Brand: Pizzato
Pizzato CS AT-01V024 Safety Module with Delayed Contacts
Description
Overview
The Pizzato CS AT-01V024 is a relay safety module that watches emergency stop circuits and guard-door limit switches, and that keeps two of its outputs alive for an adjustable time after the guard is opened. Pizzato groups it in the CS AT-0 range: safety circuits up to SIL 3 and PL e, with two instantaneous normally open safety contacts, one instantaneous normally closed signalling contact and two normally open contacts that release late. This code carries the 24 V ac/dc supply, screw terminals and delay range 1, which gives an adjustable stop time of 0.3 to 3 seconds in steps of 0.3 seconds. Seven Star LLC is an independent supplier serving Oman and the GCC.
Where the delayed contacts earn their place
Many machines do not stop the moment the power is cut. A saw blade, a pulley, a flywheel or a hydraulic press keeps moving for a while, and a guard that can be opened immediately would put a hand next to hazardous motion. The delayed outputs of this module are the answer: when the safety input opens, the instantaneous contacts drop at once and remove the drive command, while the delayed pair stays closed long enough for the drive to brake or for the inertia to run down. The delayed pair then opens and can feed a guard-locking solenoid, a brake release or a second contactor. With code 1 you can tune that waiting time from 0.3 to 3 seconds on the front panel, so one stocked module covers many machine types.
Data summary for Pizzato CS AT-01V024
| Parameter | Value for Pizzato CS AT-01V024 |
|---|---|
| Functions | Emergency stop and movable guard monitoring with delayed contacts |
| Safety integrity | Up to SIL 3 (EN 62061) and PL e (EN ISO 13849-1) |
| Category | Category 4 for instantaneous contacts, category 3 for delayed contacts |
| Output contacts | 2NO instantaneous safety, 1NC instantaneous auxiliary, 2NO delayed safety |
| Delay range (code 1) | 0.3 to 3 s, adjustable in 0.3 s steps |
| Supply (code 024) | 24 Vac/dc, 50 to 60 Hz, tolerance minus 10 to plus 15 percent |
| Power consumption | Below 10 VA on ac, below 5 W on dc |
| Input protection | PTC resistance, Ih 0.5 A, response over 100 ms, reset over 3 s |
| Maximum resistance per input | 50 ohm; current per input below 40 mA |
| Response time tA | Below 300 ms |
| Release time tR1 | Below 25 ms; tR without supply below 150 ms |
| Contacts | Forcibly guided, silver alloy, maximum 230/240 Vac or 300 Vdc |
| Utilisation categories | AC-15 230 V 3 A; DC-13 24 V 4 A |
| Thermal current Ith | 6 A per branch; external fuse 4 A |
| Housing | Polyamide PA 66, V0; IP40 housing, IP20 terminals |
| Ambient temperature | Minus 25 to plus 55 degrees Celsius |
| Endurance | Over 10 million mechanical and over 100,000 electrical cycles |
Reading the code Pizzato CS AT-01V024
The catalogue code structure splits the number into pieces. CS AT is the series, the first digit 0 is the generation, and the digit that follows picks the delay: 0 means a fixed time defined by an option such as TF0.5, TF1 or TF3, 1 means 0.3 to 3 seconds, 2 means 1 to 10 seconds, 3 means 3 to 30 seconds and 4 means 30 to 300 seconds. The letter V stands for screw terminals, while M and X are the connector versions with screw or spring terminals. The last three characters give the supply: 024 for 24 V ac/dc, 120 for 120 Vac and 230 for 230 Vac. Read in order, 01V024 therefore means delay range 1, screw terminals, 24 V.
How CS AT-01V024 differs from its siblings
Within the same family the electrical behaviour is the same and the differences are the stop time and the supply. A CS AT-02 code stretches the adjustable range to 1 to 10 seconds in 1 second steps, a CS AT-03 code to 3 to 30 seconds in 3 second steps, and a CS AT-04 code to 30 to 300 seconds in 30 second steps. Choosing range 1 gives the finest resolution, which suits machines that coast down in a couple of seconds. The 120 and 230 volt codes allow direct connection to an ac control supply, whereas this 024 version relies on a 24 V source and, according to the catalogue, a 24 V ac/dc unit used under the UL rating must be fed from a remote Class 2 or limited energy source.
