- Automation & ControlView all 2,937 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Beamex
Beamex 9010260 PGHH Hydraulic Calibration Pump 700 bar
Description
Beamex 9010260 PGHH hydraulic pump to 700 bar
Beamex 9010260 is the complete PGHH, a hand-operated hydraulic calibration pump covering 0 to 700 bar (0 to 10,000 psi). Hydraulic pumps exist because air is a poor medium at very high pressure: gas stores energy, drifts thermally and is hazardous when a hose lets go. With the 9010260 the circuit is filled with low viscosity mineral hydraulic oil or distilled water, so the pressure builds with a small stroke and sits steady.
The pump comes as a kit with hose, fittings, seals, filling bottle and a hard case, and it stands upright on a bench or on a calibration stand. At 1.3 kg and 265 x 160 x 120 mm it is much lighter than a lever-operated bench pump.
Parts of the 9010260 you will touch every day
Controls:
- Pump handles squeezed by hand, with a Prime/High stroke selector: leave it in prime (fully out) until squeezing becomes heavy, then select high pressure and use shorter strokes.
- Fine adjust, an adjustable volume that trims pressure; also the main tool for releasing pressure from the system.
- Vent valve, turned counterclockwise to release; the manual warns never to unscrew it completely because the release valve tappet inside may fall out.
Ports and reservoir:
- Side port: G1/4 inch female with Bx 1215 male fitting for the Beamex 630 bar hose.
- Top port: G1/4 inch B female for an EXT60 to EXT1000 module, supplied blanked with a PGHH G1/4 inch male pressure plug.
- Acrylic reservoir of 200 ml (12.2 cubic inches), which is never pressurized, with a filling plug and a bottom drain screw.
9010260 data table
| Parameter | Value |
|---|---|
| Order code | 9010260 (complete) |
| Pressure range | 0 to 700 bar (0 to 10,000 psi) |
| Media | Low viscosity mineral hydraulic oil (RENOLIN MR 5 VG 22) or distilled water |
| Weight | 1.3 kg (2.87 lb) |
| Height x width x depth | 265 x 160 x 120 mm |
| Reservoir | 200 ml acrylic, not pressurized |
| Operating temperature | 0 to 50 degrees C |
| Storage temperature | -10 to 50 degrees C |
| Kit hose | 630 bar, 1 m, ID 2 mm, OD 5 mm, bursting 2000 bar, Bx 1215 female ends, -35 to 100 degrees C |
| Max fitting torque | 15 Nm (anodized aluminium body) |
What the 9010260 kit contains
The delivery lists the pump, a 630 bar pressure hose of 1.0 m (code 7021390), a Bx 1215 male to 1/4 inch NPT male fitting for connecting the hose to the device under test, bonded seals for EXT and PGHH, copper gaskets for G1/4 inch B fittings, a filling bottle with cap, the user manual and the hard case. The manual recommends bonded seals up to 600 bar and copper gaskets above 600 bar when an EXT module is mounted on the top port.
Priming and running the 9010260
Fill the reservoir to at least two thirds and at most three quarters, close the plug, set fine adjust fully clockwise and close the vent valve. Squeeze until drops of liquid appear at the loose hose end, then attach the instrument. The measurement system must contain liquid only, with the total volume kept under 200 ml; the pump interior is less than 1 ml and the hose adds 3.5 ml per meter. Purge by raising pressure to about 50 bar, venting, and repeating two or three times, then work up to 100 to 150 bar and open the fine adjust slowly. Keep the pump upright throughout so air can move through the pressure compensation screw, otherwise the reservoir may break. After pressure changes wait two to five minutes and re-trim.
Why choose 9010260 rather than the other Beamex pumps
The 9010260 matches applications that need 40 to 700 bar with oil or water compatible with the device under test. For air up to 140 bar use the PGPH (9010180); the PGHS reaches 1000 bar with a larger frame. Remember also that the PGHH relies on the Bx 1215 630 bar thread family, not the Bx G1/8 40 bar family used by PGC and PGL pumps, so hoses are not interchangeable between them.
Maintenance of the 9010260
Cleaning, fluid level and fluid quality are the key routines. Change the fluid as soon as it turns cloudy or shows particles. Wipe the reservoir only with a lint-free wet cloth and never use chemicals; flush with distilled water or the recommended oil if needed. When used with distilled water, empty the reservoir and let the pump dry after every use. Check the pressure compensation screw by removing it and blowing compressed air through it from below. A leak test at 700 bar allows the pressure to decay by less than 5 bar in the two minutes after a five-minute settling and re-trim. Spare parts are listed in the Beamex web shop, for example the full service kit 0500400.
Applications for the 9010260 in Oman and the GCC
Typical uses are calibration of high-range pressure transmitters and gauges on injection skids, wellhead and pipeline test points, compressor discharge instruments and hydraulic test circuits in refinery workshops, as well as laboratory work in universities and quality departments. The transparent reservoir lets technicians watch fluid quality at a glance, which matters because the manual asks you to change the fluid at the first cloudiness, particles or dirt. Because the pump is compact, one technician can carry it, its hose and its case to a skid or a platform without a trolley. A connected EXT module on the top port gives a reference reading right at the pump.
Documents and quotation
The PGHH user manual covers the unpacking list, specifications, overview figures and the operating sequence used here. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send your RFQ with Beamex 9010260, quantity and, if relevant, whether you also need an EXT module, the 0500400 service kit or additional hoses.
Other Models in the Beamex Pg Pump Range
Seven Star LLC supplies models from the Beamex Pg Pump range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 9010180 PGPH Pneumatic Calibration Pump 140 bar | Process, Pressure & Temperature Calibrators | View details |
| Beamex 9010050 PGC Calibration Pump Complete Kit 35 bar | Process, Pressure & Temperature Calibrators | View details |
| Beamex 9010260 PGHH Hydraulic Calibration Pump 700 bar | Process, Pressure & Temperature Calibrators | You are viewing this model |
Datasheets & Documents
- Datasheet Beamex 9010260 PGHH Hydraulic Calibration Pump 700 bar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9010260 PGHH Hydraulic Calibration Pump 700
Answers from our engineering team on installation, compatibility and integration.
01Which pressure range does Beamex 9010260 cover?
The PGHH covers 0 to 700 bar (0 to 10,000 psi) using hydraulic oil or distilled water as the pressure medium.
02What fluids are allowed in the 9010260?
Low viscosity mineral hydraulic oil (RENOLIN MR 5 VG 22) or distilled water; synthetic hydraulic oil may damage the seals and the reservoir.
03Does the 9010260 include a hose?
Yes, a 630 bar hose of 1.0 m with Bx 1215 ends, plus a Bx 1215 male to 1/4 inch NPT male fitting, and a hard case.
04How large can the connected system be?
The maximum total volume of the measurement system must not exceed 200 ml, the capacity of the reservoir.
05Can an EXT module sit on top of the 9010260?
Yes, the top G1/4 inch B port accepts an EXT60 to EXT1000 module; use a bonded seal below 600 bar and a copper gasket above it.


















Reviews
There are no reviews yet.