Brand:

Pepperl+Fuchs NBB5-18GM50-E2 M18 PNP Inductive Sensor 5 mm

Description

Pepperl+Fuchs NBB5-18GM50-E2: the rugged 3-wire PNP proximity switch

The Pepperl+Fuchs NBB5-18GM50-E2 is a DC three-wire inductive sensor with a PNP normally open output and a 5 mm flush rated operating distance. It sits in a brass body with white bronze coating, threaded M18 x 1, 56 mm long and 18 mm in diameter, with a green PBT sensing face and a black 2 m PVC cable.

Pepperl+Fuchs promotes this version for harsh environments. The datasheet lists an extended ambient range of -40 to 85 degrees C, an extended operating voltage range of 6 to 36 V, high shock resistance and a switching frequency of up to 1950 Hz. Protection is stated as IP65 / IP66 / IP67 / IP68 / IP69, so the sensor tolerates high-pressure washdown, and PWIS conformity is given as VDMA 24364-C1/T100°C-W.

NBB5-18GM50-E2 data table

Parameter Value
Part number NBB5-18GM50-E2
Switching function Normally open (NO)
Output PNP, 3-wire, DC
Rated operating distance 5 mm flush
Assured operating distance 0 to 4.05 mm
Actuating element mild steel, 18 mm x 18 mm x 1 mm
Reduction factors rAl 0.35, rCu 0.29, r304 0.73, rBrass 0.44
Operating voltage 6 to 36 V
Switching frequency 0 to 1950 Hz
Hysteresis typically 5 percent
Voltage drop 1 V or less
Operating current 0 to 200 mA
Off-state current 20 microamps maximum
No-load supply current 10 mA or less
Time delay before availability 10 ms or less
Short-circuit protection pulsing
MTTFd 1610 a, TM 20 a, DC 0 percent
Ambient temperature -40 to 85 degrees C
Housing / face Brass, white bronze coated / PBT green
Protection IP65 to IP69
Cable 2 m PVC black, 4.3 mm, 3 cores, 0.34 mm2
Mass / size 112 g, 56 mm x 18 mm
Tightening torque 30 Nm or less

Industrial uses for the NBB5-18GM50-E2

A brass PNP sensor with a wide voltage window is the workhorse behind PLC inputs throughout process plants. In oil and gas facilities away from hazardous zones it checks pump coupling guards, motor starters, valve actuator indicator shafts and skid door interlocks. In water and wastewater works it reports screw-conveyor movement and clarifier bridge position, while packaging and manufacturing lines use it for counting and part presence.

The extended temperature range down to -40 degrees C and up to 85 degrees C suits equipment that stands in the Gulf sun but is also shipped through cold-chain locations, and the IP69 rating handles hose-down cleaning in food and beverage plants in Oman.

How NBB5-18GM50-E2 differs from other NBB sensors

Within the NBB5 M18 line the options include a connector plug (NBB5-18GM50-E2-V1), a weld-immune ceramic variant (NBB5-18GM50-E2-C3-V1) and longer-cable versions. Compared with the weld-immune NBB5-18GM50-E2-C3-V1, this sensor accepts 6 to 36 V rather than 10 to 30 V, switches at 1950 Hz rather than 800 Hz, and has a voltage drop of 1 V or less instead of 3 V or less.

Compared with the larger NBB15-30GM50-E2-V1-M it has a 5 mm instead of 15 mm range and a lower 36 V maximum supply, because the M30 unit goes up to 60 V.

Selection notes

A PNP output sources current to the load and is common on European and Gulf-region PLC input cards. If your input card expects an NPN sensor, select a different variant. The 200 mA load capability is enough for a PLC input or a small relay, but not for a contactor coil. Reduction factors matter: brass targets are sensed at 44 percent and stainless steel 304 at 73 percent of the rated distance.

Protection class II, rated insulation voltage 36 V and rated impulse withstand voltage of 500 V are given on the datasheet, together with cULus listing and DNV marine approval TAA00003AK.

Installing the NBB5-18GM50-E2 and putting it into service

Fit the barrel with the supplied nuts and tighten to no more than 30 Nm. Because this sensor is a flush type, surrounding metal may reach the sensing face, so it can be sunk into a steel bracket. Connect brown to positive, blue to negative and black to the PLC input, assuming the standard EN 60947-5-2 colours, and confirm the yellow LED lights when the target is within range.

Do not exceed 36 V. Ensure the cable is routed with a bending radius of more than 10 times its 4.3 mm diameter.

Maintenance

The sensor is maintenance free apart from a periodic check of the sensing face and fixing. Clean metallic chips from the face. A sensor that does not switch can be tested with a mild steel target and a multimeter on the output.

Electrical behaviour worth knowing before wiring the NBB5-18GM50-E2

The off-state current is at most 20 microamps, so a PLC input with a high impedance will not be falsely held on by leakage. The no-load supply current of up to 10 mA and the 10 ms delay before availability after power-up are useful for planning start-up sequences: a controller should ignore the input for at least that long after energising. Short-circuit protection is of the pulsing type, which means that if the output is shorted the sensor repeatedly retries rather than latching off, and it recovers by itself once the fault is removed.

Reverse polarity protection is built in, so swapping brown and blue on a first installation will not destroy the electronics, although the sensor will not operate until the wires are corrected. The mission time of 20 years and MTTFd of 1610 years are the safety-relevant values given, with diagnostic coverage of 0 percent, which matters if the sensor is used in a safety function evaluated to EN ISO 13849.

Ordering notes

State NBB5-18GM50-E2 in full when you send the RFQ with quantity and delivery place. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Documents and quotation

The datasheet for the NBB5-18GM50-E2 is available on request and attached to this listing. Please send an RFQ with part number NBB5-18GM50-E2 and quantity.

Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs NBB5-18GM50-E2 M18 PNP Inductive Sensor 5 mm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs NBB5-18GM50-E2 M18 PNP Inductive

Answers from our engineering team on installation, compatibility and integration.

01What output does the NBB5-18GM50-E2 have?
A PNP normally open DC output on three wires, switching up to 200 mA with a voltage drop of 1 V or less.
02What supply voltage and speed does it allow?
6 to 36 V supply and a switching frequency of 0 to 1950 Hz.
03What are its environmental ratings?
Ambient range of -40 to 85 degrees C and protection of IP65 / IP66 / IP67 / IP68 / IP69, in a brass white bronze coated housing.
04How long is the cable and what are its cores?
A 2 m black PVC cable of 4.3 mm diameter with three cores of 0.34 mm2.
05How can I get a quote in the GCC?
Send an RFQ to Seven Star LLC quoting NBB5-18GM50-E2 and quantity.