Brand:

EUCHNER CMS-E-ER Evaluation Unit for CMS Read Heads

Description

Overview

The EUCHNER CMS-E-ER is the evaluation unit of the magnetically coded CMS system. It is a DIN rail module that reads signals from up to 30 CMS read heads, switches two safety relay contacts and one auxiliary contact, and offers a feedback loop for monitoring downstream contactors. Since the read heads themselves contain no electronics that need servicing, the module is the central brain of an arrangement that protects many doors with simple, sealed sensors. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the code EUCHNER CMS-E-ER means

CMS stands for the magnetically coded safety switch system, E marks the evaluation unit and ER names the version with two safety contacts, one auxiliary contact and a start function that can be set to automatic, monitored or not monitored. The article number is 099182. Read heads and actuators are separate parts, and the unit works with read heads that have Hall sensors, as the CMS-RH-AYA and CMS-RH-BYB types.

Specification of EUCHNER CMS-E-ER

Parameter Value
Read heads Up to 30 connectable
Safety contacts 13/14 and 23/24, two floating NO contacts
Auxiliary contact 31/32, one floating NC contact
Supply 24 V AC/DC, plus or minus 10 percent
Current consumption 10 to 110 mA at 24 V DC
Contact ratings AC-1 3 A at 230 V; DC-13 1.5 A at 24 V; AC-15 0.9 A at 240 V
Switching capacity up to 720 VA per safety contact; up to 240 V AC
Contact current range 10 to 3000 mA at 24 V DC (safety contacts)
External fuse 4 A gG for the safety circuit
Risk time up to 20 ms
Rating with one read head Category 4, PL e, PFH 2.5 x 10 to the minus 8
Rating with several read heads Up to Category 3, PL d, PFH 1 x 10 to the minus 7
Mechanical life 10 million cycles
Mounting TH 35 rail
Protection IP20 terminals, IP40 housing
Ambient 0 to plus 55 degrees C; housing polyamide PA6.6

How EUCHNER CMS-E-ER differs from other CMS evaluation units

There are four units in the range. The CMS-E-AR has one safety contact and can connect up to 30 read heads. The CMS-E-BR adds an auxiliary contact and a feedback loop, but only four read heads can be connected. The EUCHNER CMS-E-ER provides two safety contacts, one auxiliary contact and the feedback loop with up to 30 read heads. The CMS-E-FR, finally, keeps the two safety contacts and adds six monitoring outputs, but limits the number of read heads to six. If every head must be diagnosed individually, the FR is the right unit; if you want the most heads on one unit, ER or AR is chosen.

Category versus number of read heads

The data sheet is explicit that the achievable rating depends on how the unit is used. With a single read head the unit reaches Category 4 and PL e, while with more than one head the maximum is Category 3 and PL d. This is because several heads in series cannot be diagnosed individually by the unit, so a fault in one head may be masked by another. Designers should decide whether the risk requires PL e, in which case one head per unit is the choice, or whether PL d with many heads is acceptable.

Where the CMS system is used in Oman and the GCC

The CMS idea is popular with plants that have long runs of covers or many small hatches, such as conveyor lines, packaging lines, parcel sorters, food plants and bottling halls. The read heads are insensitive to dirt and withstand wash-down, and the evaluation unit sits in a cabinet. Replacement is straightforward since the read heads carry no settings.

Wiring and start behaviour

Connect the supply to A1 and A2, the heads to the designated terminals, and the safety contacts 13/14 and 23/24 to the load circuit or to a downstream safety logic. The start behaviour can be automatic, monitored or not monitored, set by wiring. A feedback loop can monitor external contactors; if it is not used, it must be bridged. Protect the safety contacts with a 4 A gG fuse, and use conductors of 0.14 to 2.5 square mm.

Commissioning

With all doors closed the unit should switch the safety contacts on, and opening any door must switch them off within the risk time of up to 20 ms. At low approach speed in the Z direction, the time offset between the heads can cause nuisance faults, so the approach direction Z should be avoided if the speed is low, as the manufacturer advises.

Planning a multi-door installation

The strength of the EUCHNER CMS-E-ER unit is the number of doors it can supervise, but with that strength comes a design choice. All heads supervised by the unit act on the same pair of safety contacts. If you need a precise indication of which door is open, a unit with individual monitoring outputs is more suitable, while for a long row of identical covers on a conveyor a single shared unit is economical and keeps the cabinet small. Use the auxiliary contact 31/32 to signal that the safety contacts are open, and wire the feedback loop through the normally closed contacts of the contactors that the unit controls.

With a single read head the combination reaches category 4. For a run of several heads, check the required performance level of the machine. If PL e is demanded, split the chain into separate units or consider switches with their own diagnostics. The mechanical life of the relay outputs is 10 million cycles, and the switching capacity of 720 VA per contact allows small contactors to be driven directly, although a suppression network on inductive loads prolongs contact life.

Service

Check terminals during shutdowns, and read the LEDs: one shows the supply and two show the state of the read head channels. Keep the cabinet within 0 to 55 degrees C. Replace the unit if the contacts are welded or if internal fuses have triggered repeatedly.

Ordering notes

Send the complete code and the number and type of read heads. Read heads, actuators, spacers and cables are separate items. We can quote the full set for a machine.

Related items you may also need: EUCHNER ESM-BT411 Safety Relay with Time-Delayed Contacts | EUCHNER RPS-M-2131SR175M Emergency Stop Rope Pull Switch | EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set | All EUCHNER products.

Documents and quotation

The manufacturer operating instructions for the CMS evaluation unit are attached to this page. Send your RFQ with EUCHNER CMS-E-ER, the quantity and the destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet EUCHNER CMS-E-ER Evaluation Unit for CMS Read Heads Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CMS-E-ER Evaluation Unit for CMS Read Heads

Answers from our engineering team on installation, compatibility and integration.

01How many read heads can the EUCHNER CMS-E-ER evaluate?
It can connect up to 30 CMS read heads, but the achievable category drops from 4 to 3 when more than one read head is connected.
02What contacts does the EUCHNER CMS-E-ER provide?
It has two floating safety NO contacts, 13/14 and 23/24, and one floating auxiliary NC contact, 31/32.
03What is the supply voltage of the CMS-E-ER?
It is supplied with 24 V AC/DC, plus or minus 10 percent, and draws 10 to 110 mA at 24 V DC.
04How does the CMS-E-ER differ from the CMS-E-FR?
The FR adds six monitoring outputs but connects only six read heads, while the ER connects up to 30 read heads.
05How is the CMS-E-ER mounted?
It clips onto a TH 35 mounting rail, with IP20 terminals and an IP40 polyamide housing for cabinet use.