | View details |
| Autonics CT4S-2P4 4-Digit Counter Timer 48 x 48 mm 2-Stage | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Autonics CT4S-2P4 4-Digit Counter Timer 48 x 48 mm 2-Stage Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.
Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.
Autonics company profile
| Founded | 1977, South Korea |
|---|---|
| Current name | Autonics, since 1988 |
| Headquarters | Busan, South Korea |
| Factories | Busan and Yangsan |
| Product families | E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers |
Milestones
- 1977: The company is founded.
- 1988: Renamed Autonics Corporation.
- 2014: Opens its Busan headquarters.
Reading the Autonics E40S encoder code
E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.
Where Autonics encoders are used
Servo and spindle feedback, conveyor length measurement, packaging and printing machines.
Ordering Autonics encoders: what we need
Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.
Facts checked against Autonics corporate profiles, October 2026.
Browse Autonics products by category: Encoders.
FAQ
Questions about the Autonics CT4S-2P4 4-Digit Counter Timer 48 x 48 mm
Answers from our engineering team on installation, compatibility and integration.
01How many digits does the Autonics CT4S-2P4 display?
It has four digits, with red count digits of 6.5 x 10 mm and green setting digits of 4.5 x 8 mm.
02What is the counting range of CT4S-2P4?
The four-digit display covers -999 to 9999, depending on the decimal point setting.
03What supply voltage is used?
The 4 in the code means 100 to 240 VAC at 50 or 60 Hz.
04Does it have two outputs?
Yes, 2P means two preset stages, each with its own output indicator, plus relay and NPN transistor output types.
05Can I connect NPN and PNP sensors?
Yes. The input logic accepts PNP voltage signals of 5 to 30 VDC and NPN no-voltage contacts, with the 12 VDC 100 mA sensor supply available.