Brand:

ebm-papst 3956 L AC Axial Panel Compact Fan 92 mm 230 V Quiet

Description

Overview

Some equipment needs air movement but cannot tolerate noise, bulk or much power. The ebm-papst 3956 L is built for that role. It is an AC axial panel compact fan from ebm-papst St. Georgen with a slim 25 mm depth, a 92 by 92 mm frame and a weight of only 0.280 kg. At 230 V and 50 Hz it turns at 1550 rpm, uses just 6 W, delivers 31 cubic metres per hour in free air and produces a sound pressure level of only 24 dB(A). Its permitted ambient range is wide: minus 40 to plus 80 degrees C. Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical data of ebm-papst 3956 L

Item ebm-papst datasheet value
Item and motor ebm-papst 3956 L, motor -0
Phase 1 phase
Voltage and frequency 230 VAC, 50 Hz
Speed 1550 rpm
Power consumption 6.0 W
Air flow 31 m3/h
Sound power level 3.8 B
Sound pressure level 24 dB(A)
Ambient temperature minus 40 to plus 80 degrees C
Weight 0.280 kg
Dimensions 92 x 92 x 25 mm
Impeller Mineral-reinforced PA plastic
Housing Die-cast aluminium
Airflow direction Exhaust over struts
L10 life at 40 degrees C / at maximum temperature 70000 h / 27500 h

A quiet, thin fan: what the numbers say

With 24 dB(A) the fan is almost inaudible in a room; for comparison, the 4650 N reaches 46 dB(A) and the 3606 reaches 42 dB(A). The low speed of 1550 rpm explains this, and it also explains the long calculated life of 70000 hours at 40 degrees C, about eight years of continuous running, the longest among the AC fans we list. The price is airflow: 31 m3/h is a third of what a 3606 delivers. The slim depth of 25 mm instead of the usual 38 mm helps in flat housings, panels and instruments where a thicker fan would not fit. The plastic impeller is made from mineral-reinforced polyamide, and the aluminium frame keeps the structure stiff.

How ebm-papst 3956 L differs from the 3606 and 8500 N

The 3606 is a 92 mm fan of the same footprint but 38 mm deep, running at 115 V, 3200 rpm and 11 W for 89 m3/h. The 8500 N is an 80 mm fan with 61 m3/h. Both are 115 V 60 Hz fans, while the ebm-papst 3956 L runs on 230 V 50 Hz, the local standard. If your priority is silence, mains compatibility and low power, the ebm-papst 3956 L is the better fit; if you need more airflow, choose a different fan from the range or fit two units.

Where it is used in Oman and the GCC

A fan with 31 m3/h suits small enclosures with modest heat loads, such as instrument housings, analyzers, flow computers, communication boxes, small power supplies, displays and point-of-sale equipment. The wide temperature range makes it usable in outdoor cabinets that experience hot summer sun and in cold rooms. It is also well suited to rooms where noise must be low, such as control rooms, laboratories, medical and office equipment.

Installation

Fix the fan with four screws in the corner holes, with the air leaving over the struts. Connect to a 230 V, 50 Hz supply; a 115 V supply is not suitable. Provide a finger guard on exposed sides. Because the airflow is small, keep the resistance low: avoid fine filters and narrow slots in front of the fan, and ensure that the exhaust path is open. For better results use the fan with a defined intake low in the enclosure and exhaust through the fan at the top.

Maintenance and life

The life figure of 70000 hours at 40 degrees C falls to 27500 hours at the maximum temperature of 80 degrees C, so a hot environment shortens life substantially. Plan replacement according to the actual operating temperature, listen for any change in sound, and clean the blades gently when dust collects. A spare unit on the shelf is cheap protection for critical electronics.

Is 31 m3/h enough?

Air carries about one third of a watt-hour per cubic metre per kelvin, so 31 m3/h removes roughly 10 W per kelvin of temperature rise in free air. For an enclosure with 10 W of losses that is allowed to rise by 3 kelvin, the fan is adequate, but for 30 W of losses a rise of ten kelvin would result, and real airflow through grilles will be lower. Use it where heat loads are small or where the aim is to stir air and avoid hot spots.

Using several small fans instead of one large one

When the heat load of an enclosure is larger than a single quiet fan can handle, there are two common strategies. The first is to raise the airflow with a larger or faster fan, which brings noise and power with it. The second is to spread the cooling over several small fans placed where hot spots occur, each moving a little air, so that the sum is enough and the noise of each unit stays low. Because the noise of fans adds logarithmically, two units of 24 dB(A) together produce about 27 dB(A), still far quieter than a single fan of 46 dB(A). Distributed cooling also provides redundancy, since the failure of one fan reduces the airflow by half and not entirely. Place intake openings low and on the opposite side from the fans so that air sweeps across the components, and keep cables and tall parts out of the airflow so they do not create dead zones. A thermostat can switch the fans on only when needed, which further lowers wear and noise.

