IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] DIN I/P Transmitter

Description

Moore Industries IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] overview

The Moore Industries IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] is a high-performance current-to-pressure transmitter that lets a DCS, PLC or PC control a pneumatic actuator, valve or damper drive. It converts 4-20 mA to a proportional 3-15 psig output and is made in a compact 40 mm wide aluminum housing that snaps onto a standard rail or a Moore Industries pneumatic header rack such as the RIR and SIR.

A front-panel LED varies in intensity with input current strength and a built-in orifice cleaning mechanism is provided, according to the datasheet.

The part number IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, supply pressure, option and housing (Unit / Input / Output / Supply Pressure / Option [Housing]). The string written as IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.

  • IPT2: DIN-style current-to-pressure transmitter
  • 4-20MA: input signal into 375 ohms maximum
  • 3-15PSIG: pneumatic output range
  • 20PSI: supply pressure
  • -FA1: access designation required for this housing
  • [DIN]: aluminum DIN-style housing assembly

Key features of the Moore Industries IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]

  • Choice of 18 standard output ranges and several air supply options.
  • Compact 40 mm aluminum housing for rail or rack.
  • LED that varies with input current.
  • Built-in orifice cleaning mechanism.
  • Meets SAMA PMC 31.3 for shock and vibration.

Technical specifications for IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]

Parameter Value
Model string IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]
Input 4-20 mA into 375 ohms maximum
Output 3-15 psig
Supply Instrument air, 20-40 psig, 5 psig above maximum output
Accuracy Less than plus or minus 0.25% of span
Step response Less than 0.2 seconds into 100 ml load
Air consumption 0.08 SCFM typical
Air capacity 2.0 SCFM minimum
Voltage drop 7.5 V maximum (5 V without LED)
Shock and vibration effect 0.25%/G or better over 5-15 Hz
Operating and storage temperature -40 to +80 degrees C
Temperature effect Less than plus or minus 0.025% of span per degree C, 0 to 50 degrees C
Adjustments Zero and span screws, plus or minus 10% minimum

The values above come from the manufacturer datasheet for the IPT2 family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.

Typical applications of the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] in Oman and the GCC

Used where many I/P converters are grouped in a marshalling cabinet or on a pneumatic header rack.

In oil and gas, petrochemical, power and water plants, current-to-pressure transmitters like the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] turn the 4-20 mA output of a DCS or PLC into a pneumatic signal that drives control valve actuators, dampers and other pneumatic devices.

They are often used where a pneumatic valve does not have its own positioner, on retrofit projects, on louvres and dampers in ventilation and boiler systems, and on process skids where an I/P with a simple loop-powered connection is preferred.

With high ambient temperatures and dust in Oman and the GCC, a rugged housing and a clean air supply are important to keep the unit running reliably.

Selection and compatibility notes for IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]

The access designation (-FA1 here) is a required selection; Table 2 of the datasheet describes the options.

Confirm the input range, the pneumatic output range and the supply pressure shown in the model string. The supply pressure must exceed the highest output pressure by the margin stated in the datasheet.

Check the air quality. The datasheet requires instrument air, and filtering and regulation upstream (optionally with the filter and regulator option) protect the orifice and nozzle from dirt and moisture.

Check the housing and mounting arrangement against the site: pipe, wall or rail mounting, indoor or outdoor, and the certification needed for the area.

Installation and commissioning

Mount the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] in a position with minimal vibration. Connect the supply air through a filter and regulator and use tubing sized for the air capacity needed by the actuator.

Wire the current loop with the correct polarity and check that the DCS output card can drive the voltage drop of the unit plus the loop resistance.

Apply supply air, stroke the loop through 4, 12 and 20 mA, and use the zero and span adjustments to set the pneumatic output to the stated range. Check for air leaks at each fitting with a leak detection fluid.

Maintenance and spares

Drain and replace filter elements regularly, since contamination is the most common cause of I/P drift. Check supply pressure, inspect tubing and fittings for leaks, and recheck zero and span at your scheduled calibration interval.

The datasheet describes an orifice-cleaning feature on some models; use it as the manual describes rather than disassembling the unit in the field.

Related products and ordering notes

The SIR and RIR racks mount a row of IPT2 units.

Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Frequently asked questions about IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]

  • What does the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] do? It converts 4-20 mA into a 3-15 psig pneumatic signal.
  • How wide is the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]? The datasheet describes a compact housing 40 mm wide.
  • What supply air does the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] need? It needs instrument air only, at a supply pressure of 20-40 psig per the datasheet.
  • What is the accuracy of the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]? The datasheet states accuracy of less than plus or minus 0.25% of span, including linearity and hysteresis.
  • How do I order the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the IPT2 family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.

To request a quotation, send an RFQ that includes the part number IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.

Datasheets & Documents
  • PDF Datasheet IPT2 DIN-Style Current-to-Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] DIN I/P

Answers from our engineering team on installation, compatibility and integration.

01What does the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] do?
It converts 4-20 mA into a 3-15 psig pneumatic signal.
02How wide is the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]?
The datasheet describes a compact housing 40 mm wide.
03What supply air does the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN] need?
It needs instrument air only, at a supply pressure of 20-40 psig per the datasheet.
04What is the accuracy of the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]?
The datasheet states accuracy of less than plus or minus 0.25% of span, including linearity and hysteresis.
05How do I order the IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.