Brand: Beamex
Beamex 8006030 ePG Li-ion Battery Pack 14.4 V
Description
Beamex 8006030 battery pack for the ePG pump
Beamex 8006030 is the Li-ion battery pack for the Beamex ePG electric pressure pump. It has a USB Type-C connector, a rating of 14.4 V and a capacity of at least 2,600 mAh. The label on the pack in the product picture reads Battery Pack RB-14 for ePG and shows 14.4 V, 3.4 Ah, 48.96 Wh in a 4S1P arrangement, while the maker’s stated minimum capacity is 2,600 mAh. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
The ePG is a portable, hand-held, battery-powered pump that generates pressure and vacuum without hand pumping, so the 8006030 pack is the single consumable that decides how long a technician can work away from mains power.
Battery and charger data
| Item | Detail |
|---|---|
| Part number | 8006030 |
| Description | Battery pack ePG, Li-ion |
| Voltage | 14.4 V |
| Capacity | At least 2,600 mAh |
| Connector | USB Type-C on the pack |
| Minimum charger | USB Type-C PD 2.0/3.0, Profile 4, 20 V / 2.25 A / 45 W |
| Charging window | 0 to 45 degrees C |
| Over-temperature stop | ePG stops when internal temperature exceeds 60 degrees C |
| First charge | At least 4 hours before first use if not fully charged |
| Auto switch-off | After 60 minutes unused, or when only a few percent charge remains |
| ePG pressure range | Minus 0.85 to 20 bar / minus 12.4 to 300 psi |
| ePG weight | About 2.3 kg / 5 lb |
| ePG operating temperature | 0 to 50 degrees C |
For planning purposes the pack energy shown on the label of the pictured unit is 48.96 Wh, but order and test against the specification of 14.4 V and at least 2,600 mAh. Keep each 8006030 pack paired with the pump serial in your records if your quality system tracks reference equipment.
Field-replaceable by design
The maker highlights that the battery can be quickly charged either inside the pump or separately, and that a charged spare can be exchanged in the field. The pack carries a status indication: pressing the button shows the number of lit LEDs for battery status, and a green LED lights when the pack is connected to a suitable charger.
A slot on the pack locks the 8006030 into the pump. In the vertical position the pack is locked; turning the slot to horizontal unlocks it, and a screwdriver, washer or coin can be used for turning. The manual says to always lock the pack so it cannot fall out, and to push it gently inside to make the lock move easily.
How 8006030 differs from other ePG spares
ePG spares address different parts. The mesh filter set 8006160 protects the output port with 36 micron filter elements, the piston seal service kit 8006130 and the non-return valve kit 8006145 are pneumatic repairs, and the shoulder strap 8006110 and hard cases are carrying items. 8006030 is the only electrical spare. Unlike the batteries of the MC6 family, such as 8081785 for MC6 or 8075644 for MC6-Ex, it is built around the ePG’s own 14.4 V USB-C pack.
Operating points that affect battery life
The ePG vents itself and turns off automatically after 60 minutes unused, which saves charge. The manual lists generation times: from 0 to 20 bar in less than 110 seconds and from 0 to minus 0.85 bar in less than 45 seconds into a volume of 20 ml. Larger test volumes demand more energy, so a spare pack is wise for long field rounds.
Outside the 0 to 45 degrees C charging window the pack cannot be charged, which matters in Gulf summers if a vehicle is left in the sun. If the internal temperature rises above 60 degrees C the pump stops until it cools.
The manual’s troubleshooting section for this part is straightforward: the symptom is Battery Pack is not charged, the indication is the green LED in the pack staying off, and the solution is the correct charger. A second entry covers an ePG that does not start even though the battery is full and the pump feels very warm; it simply needs to cool down, and the manual notes that return to service takes several minutes.
Troubleshooting the pack
If the green LED stays off, the charger is probably the wrong type. Use the charger that came with the ePG, or one that meets the stated minimum: USB Type-C, PD 2.0/3.0, Profile 4 at 20 V, 2.25 A, 45 W. If the pump feels very hot and will not start even when the battery is full, let it return to normal temperature and then try again.
Upon delivery the battery may not be fully charged, so charge at least four hours before the first use.
A frequent field scenario is a two-pack routine: one pack in the pump, one charging from a vehicle or site USB-C supply that meets the stated minimum. Because the ePG shows status with LEDs, the technician can decide at the instrument whether to swap packs before starting a long calibration list.
Applications in Oman and the GCC
Electric pressure generation is useful where technicians climb to remote transmitters at wellsites, pipeline stations and water tanks. The 2.3 kg ePG plus a spare pack replaces a heavier hand pump set for pneumatic ranges up to 20 bar, and it frees one hand to read the calibrator.
Handling and storage
Store the 8006030 pack within the pump storage range of minus 20 to 60 degrees C, avoid exposing it to heat, and keep USB-C ports clean. Do not charge with an unsuitable power source. When transporting by air or road, observe the usual rules for lithium-ion packs.
Dispose of worn packs through a battery recycling channel in accordance with the country-specific regulations that the manual’s disposal chapter refers to, rather than with general waste.
Documents and quotation
The ePG user manual is the datasheet for Beamex 8006030. To request a quotation, send an RFQ to Seven Star LLC with part number 8006030 and the quantity required.
Datasheets & Documents
- Datasheet Beamex 8006030 ePG Li-ion Battery Pack 14.4 V Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8006030 ePG Li-ion Battery Pack 14.4 V
Answers from our engineering team on installation, compatibility and integration.
01What are the electrical specifications of Beamex 8006030?
Li-ion, 14.4 V, at least 2,600 mAh, with a USB Type-C connector on the pack.
02What charger can be used?
A USB Type-C PD 2.0/3.0 charger meeting Profile 4 at 20 V, 2.25 A and 45 W, or the charger supplied with the ePG.
03Can the battery be charged outside the pump?
Yes. The maker states the pack can be charged inside the pump or separately, so a spare can be charged in advance.
04When will the pack not charge?
Outside 0 to 45 degrees C the pack cannot be charged, and above 60 degrees C internal temperature the ePG stops as a precaution.
05Does the ePG switch off by itself?
Yes. It vents and turns off after 60 minutes unused, or when only a few percent charge remains.