Inputs and start behaviour
The module accepts one or two channels. They can be wired to electromechanical contacts such as an emergency stop button or a guard switch, to magnetic safety sensors, or to OSSD semiconductor outputs from safety light barriers or coded sensors. The start function is configurable: automatic, manual or monitored start. A manual or monitored start button is connected on S33 and S34, and the monitored mode refuses to restart if the button contact was already closed before the inputs became valid. Input channels of opposite potentials may be connected, which helps when two supplies are involved.
Typical use in Oman and the GCC
Plants in Oman often run rotating equipment with long run-down times: crushers in aggregate and cement plants, conveyor head drives at ports, packaging lines in food factories, and compressors with heavy flywheels. A module with delayed contacts lets the engineer open the guard of such a machine while the drive brakes, and the machine remains locked until the delayed pair has dropped. The same logic is used on presses and shears, where a guard-locking solenoid should be released only after the dangerous movement has ended. Because the housing is rated -25 to +55 degrees Celsius, the module belongs inside a ventilated control panel, not on a sunlit outdoor surface.
Wiring and commissioning notes
Terminals A1 and A2 carry the supply, S11 and S12 form the first input channel, S21 and S22 the second, 13 to 14 and 23 to 24 are the instantaneous safety outputs, 31 to 32 the signalling contact, and 47 to 48 and 57 to 58 the delayed safety outputs. Wire the safety function to the safety contacts only, and use the signalling contact for the PLC. Protect the outputs with the 4 A fuse stated in the data, check that the input resistance including cable stays below 50 ohm, and measure the real stop time of the machine, then set the front dial so the delayed pair opens only after the hazard has ended. Record the setting in the machine file and seal the dial where your procedure requires it.
Maintenance and testing
The module has no serviceable parts. At each proof test, operate the emergency stop and open each monitored guard, confirm that the instantaneous contacts open immediately, that the delayed contacts open after the set time, and that the machine cannot restart until the start condition is met. Replace the module if a contact welds or the indicators show a persistent fault, rather than bridging the problem. Keeping one spare Pizzato CS AT-01V024 on the shelf shortens an outage, because the dial settings are the only thing to copy across.
Selecting between a timed module and a plain one
If the machine stops within a fraction of a second, a module without delayed contacts is simpler. If the stopping time is known and repeatable, a fixed-time version may be better because nobody can tamper with it. Range 1 is the choice when the time is short but may be tuned at commissioning. When more than two delayed contacts are needed, add expansion modules from the same catalogue instead of loading the module contacts beyond their ratings.
Related items you may also need: Pizzato FR 1007 Position Switch, Adjustable Roller | Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | All Pizzato products.
Points to confirm for the Pizzato CS AT-01V024
- If the Pizzato CS AT-01V024 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Pizzato CS AT-01V024 request we confirm the exact code, new or surplus condition and lead time in writing.
- Dimensions, ratings and connection data for the Pizzato CS AT-01V024 are in the datasheet attached to this page.
- The Pizzato CS AT-01V024 belongs to our safety switches & guard locking range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Pizzato CS AT-01V024 on critical service often hold a spare unit in the store.
Documents and quotation
The manufacturer catalogue sheet for the CS AT-0 family is attached to this page and includes the technical data, code structure, pin assignment, function diagrams and input configurations. To receive a quotation, send an RFQ that quotes Pizzato CS AT-01V024, the quantity, the supply voltage of your panel and your delivery destination in Oman or the GCC. We will confirm availability and lead time and, if required, propose matching expansion modules and DIN rail accessories.
Datasheets & Documents
- Datasheet Pizzato CS AT-01V024 Safety Module with Delayed Contacts Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS AT-01V024 Safety Module with Delayed
Answers from our engineering team on installation, compatibility and integration.
01What delay range does the Pizzato CS AT-01V024 offer?
Delay code 1 gives an adjustable release time of 0.3 to 3 seconds in 0.3 second steps for the two delayed normally open contacts.
02Which outputs does the CS AT-01V024 provide?
It has two instantaneous normally open safety contacts, one instantaneous normally closed signalling contact and two delayed normally open safety contacts.
03What supply does the CS AT-01V024 need?
The 024 code is supplied with 24 V ac/dc at 50 to 60 Hz, tolerance minus 10 to plus 15 percent, drawing below 10 VA on ac or below 5 W on dc.
04What safety level can the CS AT-01V024 reach?
The catalogue states up to SIL 3 and PL e, with category 4 for the instantaneous contacts and category 3 for the delayed contacts.
05Which devices can be connected to the inputs of the CS AT-01V024?
One or two channels from electromechanical contacts, magnetic safety sensors or OSSD semiconductor outputs, with automatic, manual or monitored start.


















Reviews