Panels fed from mains instead of a 24 V rail can use Bürkert 134098, the 230 V 50 Hz member of the Bürkert Type 6011 miniature valve row. It has a brass body, a G⅛ port, a 2.0 mm orifice and a water Kv value of 0.11 m3/h, and it is rated for 0 to 8 bar. It is direct-acting and normally closed, with an FKM seal. Seven Star LLC is an independent supplier serving Oman and the GCC.

Data table of Bürkert 134098

Parameter Value
Article 134098, brass body, G 1/8
Orifice and Kv 2.0 mm, 0.11 m3/h
Voltage 230 V 50 Hz
Pressure range 0 to 8 bar
Family Bürkert Type 6011, direct-acting 2/2-way plunger valve
Circuit function A, normally closed
Seal FKM
Coil Epoxy, thermal class H, tolerance plus or minus 10 percent
Duty cycle 100 percent for a single valve
Medium Technical vacuum, neutral gases and liquids
Medium temperature minus 10 to plus 100 degrees C
Viscosity max. 21 mm2/s
Ambient temperature max. plus 55 degrees C
Electrical connection Plug contacts form C, DIN EN 175301-803, for cable plug Type 2516
Protection IP65 with cable plug
Weight approx. 125 g

What the 230 V coil changes for Bürkert 134098

An AC coil develops its highest force at the start, when the core is open, and it allows higher pressure than a DC coil of the same size. The ordering chart shows this clearly: the 2.0 mm orifice is rated 0 to 4.5 bar on 24 V DC but 0 to 8 bar on 24 V 50 Hz, 110 V and 230 V. On the other hand AC coils hum slightly, draw an inrush and can burn out if the core is blocked, so this version suits clean media and well-aligned installation.

Differences from nearby articles

Article 134095 is the 24 V DC version of the same orifice, with a lower pressure range of 0 to 4.5 bar. Article 134096 is 24 V 50 Hz, and 134097 is 110 V. Compared with the 1.6 mm articles 134071 and 134094, 134098 has a larger orifice with a Kv higher by about 80 percent, which suits slightly higher flow in the same small body.

Manifold and sub-base mounting

The Type 6011 can be ordered with threaded ports, with M5 ports or in a sub-base variant that uses a Bürkert specific flange design for compact manifolds. When valves are packed side by side the duty rating changes: the data sheet gives intermittent operation of 60 percent over 30 minutes, or 100 percent with the 2 W coil on request. Plan heat dissipation accordingly, and take care that no oil, grease or silicone is used as an installation aid, because the data sheet specifically prohibits it.

Cable plugs and electrical practice

Protection to IP65 is achieved only with a cable plug fitted. The family offers DIN EN 175301-803 form C contacts for cable plug Type 2516, and industry standard form B contacts for cable plug Type 2507. Neither plug is included with these valves, which are supplied complete with coil and FKM seal but without a plug, so add the right plug to your order. Coil voltage tolerance is plus or minus 10 percent, so supplies near the lower limit can leave the valve slow or unreliable on a hot day.

Vacuum and low-pressure notes

Because the plunger is lifted directly, the valve operates down to technical vacuum, which makes it a good choice for gas sampling pumps and degassing lines. At very low pressure, leakage through the seat depends on seal condition, so choose the analytical variant for critical sampling and keep the medium free from condensate. For liquids at low pressure, the small Kv limits flow, so calculate the flow before choosing the orifice.

Use in pneumatic and fluid circuits

Mains-voltage miniature valves are used in coffee and vending machines, small boilers, spraying and rinsing systems, laboratory equipment and pneumatic pilot circuits where a 24 V supply is not available. Ensure compliance with local electrical safety rules for mains voltages near wet areas, and use properly earthed cable plugs.

Mains voltage safety for Bürkert 134098

A 230 V coil carries live voltage at the cable plug, so installation must follow local electrical regulations. Use a plug with a proper earth connection if provided, keep the cable entry sealed, and never work on the valve with the supply connected. In wet or washdown areas, protect with a residual current device. The coil insulation class H handles heat, but mains wiring in hot cabinets needs cable rated for the temperature.

In machine builds, use a switched supply with a fuse sized for the coil’s inrush rather than its holding value.

What to include in an RFQ for Bürkert 134098

State the article number, the quantity, the medium and the pressure, and tell us the plug type and whether you need it. Mention the local supply voltage and frequency, since a 230 V 50 Hz coil is not suitable for 60 Hz networks or 240 V without confirmation. We will confirm availability and lead time for delivery to Oman and the GCC.

Where the 2.0 mm 230 V version is used

Typical places include small boilers, rinsing and spraying units, coffee and vending equipment, laboratory washers and pneumatic pilots on mains-powered machines. It is also used in test rigs where a variable AC supply is available.

Delivery notes for Bürkert 134098

The brass valve is supplied with its 230 V coil and FKM seal, without a cable plug, and the data sheet is attached to this page. Keep the port caps on until installation. Tell us about any special requirements such as certificates or specific packaging for shipment to Oman, and we will include them in the quotation before the order is confirmed.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Bray 630250-21522536 S63 Solenoid Valve 240 VAC Single Coil | All Bürkert products.

Documents and quotation

The Type 6011 data sheet containing Bürkert 134098 is attached with dimensions and ordering charts. Send an RFQ with part number 134098, quantity and delivery location in Oman or the GCC, and add cable plug Type 2516 or 2507 if required.

Other Models in the 6011 Range

Seven Star LLC supplies models from the 6011 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 134071 Type 6011 Brass Miniature Solenoid ValveSolenoid ValvesView details
Bürkert 134103 Type 6011 Stainless Miniature Solenoid ValveSolenoid ValvesView details
Bürkert 134098 Type 6011 230V Miniature Solenoid ValveSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 134098 Type 6011 230V Miniature Solenoid Valve Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 134098 Type 6011 230V Miniature Solenoid

Answers from our engineering team on installation, compatibility and integration.

01What voltage does Bürkert 134098 use?
This article is the 230 V 50 Hz version of the G 1/8 brass valve with a 2.0 mm orifice.
02What pressure range applies to 134098?
The ordering chart gives 0 to 8 bar for the 230 V 50 Hz version, higher than the 4.5 bar of the 24 V DC version.
03What is the Kv value of Bürkert 134098?
The water Kv value is 0.11 m3/h with a 2.0 mm orifice and G 1/8 port.
04Is 134098 direct-acting?
Yes, it is a direct-acting plunger valve of circuit function A, normally closed, so no minimum pressure difference is needed.
05Does Bürkert 134098 come with a cable plug?
No. A cable plug Type 2516 or 2507 must be ordered separately.