- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: MTL (Eaton)
MTL SDPSTN Telephone Line Surge Protector
Description
Telephone lines are antennas: SDPSTN
A long overhead or buried telephone pair picks up lightning-induced surges, and the modem or telemetry unit at the end of it is the part that fails. The MTL SDPSTN is the SD-range module made for public switched telephone network circuits. It is rated 162 V dc or 114 V ac nominal, passes 550 mA, adds 4.7 ohm per line and keeps a 4 MHz bandwidth, so voice-band modem signals and data tones pass through unchanged.
SDPSTN data table
| Model | SDPSTN |
|---|---|
| Application | public switched telephone network lines |
| Nominal voltage | 162 V dc / 114 V ac |
| Nominal current | 550 mA |
| Series resistance | 4.7 ohm per line |
| Maximum leakage current | 5 microamps |
| Rated voltage MCOV | 175 V |
| Protection level at 1 kV per microsecond | below 200 V |
| Residual voltage at isn | 235 V |
| Bandwidth | 4 MHz |
| Maximum surge current | 20 kA (8/20 microseconds) |
| Nominal discharge current | 3 kA |
| Response time | below 1 ns |
| Category tested | A2, B2, C1, C2, C3 |
| Standards | EN 61643-21 (IEC), EN 41003 (SDPSTN) |
| Weight | about 70 g |
Telemetry applications for SDPSTN in the Gulf
Remote outstations on pipelines, water networks and electricity substations frequently use dial-up or leased PSTN lines as a back-up or primary path. Wells, booster stations and tank-level sites in sparsely populated areas often rely on such links. The SDPSTN sits where the telephone line enters the cabinet, ahead of the modem, so that a surge on the line is clamped before it reaches electronic equipment.
The datasheet highlights telemetry outstations as the application and lists compliance with EN 41003 for telecom equipment connected to public networks.
Differences from other SD modules
SDPSTN differs from the signal-loop devices in the way voltage is set. Loop modules clamp at 7 to 55 V. The PSTN line carries ringing voltage and dc battery that can reach well above that, so the SDPSTN rated voltage is 175 V with a protection level below 200 V. Its 4 MHz bandwidth is higher than the 25 kHz of standard SD types but lower than the 50 MHz R types, matching the modem tones it must pass. The series resistance of 4.7 ohm is modest relative to the loop resistance of a telephone pair.
Fitting the SDPSTN
Clip the module to the rail, connect the incoming line to the field terminals and the modem to the protected terminals, and make sure the rail has a short, solid connection to the earth bar. Do not route unprotected line wiring past the protected side. The datasheet’s guidance on single-point earthing applies strongly here, because telephone lines are long and exposed.
Mount the module in the same cabinet or very close to the equipment it protects.
Care of SDPSTN
Test the line for noise and dial-up reliability after installation. A surge-stressed module may show raised leakage and degraded line quality. Keep a spare for sites that depend on a single line. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What the SDPSTN figures mean for a telemetry link
The SDPSTN’s nominal rating of 162 V dc and 114 V ac sets the line voltage it can carry in service, and its rated voltage of 175 V is the level at which clamping begins. Series resistance of 4.7 ohm per line is small beside the loop resistance of a typical telephone pair, so the added signal loss is small.
On the protection side, a voltage level below 200 V at 1 kV per microsecond is a level many line modems and line-interface chips can withstand repeatedly, while the 235 V residual voltage under a 3 kA surge shows what remains after clamping. Together with the 20 kA maximum surge rating, the module gives margin for outstation conditions.
Leakage of 5 microamps will not load the line, and the 4 MHz bandwidth is plenty for voice-band modem signals up to the speed of typical dial-up telemetry.
