Brand:

MTL MTL5501-SR Fail-Safe Switch Interface with LFD, SIL3

Description

MTL5501-SR overview

The MTL5501-SR connects a fail-safe switch or proximity detector in the hazardous area to an isolated fail-safe electronic output in the safe area, and adds relay contacts that signal line faults. It is made for approved fail-safe sensors in loops that have to reach SIL3 under IEC 61508.

The MTL5501-SR is part of the MTL5500 range of DIN-rail mounted intrinsically safe isolators from MTL, a brand of Eaton. As a single-channel module, it is a fail-safe switch/proximity detector interface that clips onto a standard 35 mm rail, with plug-in terminals for the hazardous-area and safe-area wiring. Because many MTL5500 numbers look alike, this page repeats the facts taken from the manufacturer datasheet so that engineers can confirm that the MTL5501-SR matches their loop before sending an enquiry.

Key features of the MTL MTL5501-SR

  • Fail-safe electronic output of nominal 24 V, with a load of 750 ohm to 10 kilohm
  • Line fault detection relay: contacts open when a line fault is found
  • Sensor current windows defined for normal, broken-line and shorted-line states
  • Highest level in a single in-line subsystem is SIL3 (IEC 61508-2)
  • Three LEDs for power, channel status and line fault
  • Fully galvanic isolation: 250 V rms between safe-area and hazardous-area terminals, and 250 V rms between safe-area circuits and the power supply
  • Powered from 20 to 35 V dc, with an optional Powerbus system to share the supply across a row of modules

MTL5501-SR technical specifications

Parameter Value
Model MTL5501-SR
Range MTL5500 DIN-rail isolators
Supply voltage 20 to 35 V dc
Isolation 250 V rms tested at 1500 V rms minimum between safe and hazardous terminals; 250 V rms between safe-area circuits and supply
Terminals accept conductors up to 2.5 mm squared, stranded or single-core
Mounting 35 mm T-section DIN rail (7.5 or 15 mm) to EN 50022
Ambient temperature minus 20 to plus 60 C operating; minus 40 to plus 80 C storage
Humidity 5 to 95 percent relative humidity
Weight approximately 150 g
EMC to EN 61326 and NE21
Location of module safe area
Number of channels One
Voltage applied to sensor 8.6 V dc maximum from 1 kilohm
Output ON window sensor current 2.9 mA to 3.9 mA (normal, LFD contacts closed)
Output OFF, normal sensor current below 1.9 mA or above 5.1 mA
Broken line sensor current below 50 microamps (output off, LFD contacts open)
Shorted line sensor resistance below 100 ohm (output off, LFD contacts open)
Fail-safe output on / off 24 V nominal / 0 V, maximum below 5 V dc
Output load 750 ohm to 10 kilohm
Maximum on-state current 25 mA at 750 ohm
Short-circuit current 30 mA
LFD relay switching 0.3 A at 110 V ac or dc; 1 A at 35 V dc; 30 W / 33 VA
Supply current at 24 V 90 mA with 750 ohm load; 60 mA typical load
Power dissipation at 24 V 1392 mW with 750 ohm load; 1200 mW typical load
Safety description Uo plus or minus 9.7 V, Io 30 mA, Po 0.07 W, Ci 0 nF, Li 0 mH, Um 253 V
Functional safety SIL3 highest level in a single in-line subsystem

The module must be installed in the safe area, while the field device it serves may be located as the datasheet allows: Zone 0, IIC, T4 to T6 hazardous area where the connected device is suitably certified, or a Division 1, Group A hazardous location. Always read the current approval certificate on the manufacturer website for entity parameters, since the datasheet states that safety approvals can be revised.

Typical applications of the MTL5501-SR in Oman and the GCC

The manufacturer describes the MTL5501-SR as a fail-safe switch and proximity detector interface with line fault detection. In Gulf plants this duty usually means emergency shutdown and fire-and-gas trip loops in which an approved fail-safe sensor, such as a limit switch or proximity detector on a shutdown valve, feeds a safety logic solver.

  • Oil and gas: wellsites, gathering stations, gas plants and pipeline terminals
  • Utilities and power: turbine skids, fuel gas systems and boiler auxiliaries
  • Water and desalination: chemical dosing, treatment and pumping areas with flammable vapour risk
  • Petrochemical and manufacturing: solvent storage, loading bays and process units

Many older Gulf installations carry MTL5000 or MTL4000 series isolators. The datasheet states that the MTL5500 can replace MTL5000 units, so the MTL5501-SR is often requested as a like-for-like spare during shutdowns.

