Brand:

EUCHNER TP3-4131A024M Guard Locking Safety Switch

Description

Overview

EUCHNER TP3-4131A024M is a guard locking safety switch in a reinforced thermoplastic housing, order number 084129. It belongs to the TP range of EUCHNER, the German maker of safety switches and locking devices, and it uses spring force to lock the guard. The lock is released only when the 24 V AC/DC solenoid receives power, the closed-circuit current principle, which keeps a door shut after a power failure. The TP3 version has two safe contacts for guard lock monitoring plus an extra NO contact, and a separate NO contact that reports the door position.

The actuator is not part of the delivery and must be chosen from the accessories list. A rotating head allows the actuator to enter from four directions in 90 degree steps. Seven Star LLC is an independent supplier serving Oman and the GCC.

EUCHNER TP3-4131A024M switching and locking behaviour

Switching element 4131 is a slow-action contact set. Guard locking is monitored by two positively driven contacts and one NO contact, while the door position is monitored by one NO contact. The manual explains that the TP3 and TP4 versions add at least one door monitoring contact to the guard lock monitoring that all TP versions have, and that TP5 and TP6 versions instead provide a door unlock request contact.

In practice the guard is locked by closing the door and removing voltage from the solenoid, and it is released by applying voltage. Because spring force does the locking, the guard stays locked when power is lost, which is why this principle is the one normally used for personnel protection. An auxiliary release on the front lets maintenance staff open the lock with a tool or key during a fault, and it must be protected against misuse by a seal or lacquer.

EUCHNER TP3-4131A024M technical data

Parameter Value
Series and order number TP, safety switch with guard locking, 084129
Switching element 4131, slow-action
Guard lock monitoring 2 positively driven contacts and 1 NO contact
Door monitoring 1 NO contact
Locking principle Closed-circuit current, power to unlock
Solenoid voltage 24 V AC/DC, minus 15 to plus 10 percent
Solenoid duty cycle 100 percent
Power consumption 8 W
Connection Three M20x1.5 cable entries
Conductor cross-section 0.34 to 1.5 mm2
Rated insulation voltage 250 V, impulse voltage 2.5 kV
Utilisation category DC-13 4 A at 24 V, AC-15 4 A at 230 V
Locking force Fmax 1300 N, Fzh 1000 N
Extraction force 20 N, retention force 10 N
Actuating force 10 N
Actuation frequency Up to 1200 per hour
Mechanical life 1 million cycles
Degree of protection IP67
Ambient temperature Minus 20 to plus 55 degrees Celsius
Housing material Reinforced thermoplastic, silver alloy gold-flashed contacts
B10D and mission time 3 million for guard lock monitoring, 20 years
Overtravel 2 mm horizontal and 1.5 mm vertical, 7 mm with the increased-overtravel actuator

The values are those shown on the product page for this order number and are valid for DC-13 at 100 mA and 24 V where stated.

How TP3-4131A024M differs from other TP switches

The TP range has six versions. TP1 and TP2 are the basic ones without door monitoring contacts, TP3 and TP4 add door monitoring, and TP5 and TP6 add the door unlock request. Odd numbers lock by spring force and release with power, even numbers lock with power and release by spring force. This order number is therefore the spring-locked, door-monitored version. By contrast, TP3-2131A024M shares the spring-locking principle but uses switching element 2131 with an NC door contact, and TP4-2131A024M locks with power on, the open-circuit current principle.

The switching element digits tell the contact makeup. Element 4131 here pairs the NO door contact with two positive-drive lock contacts. Other elements use NC door contacts or 1NO plus 2NC combinations. The 024 in the code is the 24 V solenoid, while codes with 110 or 230 use mains voltage, and codes ending in SR11 or other connectors have plugs in place of cable entries.

Applications

A spring-locked switch with a monitored door suits guards that stay closed until the machine has stopped: wrapping machines, mills, presses, test cells, packaging, mixers and conveyors. In Oman, such guards appear in food and date processing plants, water treatment skids and metal workshops. The plastic housing works well on washed or humid machinery where corrosion of metal housings is a worry.

Selection notes

Choose an actuator from the accessories: straight and bent stainless steel actuators, hinged actuators for doors hinged left or right or at top and bottom, and overtravel versions for doors with rubber end stops. For personnel protection with an interlock, apply the guidelines of EN ISO 14119 and pick escape release or emergency release options as needed. Add an LED set if the guard status must be visible from outside.

Installation and commissioning

Mount the housing on a rigid frame so that the actuator enters straight. To change the approach direction, remove the head screws, set the new direction, tighten them to 0.8 Nm and cover the unused slot with the slot cover supplied. Strip conductor ends by about 6 mm and use only the safe contacts in the safety circuit. Check each release function after installation, and run a function test of door and lock monitoring.

Maintenance

Inspect screws, actuator, cable entries and the sealing of the auxiliary release at regular intervals. Do not use a bent or damaged actuator. After any manual release, perform a function test as the manual advises.

Ordering notes

Quote requests should list the actuator type, any cable glands, the LED set or bolt accessories and the quantity.

Related items you may also need: EUCHNER TX1B-A024M Guard Locking Safety Switch | EUCHNER ZSM2100 Three-Position Enabling Switch | EUCHNER ESM-BT411 Safety Relay with Time-Delayed Contacts | All EUCHNER products.

Documents and quotation

The manufacturer operating instructions for the TP range, which cover the data of EUCHNER TP3-4131A024M, are attached as the datasheet. Send an RFQ with the part number EUCHNER TP3-4131A024M, the quantity and your destination in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.

Datasheets & Documents
  • PDF Datasheet EUCHNER TP3-4131A024M Guard Locking Safety Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER TP3-4131A024M Guard Locking Safety Switch

Answers from our engineering team on installation, compatibility and integration.

01Is an actuator included with EUCHNER TP3-4131A024M?
No. The product page states that the actuator is not included, so a straight, bent or hinged stainless steel actuator must be ordered separately.
02How does the guard lock of TP3-4131A024M work?
It is spring-locked and unlocked by solenoid power, the closed-circuit current principle, so the guard remains locked if the 24 V supply fails.
03What contacts does switching element 4131 provide?
Guard lock monitoring uses two positively driven contacts plus one NO contact, and door monitoring uses one separate NO contact.
04What locking force does TP3-4131A024M reach?
The maximum locking force Fmax is 1300 N and the holding force Fzh is 1000 N, with an actuator extraction force of 20 N.
05What protection degree and temperature range apply?
The housing is rated IP67 and the ambient temperature range is minus 20 to plus 55 degrees Celsius, with 1 million mechanical cycles.