Brand:

Magnetrol Echotel 910 Ultrasonic Liquid Level Switch

Description

Overview

The Magnetrol Echotel 910 is a compact ultrasonic level switch for clean liquids that detects the presence or absence of liquid in a small gap at the tip of a stainless steel transducer. Nothing moves in the process, nothing can clog on the single rod, and the switch needs no calibration. It is built around an 8-amp DPDT gold flash relay, selectable in the field for high-level or low-level fail-safe action. Seven Star LLC is an independent supplier serving Oman and the GCC.

How the Magnetrol Echotel 910 detects liquid

The switch works at an ultrasonic frequency of 3 MHz. Two piezoelectric ceramic crystals, made of a material such as lead zirconate and sealed in epoxy at the tip, face each other across the transducer gap. When liquid fills the gap, the sound travels easily from the transmit crystal to the receive crystal, and the electronics see a signal. When the gap is dry, the signal is attenuated so strongly that the receiver cannot detect it, and the relay changes state. The sensitive point sits 0.25 inch, or 6 millimetres, from the end of the tip, so the switch can actuate very close to the bottom of a vessel or a sump.

Specifications of Magnetrol Echotel 910

Item Catalog value
Technology Ultrasonic contact, 3 MHz, 316 stainless steel transducer
Supply options 120 V AC, 240 V AC (plus 10 minus 15 percent, 50/60 Hz) or 24 V DC (plus or minus 10 percent)
Power consumption 2.5 VA nominal
Gold flash relay DPDT, 8 A at 120 or 240 V AC, 8 A at 24 V DC, 0.5 A at 125 V DC
Hermetically sealed relay DPDT, 5 A at 120 V AC, 240 V AC or 24 V DC
Repeatability 0.078 inch (2 mm)
Fail-safe Field selectable, high or low
Ambient temperature, electronics Minus 40 to plus 70 degrees C
Process temperature, transducer Minus 40 to plus 121 degrees C
Operating pressure 800 psig (55 bar)
Mechanical design pressure 1500 psig (103 bar)
Actuation length 1 to 96 inches in 1 inch steps, or 3 to 244 cm in 1 cm steps
Housing Cast aluminum, dual conduit, 3/4 inch NPT or M20, NEMA 4X/7/9
Shock and vibration ANSI/ISA-S71.03 Class SA1 and VC2

Reading the Magnetrol Echotel 910 order code

The model number is built from ten positions. The fourth selects the housing: A is aluminum with 3/4 inch NPT dual conduit and FM approvals, P adds ATEX and IECEx, and W is the M20 version. The fifth chooses English or metric length. The sixth sets the process connection, from 3/4 inch NPT, 1 inch NPT or 1 inch BSP up to 1, 1.5 and 2 inch ASME flanges in 150 or 300 pound classes. The seventh gives the supply and relay type, and the last three digits give the actuation length. Because the rest of the code depends on the vessel, confirm the full order code on the drawing before ordering.

How Magnetrol Echotel 910 differs from other Echotel switches

The compact Echotel 940 and 941 are economical ultrasonic switches in a lighter design, while the 961 and 962 are the single and dual point electronics for plant-wide use with sensor and electronics modules. The Echotel 910 is the one with the integrally mounted electronics, surface mount conformal coated circuit board and full hazardous area approvals from FM, CSA and ATEX, together with a long actuation length of up to 96 inches. If you need a short switch for a seal pot, the 910 is suitable; if you need separate sensing points on one probe, a 961 or 962 is the better pick.

Applications in Oman and the GCC

The catalog lists seal pot level, low level alarm, high level alarm, OEM and skid packages and pump protection. In Oman these map onto lube oil reservoirs, chemical injection skids, closed drain drums, small day tanks and the sumps of pumps that must not run dry. The no-moving-parts design suits applications where float switches would stick, and the hermetically sealed relay option helps in damp coastal plants.

Choosing an actuation point and orientation

The distance from the process connection to the sensing gap is the actuation length, and this single number decides where the relay changes state. For a low level alarm that protects a pump, measure from the connection down to the lowest liquid level you can allow and order that length. For a high level alarm, measure from the connection to the maximum permitted level instead. Horizontal side mounting is common in small vessels, because it makes the actuation point independent of the probe length, while top mounting suits tanks where a long rod can hang down. In both cases make sure the gap is not packed with sediment or covered by a layer of foam, since foam can look like a wet gap to an ultrasonic sensor. Where the liquid is viscous, mount the probe at an angle so that it drains.

Installation and set-up

Select the mounting position, which can be horizontal or vertical, and install the transducer so that the gap sits at the point where actuation is wanted. Orient the gap so that liquid drains from it freely. Pipe the conduit entries, connect the supply and relay contacts, and set the fail-safe jumper according to the safe action you need. No calibration is required, and the unit starts to work as soon as power is applied.

Service notes

The switch is well suited to unattended operation. Inspect the transducer tip at plant shutdowns, remove coatings that could bridge the gap and test the relay action by raising or lowering level. Spare electronics boards for the Echotel 910 are a common service item.

Ordering notes for Magnetrol Echotel 910

Give the full model number with housing, connection, supply, relay and actuation length. Mention the media, pressure, temperature and hazardous area classification so that the correct approval option can be checked.

Related items you may also need: Magnetrol 089-7259-001 Echotel 961 102-265 VAC Electronics Module | Magnetrol Z31-2883-001 HART Electronic Module for E4 Modulevel | Magnetrol Z30-9816-001 Wiring Board for Pulsar R80, General Purpose | All Magnetrol products.

Documents and quotation

The product catalog covering the Magnetrol Echotel 910 is attached to this page. Please send your RFQ with Magnetrol Echotel 910, the full model code, the quantity and your delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Magnetrol Echotel 910 Ultrasonic Liquid Level Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Echotel 910 Ultrasonic Liquid Level Switch

Answers from our engineering team on installation, compatibility and integration.

01What technology does the Magnetrol Echotel 910 use?
It uses ultrasonic contact sensing at 3 MHz across a gap in a 316 stainless steel transducer, with no moving parts and no calibration.
02What relay does the Magnetrol Echotel 910 have?
It has either an 8-amp DPDT gold flash relay or a 5-amp DPDT hermetically sealed relay, field selectable for high or low level fail-safe action.
03What are the temperature and pressure limits of the Echotel 910?
The transducer handles minus 40 to plus 121 degrees C at 800 psig operating pressure, with 1500 psig mechanical design pressure.
04What actuation lengths are available for the Echotel 910?
From 1 to 96 inches in 1 inch steps, or 3 to 244 cm in 1 cm steps, with minimum lengths that depend on the process connection.
05Which approvals apply to the Magnetrol Echotel 910?
The catalog lists FM, CSA and ATEX approvals for hazardous locations, with IECEx on the P and W housing codes.