Brand: KRACHT
KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min
Description
KRACHT VCA 5 K5F4R1SH is the largest VCA size
KRACHT VCA 5 K5F4R1SH covers the widest range of the VCA family, from 1.00 to 200 l/min, with a geometric tooth volume of 5.222 cm3 and a pulse density of 191.50 per litre. It uses ball bearings, an aluminium housing with steel gears and a pipe connection.
Where the smaller VCA sizes serve dosing and lubrication, the size 5 is built for main oil lines such as engine test cells, gearbox filling and hydraulic circuit analysis. At 6.0 kg it is the heaviest of the aluminium series.
Because the unit passes up to 200 l/min, the displacement principle shows its strengths: no flow conditioners, no straight inlet runs and virtually no pulsation, so the meter can be placed right behind a pump or a filter housing. The pulse frequency at the top of the range is considerable, about 640 pulses per second at 200 l/min, which is still easy for a PLC high-speed counter but should be checked against the input specification of simpler digital input cards.
Data sheet values for VCA 5 K5F4R1SH
| Parameter | Value |
|---|---|
| Type code | VCA 5 K5F4R1SH |
| Geometric tooth volume | 5.222 cm3 |
| Measuring range | 1.00 to 200 l/min |
| Measuring unit starting at | 0.1 l/min at 20 mm2/s |
| Resolution | 191.50 pulses per litre |
| Maximum pressure | 100 bar |
| Weight | 6.0 kg |
| Bearing | Ball bearing |
| Housing / gears | Aluminium / steel |
| Seals | FKM |
| Typical accuracy | plus/minus 1.0 percent from 20 mm2/s |
| Maximum pressure loss | 16 bar |
| Viscosity | up to 4,000 mm2/s |
| Media temperature | -10 to 80 C |
| Supply | 12 to 30 V DC |
| Output | PNP / NPN square wave |
| Protection | IP 65 |
The datasheet also provides pressure drop curves for sizes 2 and 5 on one page. At 200 l/min and low viscosity the loss is moderate, but with thick cold oil it approaches the 16 bar limit, so plan the line pressure for the coldest case and size the pump accordingly.
Where VCA 5 K5F4R1SH differs from the VCA 2 and VCG 2
The step up from size 2 shows clearly in the numbers. Pulse density drops from 500 per litre (VCA 2) to 191.5. Weight rises from 1.9 kg to 6.0 kg. Maximum range grows from 65 to 200 l/min, and the pressure rating falls from 200 bar to 100 bar, which is the lowest of the series. The cast iron VCG 2 keeps its 350 bar at only 65 l/min.
Unlike the VCA 2, which uses a multi-layer plain bearing, size 5 uses ball bearings, and the measuring unit starts at 0.1 l/min at 20 mm2/s instead of 0.04 l/min at 100 mm2/s.
Specifically, a Gulf power station can use this meter to report oil flow to a bearing header of a gas turbine auxiliary skid, an oil terminal can use it for blending additive packages into a main line, and workshops can use it as the master meter on a transmission test bench. In every case the single-channel pulse train is easily accepted by a plant PLC or a KRACHT display unit.
The upper temperature limit of 80 C for media means that hot oil above that figure should be handled by a cast iron meter. If the line operates close to the limit, include a margin for peak temperatures, because the FKM seals and the pre-amplifier are both specified only up to that value.
Applications in oil and gas, power and manufacturing
Large turbine and compressor lube oil headers, hydraulic power unit return lines, fuel supply loops of gas engines and gearbox oil filling stations all fit within 200 l/min. For Gulf operators, the combination of ball bearings and a wide viscosity ability up to 4,000 mm2/s suits cold start conditions with thick oil.
The 100 bar limit keeps it away from high-pressure hydraulics; select the VCG 2 or other cast iron meters for those jobs.
Selection and installation notes for VCA 5 K5F4R1SH
With 6.0 kg and a pipe connection the meter should be supported independently of the tubing. Mount it in any position; flow can go in either direction. Keep an eye on pressure loss, which grows with viscosity and flow and must stay within 16 bar.
Wire the Hirschmann socket with pin 1 supply, pin 2 channel 1 and pin 4 0 V; the single-channel output delivers the volume only.
Compared with a turbine meter, a gear meter reads correctly with viscous oil, which is why you would choose this meter for lubricants up to 4,000 mm2/s and the KRACHT TM turbine series for thin liquids up to 50 mm2/s. The two families complement each other, and the choice is mainly decided by viscosity.
Operation and care of VCA 5 K5F4R1SH
Fill gradually, vent air and avoid pressure surges. Because the gears are lubricated by the measured medium, never run the meter without liquid. If pressure loss at a given flow rises, clean the filter before suspecting the meter.
Record the pulse constant of 191.50 per litre during commissioning and keep the factory test data with the plant file. If your controller needs a rate in litres per minute, divide the pulse frequency in hertz by 191.5 and multiply by 60. For billing-style totals, use a counter with enough digits so that it does not roll over during long runs.
Ordering notes and FAQ summary
Order with the full code. Related meters: VCA 2 M4F4P1SH, VCA 0.1 K5F4R1SH and VCG 2 M1F1P2SH. The FAQ below gives range, pressure and resolution at a glance.
Documents and quotation
The VCA/VCG datasheet is attached. Send VCA 5 K5F4R1SH and the quantity as an RFQ to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht Vca Gear Range
Seven Star LLC supplies models from the Kracht Vca Gear range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min | Turbine & Positive Displacement Flowmeters | You are viewing this model |
| KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar | Turbine & Positive Displacement Flowmeters | View details |
Datasheets & Documents
- Datasheet KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200
Answers from our engineering team on installation, compatibility and integration.
01What is the flow range of KRACHT VCA 5 K5F4R1SH?
1.00 to 200 l/min, with the measuring unit starting at 0.1 l/min at 20 mm2/s.
02What pressure does VCA 5 K5F4R1SH support?
Maximum pressure is 100 bar, the lowest rating in the VCA/VCG size table.
03What is the resolution of VCA 5 K5F4R1SH?
191.50 pulses per litre from a tooth volume of 5.222 cm3.
04What bearing and housing does VCA 5 K5F4R1SH have?
Ball bearings with an aluminium housing and steel gears (codes K and 5).
05How heavy is VCA 5 K5F4R1SH?
The datasheet lists a weight of 6.0 kg for this aluminium-housing meter, so support it properly.