Selection and compatibility notes for the MTL5501-SR

Use the MTL5501-SR only with sensors approved for fail-safe duty; resistors must always be fitted in the sensor circuit when line fault detection is relied on. The dedicated safety manual from the manufacturer defines the proof-test and failure-rate data needed for a SIL verification calculation. For ordinary non-safety switch inputs the MTL5511 or MTL5514 are the usual choices.

Check the certificate of the field device against the safety description of the MTL5501-SR: the field device must tolerate the module output parameters, and the cable capacitance and inductance must stay within the permitted limits. The maximum safe-area voltage Um for the range is 253 V rms or dc.

Installation and commissioning of the MTL5501-SR

Clip the module onto the DIN rail and fit the supplied connectors. The hazardous-area plugs are the blue-labelled terminals, and the safe-area plugs and the power connector are separate parts. When crimp ferrules are used, the manufacturer recommends a metal tube length of 12 mm and a wire trim length of 14 mm. Keep intrinsically safe wiring segregated from other wiring as required by the installation code, and record the loop tag on the optional TH5000 tag holder. Check the supply is within 20 to 35 V dc before energising, and verify the loop with the module fitted before connecting the field cable.

Maintenance and spare parts

An isolator has no user-serviceable parts. Routine checks are limited to terminal tightness, LED status, supply voltage and a periodic loop test according to the plant procedure. A failed module should be replaced as a whole, and the plug-in connectors can be moved to the replacement. Related accessories listed in the datasheet include the HAZ and SAF connector plugs, the PWR5000 power connector, the PB-8T, PB-16T, PB-24T and PB-32T Powerbus kits and the THR2 rail.

Related products and ordering notes for the MTL5501-SR

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The MTL5500 range is the DIN-rail version of the family and the MTL4500 range is the backplane-mounted version, so quote the exact number MTL5501-SR when ordering, and mention any suffix, because a letter such as S, A, B, C, D or Y changes the function.

MTL5501-SR FAQ summary

Typical questions concern the function, the safety description and the supply of the MTL5501-SR. It is a fail-safe switch and proximity detector interface with line fault detection, powered from 20 to 35 V dc, with the figures listed in the table above.

Documents and quotation

The range datasheet for the MTL5501-SR is attached to this page. To request a quotation, send an RFQ with the part number MTL5501-SR, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.

Other Models in the MTL5500 Range

Seven Star LLC supplies models from the MTL5500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MTL MTL5544 2-Channel HART Repeater Power SupplyIsolator & BarrierView details
MTL MTL5546 4-20 mA HART Isolating Driver with LFDIsolator & BarrierView details
MTL MTL5501-SR Fail-Safe Switch Interface with LFD, SIL3Isolator & BarrierYou are viewing this model
MTL MTL5510 4-Channel Switch/Proximity Interface, Solid-StateIsolator & BarrierView details
MTL MTL5511 1-Channel Switch/Proximity Interface, Relay + LFDIsolator & BarrierView details
MTL MTL5513 2-Channel Switch/Proximity Interface, Solid-StateIsolator & BarrierView details
MTL MTL5514 1-Channel Switch/Proximity Interface, LFD RelayIsolator & BarrierView details
MTL MTL5516C 2-Channel Switch/Proximity Interface, Relay + LFDIsolator & BarrierView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL MTL5501-SR Fail-Safe Switch Interface with LFD,

Answers from our engineering team on installation, compatibility and integration.

01What is the MTL5501-SR used for?
The datasheet describes the MTL5501-SR as a fail-safe switch and proximity detector interface with line fault detection.
02What supply does the MTL5501-SR need?
It is powered from 20 to 35 V dc and is installed in the safe area, with 250 V rms isolation between the safe-area circuits and the supply.
03How is the MTL5501-SR mounted?
It clips onto a 35 mm T-section DIN rail and uses plug-in terminals that accept conductors up to 2.5 mm squared.
04Can the MTL5501-SR replace an older MTL5000 module?
The manufacturer states that the MTL5500 range can replace MTL5000 units, but check the function, suffix and certificate before ordering.
05How do I request a quotation for the MTL5501-SR?
Send an RFQ with the part number MTL5501-SR, quantity and delivery location in Oman or the GCC, and we will reply with availability and lead time.