Why the MTL7761Pac suits load cell circuits

Load cells and strain-gauge bridges are low-voltage, low-current sensors, so a barrier for them needs to disturb the measurement as little as possible while still keeping fault energy low. The MTL MTL7761Pac is the datasheet choice for that job in the MTL7700 range, listed for strain-gauge bridges with the application note load cell. Each of its two channels carries a 9 V, 350 ohm, 26 mA safety description, a combination that keeps the hazardous-area energy small enough for IIC gases.

Positioning among MTL7761 variants

Two close relatives exist. The MTL7761ac has a 90 ohm resistor and a 100 mA short-circuit figure, giving a lower 107 ohm end-to-end value. The MTL7761Pac raises the channel resistance to 350 ohm, which cuts the short-circuit current to 26 mA, and its end-to-end value becomes 378 ohm with a working voltage of 6.8 V instead of 6.0 V. The extra resistance matters for the high-impedance sense and mV output legs of a bridge, where little current flows and therefore little voltage is lost.

MTL7761Pac specification table

Model MTL7761Pac
Type two-channel non-polarised (ac) zener barrier
Safety description per channel 9 V, 350 ohm, 26 mA
End-to-end resistance 378 ohm
Working voltage Vwkg 6.8 V
Maximum voltage Vmax 7.5 V
Fuse rating 50 mA
Certified gas group IIC
Application strain-gauge bridges, load cells
Earlier equivalents MTL7061Pac, MTL7161Pac (MTL7000); MTL761Pac (MTL700)
Label colour grey, non-polarised
Working temperature -20 to +60 degrees C
Storage temperature -40 to +80 degrees C
Humidity 5 to 95 percent RH
Weight about 140 g

Reading the MTL7761Pac in a double-bridge circuit

The manufacturer shows a circuit for monitoring two load cells at the same time. An MTL7766Pac powers the bridges, and two MTL7761Pac barriers are used, one for the sense line and one for the mV output pick-off. Using 350 ohm bridges and a plus and minus 10 V supply, the quoted bridge excitation is 13.11 V for one bridge and 9.75 V for two. In that circuit the MTL7761Pac is used only for the sense and pick-off signals, where little current flows, so its higher series resistance has little effect.

The same design logic applies to single-bridge installations built from two or three barriers, where one MTL7761ac or MTL7761Pac reads the mV signal.

Industrial uses of MTL7761Pac in the Gulf

Weighing and batching in hazardous areas, tank and silo load cells at chemical plants, vessel-weighing on process skids and hopper scales at fertiliser and petrochemical sites are all situations where a bridge sensor sits in a classified zone and its signal needs a safe path to a transmitter or PLC input. Port and storage terminals in the GCC also use hazardous-area load cells on loading arms and bunkering systems.

Installation advice for the MTL7761Pac

Install on 35 mm DIN rail with an intact earth connection. Hazardous-area terminals carry blue labels and the removable plugs take up to 2.5 mm2 conductors, with a removal force above 15 N. Keep sense and excitation pairs together in the cable so that the cable parameters are known. After connection, confirm the bridge zero and span with a calibrated test load, since the 378 ohm path adds a small series resistance that a transmitter with high input impedance will ignore.

Never replace a barrier with one of a different safety description without rechecking the system documentation.

Care and spares for MTL7761Pac

Zener barriers have no moving parts, so maintenance is mostly visual: confirm labels, check terminal tightness at each shutdown and review the earth continuity. If the fuse has operated the module must be replaced, not repaired. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Selecting between MTL7761Pac and its neighbours

A short decision path helps. If the circuit is a bridge supply, use a powering barrier such as the MTL7766Pac or MTL7766ac. If the circuit is a sense or a mV pick-off, use an MTL7761 type. Among the sense barriers, the MTL7761ac has the 107 ohm end-to-end value and 100 mA fuse, while the MTL7761Pac has 378 ohm end to end and a 50 mA fuse. The MTL7764 family, at 12 V, 1 kilohm, 12 mA and 1050 ohm end to end, serves strain or level gauges with even higher resistance.

Finally, think about accuracy. The datasheet reports that leakage current falls by at least a decade for each volt below the working voltage over two decades. At the small signal levels of a strain gauge, leakage is negligible, so measurement error comes mostly from series resistance. For a 350 ohm bridge with the 378 ohm barrier channels used only for sensing, that error is small because the sense amplifier draws very little current.

Label each channel at both ends. If a bridge reads unstable, check the screen connection first and the earth rail second. Insert a meter in series only with the loop de-energised. When the barrier is suspected, measure its end-to-end resistance with the circuit isolated; around 378 ohm at 20 degrees C is expected, and an open circuit indicates an operated fuse.

The unused-channel question also arises. Both channels of an MTL7761Pac are identical, so a single module can serve two sensing legs of the same bridge, which saves rail space on a crowded panel. Keep the two legs of a pair in one multicore with a common screen, and terminate that screen at the safe-area earth only, as the manufacturer’s accessories (ETM7 earth terminals and ETL7000 DIN-rail earth terminals) are designed to support.

Documents and quotation

The MTL7700 range datasheet and the instruction manual INM7700 hold the full circuit and certification data. For pricing and availability, send an RFQ listing MTL7761Pac, the number of units and the delivery point.

Other Models in the MTL7700 Strain Gauge Range

Seven Star LLC supplies models from the MTL7700 Strain Gauge range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MTL MTL7766Pac Strain Gauge Supply BarrierIsolator & BarrierView details
MTL MTL7761Pac Load Cell Zener BarrierIsolator & BarrierYou are viewing this model
Datasheets & Documents
  • PDF Datasheet MTL MTL7761Pac Load Cell Zener Barrier Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL MTL7761Pac Load Cell Zener Barrier

Answers from our engineering team on installation, compatibility and integration.

01What is the safety description of the MTL7761Pac?
The table lists 9 V, 350 ohm, 26 mA for each channel, with an end-to-end resistance of 378 ohm, a working voltage of 6.8 V, a maximum of 7.5 V and a 50 mA fuse.
02Is the MTL7761Pac polarised?
No. It is an ac, non-polarised barrier, so either polarity of safe-area voltage can be applied at either end. The label colour for non-polarised barriers is grey.
03What is its MTL7000 series equivalent?
The correlation table links the MTL7761Pac to the MTL7061Pac and MTL7161Pac in the MTL7000 range, and to the MTL761Pac in the MTL700 range.
04How does it differ from the MTL7761ac?
The MTL7761ac has a 9 V, 90 ohm, 100 mA description and 107 ohm end-to-end resistance with a 100 mA fuse; the MTL7761Pac trades that for 350 ohm, 26 mA and 378 ohm.
05What role does the MTL7761Pac play in a double bridge circuit?
The datasheet uses two MTL7761Pac barriers as the sense and pick-off interfaces, while an MTL7766Pac supplies the bridge power in a circuit safe for IIC.