Brand:

MTL SD32T3 Three-Terminal Surge Protection Device

Description

Why a three-terminal device: the SD32T3 explained

Many field instruments, from vibration probes to 3-wire pressure transmitters, use one conductor for power, one for the signal and a shared return. Protecting each wire with a separate two-terminal device leaves gaps, because a surge can find a path between wires that no individual protector covers. The MTL SD32T3 puts all three conductors on one hybrid circuit, so the protection is common to supply, signal and return, and the clamping level is lower than the sum of separate parts.

It belongs to MTL’s SD range of ultra-slim DIN-rail surge protection devices, which are clamped to the rail so that the rail provides the earth connection automatically.

SD32T3 key figures

Model SD32T3
Type 3-terminal surge protection device, separately powered 3-wire loops
Nominal voltage 32 V dc / 22 V ac
Nominal current 400 mA
Series resistance 2.2 ohm (signal)
Maximum leakage current 5 microamps
Rated voltage (MCOV) 36 V
Protection level at 1 kV per microsecond below 45 V
Residual voltage at nominal discharge current 75 V
Bandwidth 720 kHz
Maximum surge current 20 kA (8/20 microseconds)
Nominal discharge current 3 kA (8/20 microseconds)
Lightning impulse current 2.8 kA (10/350 microseconds)
Response time below 1 ns
Terminals 2.5 mm2 (12 AWG)
Weight about 70 g

How SD32T3 differs from SD32, SD32X and SD32R3

Four 32 V models share the SD range and each has a purpose. The SD32 has a 4.2 ohm series resistance and a fuse-disconnect feature, suited to analogue loops that need isolation for commissioning. The SD32X trims the resistance to 2.2 ohm without the disconnect. The SD32R3 adds a third terminal with 50 MHz bandwidth and 10 ohm series resistance for high-speed signals. The SD32T3 sits between them: three terminals, 2.2 ohm, 720 kHz and 75 V residual voltage, optimised for powered 4-20 mA loops.

In short, choose the SD32T3 when a 3-wire sensor needs one device, the SD32X for a 2-wire transmitter and the SD32R3 for fast data.

Intrinsic safety certificate and limits

For intrinsically safe circuits the SD32T3 carries Ex ia IIC T4 Ga certification, valid for ambient temperatures from minus 30 degrees C. The entity values to enter into the loop calculation are Li of 0.22 mH and an input current that falls as input voltage rises: 260 mA for Ui up to 20 V, 175 mA for Ui up to 26 V, 140 mA for Ui up to 28 V and 65 mA for Ui up to 60 V. The device can also be installed in Zone 2 or Division 2 circuits without changing their safety, and the IS working power rating Pi is 1.0 W between minus 30 and plus 75 degrees C.

Typical placements for SD32T3 in Oman and GCC sites

Vibration sensors on compressors, pumps and gas turbines are the obvious case, since probes with 3-wire outputs are widespread in rotating machinery monitoring at oil, gas and power plants. Loop-powered pressure transducers with separate supplies in desalination and water pumping stations are another. The datasheet advises that the protector sits no more than one metre from the sensor, ideally in the junction box.

Outdoor plants with lightning exposure, such as flammable-liquid storage tanks, effluent treatment and gas pipelines, are the places where IEC 60079-14 stresses surge protection.

Installation points for the SD32T3

Clip onto 35 mm top-hat rail, 7.5 or 15 mm deep, and the rail forms the earth. Connect the sensor to the Protected Equipment terminals and the field cable to the Field terminals; the datasheet warns that the sensors go to the protected side, not the field side. Maintain a bond of at least 4 mm2, or a short flat braid, between the sensor housing and the steelwork so the voltage difference stays below the transmitter’s insulation rating.

Mount the SD32T3 on the field wiring side of any barrier or isolator, and keep 50 mm clearance between safe-area and hazardous-area terminals by using separate rails.

Maintenance and spares for SD32T3

The unit is passive and needs no calibration. Inspect the rail earth and terminals at shutdowns, and replace after a heavy lightning event, since the datasheet quantifies the impulse durability at 10 kA and the overstressed fault mode at 12 kA. Tagging accessories such as TAG57 strips and BRI7000 identifiers help keep loops identified. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Budgeting a 3-wire loop with the SD32T3

Consider a vibration probe system powered at 24 V dc through a 3-wire cable. The SD32T3 rating of 32 V dc leaves 8 V of headroom above the supply, and its rated voltage MCOV of 36 V means no conduction occurs until the line exceeds that value. Series resistance of 2.2 ohm in the signal path costs about 44 millivolts at 20 mA, which is invisible to a 4-20 mA input. Leakage is below 5 microamps, so there is no meaningful error even on the lowest 4 mA reading.

The 720 kHz bandwidth is far higher than the 25 kHz of the standard SD32, which suits fast vibration-type signals. The protection level of under 45 V at 1 kV per microsecond is well below the damage voltage of typical 24 V sensor electronics, and the 75 V residual voltage at nominal discharge current quantifies what the sensor sees during a 3 kA surge.

If the plant’s sensors are wired 4-wire, with separate power and signal pairs, the better choice is two SD32X units, one for the supply and one for the signal.

Documents and quotation

The SD range datasheet includes the approvals schedule and installation guidance. Send an RFQ stating SD32T3, quantity and your delivery location in Oman or the GCC.

Other Models in the MTL SD Surge Range

Seven Star LLC supplies models from the MTL SD Surge range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MTL SD07R3 Low-Voltage 3-Terminal Surge ProtectorIsolator & BarrierView details
MTL SD32T3 Three-Terminal Surge Protection DeviceIsolator & BarrierYou are viewing this model
MTL SD275X 240 V AC High-Current Surge ProtectorIsolator & BarrierView details
MTL SDPSTN Telephone Line Surge ProtectorIsolator & BarrierView details
MTL SDRTD 3-Wire RTD Surge Protection DeviceIsolator & BarrierView details
Datasheets & Documents
  • PDF Datasheet MTL SD32T3 Three-Terminal Surge Protection Device Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL SD32T3 Three-Terminal Surge Protection Device

Answers from our engineering team on installation, compatibility and integration.

01What is the SD32T3 designed to protect?
Separately powered 3-wire 4-20 mA loops and vibration sensors. All three conductors are protected inside one unit, so the hybrid circuit is common to the supply, signal and common wires.
02What are the main ratings of the SD32T3?
Nominal voltage 32 V dc or 22 V ac, nominal current 400 mA, series resistance 2.2 ohm per line on the signal path, maximum surge current 20 kA at 8/20 microseconds and a response time under 1 ns.
03Does the SD32T3 carry ATEX certification?
Yes. The SD**T3 types are certified Ex ia IIC T4 Ga for intrinsically safe circuits in Zones 0, 1 or 2, with Li of 0.22 mH and input current limits that depend on Ui (260 mA up to 20 V, 140 mA up to 28 V, 65 mA up to 60 V).
04What bandwidth does the SD32T3 offer?
The table lists 720 kHz for the SD32T3, which is much higher than the 25 kHz of the standard SD32 but lower than the 50 MHz of the R3 types.
05How does it differ from the SD32X?
The SD32X is a 2-wire protector with a 25 kHz bandwidth, 60 V residual voltage and fuse-free low resistance. The SD32T3 adds the third terminal and a 75 V residual voltage.