Brand: Magnetrol
Magnetrol C25-1B10 Tall Cast Iron Float Level Switch
Description
Overview
Magnetrol C25-1B10 is the taller sibling of the C24 in the cast iron float chamber range, giving a much wider spread between switching points. It is intended for non-boiler industrial service, because the C models omit the brass chamber liner of the B24 and B25 boiler controls. A float, an attraction sleeve and a pivoted magnet translate liquid level into a snap switch action outside the pressure boundary. Seven Star LLC is an independent supplier serving Oman and the GCC.
The C25 is typically chosen for condensate receivers, flash tanks and holding tanks where operators want the high and low alarm points several inches apart so that the alarm does not chatter when the level wanders.
Magnetrol C25-1B10 key properties
- Cast iron float chamber
- 400 series stainless steel attraction sleeve
- 316L stainless steel float and 316 stainless steel trim
- Minimum specific gravity 0.84
- 250 psi at 406 F (17 bar at 207 C) working pressure
- 400 psi (28 bar) maximum pressure at 100 F
- Single or multiple switch mechanisms, with dry contact, hermetic or pneumatic choices
- Type 4X/7/9 aluminum switch enclosures for Class I Division 1 Groups C and D
Dimensions and levels that distinguish the C25
At a specific gravity of 1.0 and with a single switch mechanism, the datasheet gives C25 actuation levels of 3.69 inch (94 mm), 4.50 inch (114 mm), 4.13 inch (105 mm) and 4.88 inch (124 mm), each with a tolerance of plus or minus 0.25 inch (6 mm). Compare those with 0.69 to 1.69 inch for the C24. The C25 housing also needs 1 inch NPT conduit entry for electrical switches and 1/4 inch NPT for pneumatic ones, while the physical body is taller than the C24.
Magnetrol C25-1B10 versus C24-1B10
| Chamber and materials | Same cast iron body, 400 series sleeve, 316L float, 316 trim |
| Working pressure | Same, 250 psi at 406 F |
| Actuation levels C24 | 0.69, 1.56, 0.94, 1.69 inch |
| Actuation levels C25 | 3.69, 4.50, 4.13, 4.88 inch |
| Use | C24 for short spans; C25 where a wider differential or more clearance is needed |
How the float chamber switches
Inside the chamber a permanent magnet is carried on a pivoted actuator with an adjustment screw. When the float rises with the liquid, it lifts the attraction sleeve into the magnet field. The magnet then snaps against the non-magnetic enclosing tube and the switch changes state. On a falling level an Inconel spring pulls the magnet back and the contact returns. The enclosing tube is the static pressure barrier, so the electrical parts never touch the process fluid.
Because the action is a snap, the contacts do not creep slowly through the transfer point. That protects relay coils and pump contactors from the arcing that slow-moving contacts would cause, and it gives repeatable trip heights from one proof test to the next.
Up to three switch mechanisms can be stacked on the family for alarm, control and shutdown functions, although the actuation levels quoted in the datasheet are for a single mechanism, so consult the manufacturer data for multiple switches.
Switch options and electrical ratings
Series B and C snap switches are rated 15 A at 120 and 240 VAC, Series D handles 10 A at 120 VAC and 10 A at 24 VDC, and the hermetic Series F is rated 2.5 A at 120 VAC and 4 A at 24 VDC. The HS capsule gives 5 A at both 120 and 240 VAC. Pneumatic Series J and K mechanisms are for locations without electrical power, with a maximum process temperature of 400 F. Process temperature ratings are 450 F for Series B, C and D and up to 1000 F for hermetic types, but the cast iron chamber limits the service to 406 F.
Typical duty in Oman and the Gulf
Typical roles include condensate receiver control, day tank level, holding tank alarms, boiler feedwater pump control on non-boiler vessels and flash tank high level alarms. Plants with low pressure steam networks in desalination, food processing and district cooling often have vessels in this range. Because the wide spacing gives the control system a clear margin between low alarm, pump start and high alarm, the C25 is especially useful on receivers that are fed by intermittent condensate returns, where the level can move quickly and a short span would produce frequent alarms. The cast iron body also tolerates the cyclic temperature swings of a condensate system when the working limits are observed, and the stainless float and trim resist the mild corrosion found in treated water service.
Installing the Magnetrol C25-1B10
Use the dimension drawing to place the chamber connections against the vessel taps, with the cover side clear for removal and about 10 inches overhead. Support the piping so no strain reaches the cast iron body. Isolation valves in the connecting piping, if used, should be locked open in service. Wire the switch for the intended fail-safe action and test by running the level through each trip point, recording the measured levels against the design set points. If the process fluid is lighter than specific gravity 0.84, discuss an alternative chamber code before ordering, since the float will not be buoyant enough for reliable actuation.
Maintenance guidance
Periodic flushing prevents sludge from locking the float. Look for corrosion around the cast iron cover joint, replace gaskets if the cover is opened, and verify that the housing seal is intact. For spares, confirm the full order code on the nameplate and give the code to Seven Star LLC with the RFQ.
Related items you may also need: Magnetrol Z31-2858-001 PROFIBUS PA Electronic Module for Eclipse 706 | Magnetrol 032-6923-001 705/706 Adapter for Eclipse 706 Transmitter | Magnetrol 089-7827-011 LVDT Kit, Low Temperature, for E4 Modulevel | All Magnetrol products.
Documents and quotation
The datasheet for Magnetrol C25-1B10 is attached. Send an RFQ to Seven Star LLC stating the C25-1B10 suffix, electrical or pneumatic switch code, enclosure and quantity.
Datasheets & Documents
- Datasheet Magnetrol C25-1B10 Tall Cast Iron Float Level Switch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol C25-1B10 Tall Cast Iron Float Level Switch
Answers from our engineering team on installation, compatibility and integration.
01What makes the C25 different from the C24?
The C25 chamber is taller and its actuation levels range from 3.69 to 4.88 inches against 0.69 to 1.69 inches for the C24.
02Is C25-1B10 suitable for boilers?
The C models are meant for non-boiler industrial use; the B25 with a brass chamber liner is the boiler version.
03What is the working pressure of C25-1B10?
The datasheet gives 250 psi at 406 F (17 bar at 207 C) with 400 psi (28 bar) maximum at 100 F.
04Which switch types can be fitted to C25-1B10?
Dry contact Series B, C and D, hermetic Series F and HS, and pneumatic Series J and K mechanisms are offered.
05What float material does C25-1B10 use?
The float is 316L stainless steel, with 316 stainless steel trim and a 400 series stainless attraction sleeve.