Brand:

Pepperl+Fuchs KFA6-STR-1.24.4 Power Supply 24 V DC 4 A

Description

Pepperl+Fuchs KFA6-STR-1.24.4 overview

The Pepperl+Fuchs KFA6-STR-1.24.4 is a regulated power supply from the K-System of Pepperl+Fuchs that provides 24 V DC at 4 A from a mains supply of 92 to 265 V AC. It has removable terminals, LED fault indication and mounts directly on the Power Rail, from which it can supply K-System isolated barriers.

The datasheet released on 14 February 2023 describes a replaceable fuse and LED: green indicates normal operation and a flashing red indicates a fault. The output is limited by a 4 A slow-blow fuse on the Power Rail, with electronic limitation typically at 4.6 A, and the efficiency is typically 87 percent.

Key features of the Pepperl+Fuchs KFA6-STR-1.24.4

  • Regulated 24 V DC output with up to 4 A output current
  • Input 92 to 265 V AC, 47 to 63 Hz
  • Fused output with replaceable fuse
  • LED indication: green normal, flashing red fault
  • Suitable for Power Rail supply
  • Efficiency typically 87 percent, ripple below 100 mV peak-to-peak
  • Ambient temperature from minus 20 to 60 degrees C
  • Self-opening connection terminals, up to 2 x 2.5 mm2

KFA6-STR-1.24.4 technical specifications

The values below are taken from the manufacturer datasheet of the KFA6-STR-1.24.4, release date 2023-02-14. Always confirm the current datasheet and the certificates before final engineering.

Parameter Value
Model KFA6-STR-1.24.4, Power Supply
Supply 92 to 265 V AC, 47 to 63 Hz; terminals 1 (PE), 2 (L1), 3 (N)
Rated current 2.1 to 0.84 A
Recommended back-up fuse B characteristic 16 A or 10 A; C characteristic 6 A
Failure override time More than 75 ms at 230 V AC; 5 ms at 115 V AC
Output voltage 24 V DC, terminals 4+, 6-
Output current 0 to 4 A; Power Rail limited by 4 A slow-blow fuse; electronic limitation typically 4.6 A
Ripple / efficiency Below 100 mV peak-to-peak / typically 87 percent
Voltage limitation Below 28 V DC
Ambient temperature Minus 20 to 60 degrees C
Protection / connection IP20 / self-opening terminals, up to 2 x 2.5 mm2
Dimensions / mass 140 x 101 x 114 mm (W x H x D) / about 800 g
Mounting 35 mm DIN rail according to EN 60715

Check the fuse and mains protection data in the datasheet before wiring, and confirm that the total load stays within the rated output current.

Typical applications in oil and gas, utilities, water and manufacturing

K-System isolated barriers and the Power Rail need a stable 24 V DC supply, and the KFA6-STR-1.24.4 provides it in the same cabinet, directly on the rail or through its own terminals. It is therefore used in marshalling cabinets for oil and gas, power and water plants in Oman and the GCC.

Because the module is designed to match the rest of the system, it keeps the cabinet standardised and makes it easy for maintenance teams to find a replacement. Users also appreciate that a fault is indicated on the front of the module.

Selection and compatibility notes for KFA6-STR-1.24.4

Check the load first. Add up the current of all modules on the rail or on the terminals and compare the sum with the rated output current of the KFA6-STR-1.24.4, leaving margin for starting currents and a rising ambient temperature.

Check the mains supply and its upstream protection. The datasheet lists the input voltage range and the fuse characteristics, and the mains wiring must be done and protected according to your site rules.

Installation and commissioning of the KFA6-STR-1.24.4

Before mounting the KFA6-STR-1.24.4, confirm the mains voltage, the upstream fuse or breaker and the total load of the modules that will be connected. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet, keep mains wiring physically separated from intrinsically safe circuits, and respect the clearances your site rules require. Switch mains off before installation and do not plug or unplug the module while it is powered.

After wiring the KFA6-STR-1.24.4, apply mains, check the green indication and measure the 24 V DC output with no load and with the normal load. Record the values so that later checks can be compared with the commissioning data, and verify that the Power Rail or terminal connections to the downstream modules are tight.

Maintenance and service life

The KFA6-STR-1.24.4 needs little maintenance. During planned shutdowns, check the terminals for looseness and discoloration, verify the output voltage under load, and inspect the fuse and the status LED. In hot cabinets and coastal locations, a clean and dry enclosure with adequate airflow greatly extends the life of any power supply.

If the status LED shows a fault or the output voltage drifts, check the load and the fuse first, then replace the module instead of attempting a repair. Always switch mains off before work, and keep a spare KFA6-STR-1.24.4 on the shelf where a power outage would stop a whole marshalling cabinet.

Related products and ordering notes

Customers who ask for the KFA6-STR-1.24.4 often need neighbouring models or accessories from the same system, such as other K-System isolated barriers, the Power Rail and power feed modules, KFA6 power supplies and the matching NAMUR sensors. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.

When you send an enquiry for the KFA6-STR-1.24.4, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about KFA6-STR-1.24.4

The KFA6-STR-1.24.4 is a regulated 24 V DC, 4 A power supply for the Power Rail with a 92 to 265 V AC input, a replaceable fuse and LED fault indication.

Documents and quotation

A copy of the manufacturer datasheet for the KFA6-STR-1.24.4 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFA6-STR-1.24.4, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
  • PDF Datasheet KFA6-STR-1.24.4 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFA6-STR-1.24.4 Power Supply 24 V DC

Answers from our engineering team on installation, compatibility and integration.

01What does the KFA6-STR-1.24.4 deliver?
It delivers 24 V DC at up to 4 A, either to the Power Rail or to the output terminals.
02What mains voltage can it use?
The supply range is 92 to 265 V AC at 47 to 63 Hz, so it covers both 115 V and 230 V systems.
03How is a fault shown?
A green LED shows normal operation and a flashing red LED shows that a fault exists.
04Which documents are available for the KFA6-STR-1.24.4?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the KFA6-STR-1.24.4.
05How do I order the KFA6-STR-1.24.4?
Send an RFQ with the part number KFA6-STR-1.24.4, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.