Selection checklist

Before ordering, confirm the supply voltage and frequency, the cut-out and hole pattern of the 92 mm frame, the depth available, the direction of airflow and the connection style. Check that the temperature range covers the coldest and hottest conditions the equipment will see, and that the airflow suffices for the heat load with allowance for filters. If any of these is uncertain, send the equipment details with your RFQ so that the suitability can be reviewed before ordering.

Related items you may also need: ebm-papst R1G225-AF11-52 DC Fan | ebm-papst Industrial Cooling Fan | ebm-papst R1G175-AB41-02 DC Fan | All ebm-papst products.

Checklist before ordering the ebm-papst 3956 L

  • Before ordering the ebm-papst 3956 L, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the ebm-papst 3956 L code and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the ebm-papst 3956 L dimensions, ratings and connections.

Documents and quotation

The ebm-papst datasheet for the ebm-papst 3956 L with nominal data, dimensions, the airflow curve and the product drawing is attached. Send your RFQ with ebm-papst 3956 L, the quantity and your delivery location in Oman or the GCC.

Other Models in the Ac Axial Panel Range

Seven Star LLC supplies models from the Ac Axial Panel range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ebm-papst 3606 AC Axial Panel Compact Fan 92 mm 115 V 60 HzIndustrial Fans & BlowersView details
ebm-papst 8500 N AC Axial Panel Compact Fan 80 mm 115 V 60 HzIndustrial Fans & BlowersView details
ebm-papst 3956 L AC Axial Panel Compact Fan 92 mm 230 V QuietIndustrial Fans & BlowersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet ebm-papst 3956 L AC Axial Panel Compact Fan 92 mm 230 V Quiet Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ebm-papst is a German family-owned maker of fans and motors, headquartered in Mulfingen. It was founded in 1963 by Gerhard Sturm and Heinz Ziehl as Elektrobau Mulfingen (ebm) and took its current name after acquiring Papst in 1992. ebm-papst makes EC fans, blowers and motors for ventilation, cooling and air conditioning.

Seven Star LLC is an independent supplier in Muscat. We list ebm-papst fans for equipment cooling in Oman and the GCC.

ebm-papst company profile

Founded 1963, Mulfingen, Germany
Founders Gerhard Sturm and Heinz Ziehl
Headquarters Mulfingen, Germany
Ownership Family-owned
Product families RadiCal and R1G EC centrifugal fans, axial fans, compact DC fans, EC motors

Milestones

  • 1963: Elektrobau Mulfingen is founded.
  • 1992: ebm acquires Papst and becomes ebm-papst.

ebm-papst product series

Centrifugal fans include the R1G175-AB41-02 and R1G225-AF11-52 DC fans with backward curved impellers. Papst industrial cooling fans are used in cabinets and electronics.

Replacements should match the part number exactly, as size, voltage, airflow, speed signal and connector can differ between versions. EC fans can be speed controlled to save energy and reduce noise.

Where ebm-papst fans are used

Cooling of drives, UPS, telecom and control cabinets, HVAC units and electronic equipment.

ebm-papst products we list

Family Examples
Cooling R1G175-AB41-02 DC Fan, R1G225-AF11-52 DC Fan
Automation Accessories Papst Industrial Cooling Fan

Ordering ebm-papst fans: what we need

Send the full part number from the label, voltage and quantity.

Facts checked against ebm-papst's published company history, October 2026.

FAQ

Questions about the ebm-papst 3956 L AC Axial Panel Compact Fan 92 mm

Answers from our engineering team on installation, compatibility and integration.

01How quiet is the ebm-papst 3956 L?
The datasheet gives a sound pressure level of 24 dB(A) and a sound power level of 3.8 B, making it one of the quietest AC axial fans in the compact range.
02What supply does the ebm-papst 3956 L need?
It needs a single-phase 230 VAC, 50 Hz supply and draws 6.0 W at a speed of 1550 rpm.
03How big is the ebm-papst 3956 L?
The frame measures 92 x 92 x 25 mm, thinner than the 38 mm of the 3606, and the weight is 0.280 kg.
04What temperatures can the ebm-papst 3956 L tolerate?
The permitted ambient range is minus 40 to plus 80 degrees C, with L10 life of 70000 hours at 40 degrees C and 27500 hours at the maximum temperature.
05What airflow does the ebm-papst 3956 L deliver?
It delivers 31 cubic metres per hour in free air, with the air exhausting over the struts and a mineral-reinforced PA plastic impeller.