Description

Michell XPM601-EX-BGA overview: hazardous-area paramagnetic oxygen analyzer for oxygen in hydrogen

Michell XPM601-EX-BGA is the ordering example of the XPM601, a hazardous-area paramagnetic analyzer for monitoring oxygen in hydrogen produced by electrolysis. It is certified by ATEX, UKCA, IECEx and cQPSus and measures 0 to 5 percent oxygen in hydrogen.

This page repeats the facts published by the manufacturer for Michell XPM601-EX-BGA so that engineers, maintenance planners and buyers can confirm the code before sending an enquiry. The photograph shows the Michell product line that the XPM601-EX-BGA code belongs to, taken from the manufacturer product page.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list XPM601-EX-BGA so that procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of XPM601-EX-BGA

  • Range 0 to 5 percent O2 in H2
  • Accuracy better than ±0.1 percent O2
  • Through-glass display
  • Two 4 to 20 mA outputs and Modbus RTU RS485
  • SIL 2 capable version available
  • ATEX, IECEx, UKCA and cQPSus certified

XPM601-EX-BGA technical specifications

Parameter Value
Order code XPM601-EX-BGA
Technology Paramagnetic
Range Up to 5 percent O2
Accuracy Less than ±0.1 percent O2
Repeatability Less than ±0.012 percent O2
Sample flow 100 ml/min
Sample pressure 0.33 barg
Power 24 V DC, 1.5 A max
Outputs 2 x 4 to 20 mA; Modbus RTU RS485; 2 relays
Gas connection 1/8 inch NPT female
Ingress protection IP66 / NEMA 4X
Warm-up time Less than 25 minutes

Values above are taken from the manufacturer datasheet and order-code sheet listed on this page. The manufacturer states that specifications can change as part of continuous development, so confirm the current revision when the XPM601-EX-BGA is part of a tender or a certified installation.

Typical applications of XPM601-EX-BGA in Oman and the GCC

Safe operation of electrolyzers and hydrogen purity determination.

  • Oil and gas: gas processing plants, wellsites, export pipelines and metering stations
  • Utilities and power: turbine fuel gas, instrument air and compressed air systems
  • Water and desalination: process air, gas generation and laboratory support
  • Manufacturing and laboratories: calibration, electronics, pharmaceutical and industrial gas production

Dew point is the temperature at which water vapour in a gas begins to condense at a given pressure, so a lower dew point means drier gas. Pressure dew point is the value at line pressure and is the figure that matters for compressed air and process gas, while atmospheric dew point refers to the same gas expanded to ambient pressure and reads much lower. Moisture can also be expressed in ppmV, a pressure-corrected volume fraction, so always confirm the unit and the reference pressure on a specification.

Good sample handling decides the quality of any moisture or dew-point reading. Use stainless steel tubing, keep lines short, avoid dead legs and filter out particles and liquids before the sensor. Plastic or rubber tubing absorbs and releases water vapour and slows the response, particularly at low dew points, and ambient moisture can enter through poorly made fittings, so check for leaks after commissioning.

Selection and compatibility notes for XPM601-EX-BGA

Letters: EX certification, B range 0 to 5 percent, G hydrogen background, A no SIL or B SIL 2.

Many Michell codes are built from a parent code followed by option letters. When you ask for a quotation for XPM601-EX-BGA, copy the complete code from the instrument label or from your purchase specification, including every letter after the parent code, and state the serial number if the unit replaces an installed one.

Before ordering, collect the data that avoids mistakes: the complete code and option letters, the serial number and year of any installed unit, the supply voltage, the hazardous-area certificate required by the site, the process pressure and temperature, the gas composition and the connection type. For spares from older installations, a photograph of the nameplate helps confirm the match, and it is useful to say whether the item replaces a failed device or is for a new installation.

Ask for the calibration certificate type your quality system needs, such as a traceable factory certificate or an accredited laboratory certificate where the manufacturer offers it, and keep it with the asset record so the next calibration date is visible during audits.

Installation and commissioning of XPM601-EX-BGA

Wall-mount, connect 24 V DC and gas.

Always read the current manufacturer manual before commissioning, check the hazardous-area certificate where one applies, verify the supply and signal wiring, and record the as-found settings so that the next service visit has a reference.

Gulf installations add heat, dust and humidity. Instruments mounted outdoors need shade or a suitable enclosure, cable glands that match the enclosure rating and sample lines that avoid condensation on cold desert nights. Compare the ambient temperature range in the table with the highest site temperature before choosing a mounting position.

Maintenance and calibration of XPM601-EX-BGA

Calibration without hot works permit using the through-glass display.

Moisture and dew-point measurements drift only slowly when the sample is clean, so most problems seen on installations of this kind come from contaminated sample lines, leaking fittings, wrong flow or damaged cables rather than from the instrument itself. A planned calibration interval agreed with your quality system keeps the measurement traceable.

Related products and ordering notes for XPM601-EX-BGA

The same manufacturer family includes sensors, transmitters, online hygrometers, chilled-mirror reference instruments, hydrocarbon dew-point analyzers, sampling systems and calibration equipment. Other Michell codes already listed on this site, such as the Easidew transmitters, the Promet EExd analyzer and the Condumax II, can be quoted together in a single RFQ.

XPM601-EX-BGA FAQ summary

Typical questions concern what the code means, which options apply and what to send with an enquiry. In short, it is a hazardous-area paramagnetic oxygen analyzer for oxygen in hydrogen, and the figures in the table above come from the manufacturer documents. Questions that are not answered here can be sent with the RFQ.

Documents and quotation

The manufacturer datasheet for XPM601-EX-BGA is attached to this page where available. To request a quotation, send an RFQ with the part number XPM601-EX-BGA, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.

Datasheets & Documents
  • PDF Datasheet Michell XPM601-EX-BGA Paramagnetic Oxygen Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell XPM601-EX-BGA Paramagnetic Oxygen Analyzer

Answers from our engineering team on installation, compatibility and integration.

01What is XPM601-EX-BGA?
XPM601-EX-BGA is a hazardous-area paramagnetic oxygen analyzer for oxygen in hydrogen, as described in the manufacturer datasheet and order-code sheet.
02What does XPM601-EX-BGA measure?
Oxygen up to 5 percent in hydrogen. See the manufacturer datasheet for details.
03Power for XPM601?
24 V DC. See the manufacturer datasheet for details.
04Can Seven Star LLC supply XPM601-EX-BGA in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for XPM601-EX-BGA?
Send the part number XPM601-EX-BGA, the quantity, the full option string or instrument serial number, any certificate needs and the delivery location so we can prepare an accurate quotation.