IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] I/P Transmitter

Description

Moore IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] overview

The Moore IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] is a two-wire, loop-powered current-to-pressure (I/P) transmitter from Moore Industries. It converts a 4-20 mA signal from a DCS, PLC or PC-based system to a proportional 3-15 psig pneumatic signal to control valves, actuators and other pneumatic devices.

The -FR1 option mounts a coalescing filter, miniature supply regulator and a gauge reading 0-60 psig and 0-4 bar on the unit, and the WDNA housing is an aluminum body with aluminum cover. The IPH2 is described as watertight, dust-protected and resistant to corrosion and chemicals.

The part number IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, supply pressure, options and housing (Unit / Input / Output / Supply Pressure / Options [Housing]). The string written as IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.

  • IPH2: Type 4X current-to-pressure transmitter
  • 4-20MA: input signal into 250 ohms maximum
  • 3-15PSIG: pneumatic output range
  • 20PSI: supply pressure
  • -FR1: coalescing filter, miniature supply line regulator and pressure gauge
  • [WDNA]: aluminum body with aluminum cover, NPT pneumatic and electrical entry ports

Key features of the Moore Industries IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]

  • Accepts 4-20 mA, 4-12 mA or 12-20 mA input into 250 ohms maximum.
  • Accuracy of less than plus or minus 0.25% of span.
  • Step response under 0.25 seconds into a 100 ml load.
  • Air capacity of 5.0 SCFM minimum.
  • Mounts in any position with negligible position effect.
  • Optional coalescing filter and regulator with gauge.

Technical specifications for IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]

Parameter Value
Model string Moore IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]
Input 4-20 mA into 250 ohms maximum
Output 3-15 psig
Supply pressure 20 psig (instrument air, 20-35 psig; at least 5 psig above maximum output)
Accuracy Less than plus or minus 0.25% of span (including linearity, hysteresis, repeatability)
Step response Less than 0.25 seconds into 100 ml (6 cubic inch) load, 10% to 90%
Supply pressure effect Negligible from 20-35 psig, steady pressure
Air capacity 5.0 SCFM minimum (20 psig supply, 0 psig output)
Relief capacity 2.5 SCFM minimum (15 psig output)
Voltage drop 5 V maximum
Air consumption (dead-ended) 3.9 SCFH average at 3-15 psig output and 20 psig supply

The values above come from the manufacturer datasheet for the IPH2 family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.

Typical applications of the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] in Oman and the GCC

It is used on pneumatic control valves, dampers and similar devices that lack a positioner, including retrofit work.

In oil and gas, petrochemical, power and water plants, current-to-pressure transmitters like the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] turn the 4-20 mA output of a DCS or PLC into a pneumatic signal that drives control valve actuators, dampers and other pneumatic devices.

They are often used where a pneumatic valve does not have its own positioner, on retrofit projects, on louvres and dampers in ventilation and boiler systems, and on process skids where an I/P with a simple loop-powered connection is preferred.

With high ambient temperatures and dust in Oman and the GCC, a rugged housing and a clean air supply are important to keep the unit running reliably.

Selection and compatibility notes for IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]

The datasheet states that -FR1 and -GA1 are not compatible with the natural gas (-NG) options. Supply must be instrument air.

Confirm the input range, the pneumatic output range and the supply pressure shown in the model string. The supply pressure must exceed the highest output pressure by the margin stated in the datasheet.

Check the air quality. The datasheet requires instrument air, and filtering and regulation upstream (optionally with the filter and regulator option) protect the orifice and nozzle from dirt and moisture.

Check the housing and mounting arrangement against the site: pipe, wall or rail mounting, indoor or outdoor, and the certification needed for the area.

Installation and commissioning

Mount the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] in a position with minimal vibration. Connect the supply air through a filter and regulator and use tubing sized for the air capacity needed by the actuator.

Wire the current loop with the correct polarity and check that the DCS output card can drive the voltage drop of the unit plus the loop resistance.

Apply supply air, stroke the loop through 4, 12 and 20 mA, and use the zero and span adjustments to set the pneumatic output to the stated range. Check for air leaks at each fitting with a leak detection fluid.

Maintenance and spares

Drain and replace filter elements regularly, since contamination is the most common cause of I/P drift. Check supply pressure, inspect tubing and fittings for leaks, and recheck zero and span at your scheduled calibration interval.

The datasheet describes an orifice-cleaning feature on some models; use it as the manual describes rather than disassembling the unit in the field.

Related products and ordering notes

The IPX2 is the explosion-proof variant of this family; the IPT2 is a DIN-style I/P transmitter.

Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Frequently asked questions about IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]

  • What does the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] do? It converts a 4-20 mA signal to a proportional 3-15 psig pneumatic output.
  • What air supply does the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] need? Instrument air at 20-35 psig, which must be at least 5 psig above the maximum output.
  • What does -FR1 mean on the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]? It adds a coalescing filter, miniature supply regulator and a gauge reading 0-60 psig and 0-4 bar.
  • How accurate is the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]? The datasheet states less than plus or minus 0.25% of span.
  • How do I order the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the IPH2 family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.

To request a quotation, send an RFQ that includes the part number IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.

Datasheets & Documents
  • PDF Datasheet IPH2 Type 4X Current-to-Pressure Transmitter with Filter Regulator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] I/P

Answers from our engineering team on installation, compatibility and integration.

01What does the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] do?
It converts a 4-20 mA signal to a proportional 3-15 psig pneumatic output.
02What air supply does the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA] need?
Instrument air at 20-35 psig, which must be at least 5 psig above the maximum output.
03What does -FR1 mean on the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]?
It adds a coalescing filter, miniature supply regulator and a gauge reading 0-60 psig and 0-4 bar.
04How accurate is the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]?
The datasheet states less than plus or minus 0.25% of span.
05How do I order the IPH2/4-20MA/3-15PSIG/20PSI/-FR1 [WDNA]?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.