Standards and test categories noted for SDPSTN
The datasheet lists compliance with EN 61643-21 for surge protection devices, EN 61326-1 and EN 41003 for emissions and telecom connection, and EN 60950-1 for safety of information technology equipment, with category tests A2, B2, C1, C2 and C3. The surge ratings are 20 kA at 8/20 microseconds, with a nominal discharge current of 3 kA and a lightning impulse current of 2.8 kA at 10/350 microseconds, and the response time is under 1 ns. Weight is about 70 g and terminals take 2.5 mm2 conductors.
Typical outstation layout places the SDPSTN at the point where the telephone pair enters the cabinet, with a separate SD07R or SD32R on any RS485 or RS232 port inside, and a TP48 or SD32X on the field transmitters. The same SD family therefore covers the line, the data ports and the sensors, which lowers the variety of spares to stock.
Record the line identity, the installation date and the earth bonding test result on the maintenance sheet. After a thunderstorm season, compare modem error counts with the previous season; a surge-damaged protector often shows as a rise in retransmissions even when the line still works.
Typical lifetime is long because there is no moving part, yet the sensible interval for replacing a protector in a high-lightning region is after any event that damages other equipment on the same cable route, since the protector may have absorbed the largest share of the energy.
Label the cabinet entry point clearly for line technicians.
Documents and quotation
See the SD range datasheet for accessories and approvals. Send an RFQ for SDPSTN with quantity and delivery location in Oman or the GCC.
Selection Notes for the MTL SDPSTN
When comparing the MTL SDPSTN with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the MTL (Eaton) isolator & barrier range and confirm the correct order code before you commit.
Other Models in the MTL SD Surge Range
Seven Star LLC supplies models from the MTL SD Surge range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| MTL SD07R3 Low-Voltage 3-Terminal Surge Protector | Isolator & Barrier | View details |
| MTL SD32T3 Three-Terminal Surge Protection Device | Isolator & Barrier | View details |
| MTL SD275X 240 V AC High-Current Surge Protector | Isolator & Barrier | View details |
| MTL SDPSTN Telephone Line Surge Protector | Isolator & Barrier | You are viewing this model |
| MTL SDRTD 3-Wire RTD Surge Protection Device | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet MTL SDPSTN Telephone Line Surge Protector Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.
Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.
MTL (Eaton) company profile
| Founded | 1971, Luton, England, as Measurement Technology Ltd |
|---|---|
| Origin | Spin-off from Kent Instrumentation |
| Headquarters | Luton, England |
| Ownership | Eaton (Crouse-Hinds), via Cooper Industries from 2008 |
| Product families | MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points |
Milestones
- 1971: Measurement Technology Ltd is founded in Luton.
- 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
- 2008: Cooper Industries acquires MTL Instruments for £144 million.
- 2012: Eaton acquires Cooper Industries.
MTL product families listed here
Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.
Where MTL barriers and isolators are used
These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.
MTL (Eaton) products we list
Ordering MTL modules: what we need
Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.
Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.
Browse MTL (Eaton) products by category: Isolator & Barrier, Automation Software.
FAQ
Questions about the MTL SDPSTN Telephone Line Surge Protector
Answers from our engineering team on installation, compatibility and integration.
01What is the SDPSTN used for?
Protecting signals on public switched telephone networks, for example the dial-up line to a telemetry outstation.
02What voltage does the SDPSTN handle?
Nominal 162 V dc or 114 V ac, with a rated MCOV of 175 V, a protection level below 200 V at 1 kV per microsecond and a residual voltage of 235 V.
03What bandwidth and series resistance does it have?
4 MHz bandwidth and 4.7 ohm series resistance per line, with 550 mA nominal current and 5 microamp leakage.
04Does it need an earth connection?
Like the other SD modules it clips onto DIN rail, which makes the earth connection automatically, so a good rail-to-ground bond is essential.
05Is it an intrinsically safe device?
The ATEX Ex ia listing in the datasheet does not include the SDPSTN. Use it in the safe area or in line with the manufacturer's non-incendive guidance.


















Reviews
There are no reviews yet.