Brand:

Pepperl+Fuchs KFA6-SR2-Ex1.W Switch Amplifier, 230 V AC

Description

Pepperl+Fuchs KFA6-SR2-Ex1.W overview

The Pepperl+Fuchs KFA6-SR2-Ex1.W is a one-channel isolated barrier from the K-System of Pepperl+Fuchs that runs on a 230 V AC supply and transfers digital signals from NAMUR sensors or mechanical contacts in a hazardous area to the safe area. The sensor or switch controls a form C changeover relay contact for the safe area load.

The datasheet released on 3 January 2023 states that switch S1 reverses the normal output state and switch S3 enables or disables line fault detection of the field circuit. During an error condition the relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44. The safety integrity level is up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511.

Key features of the Pepperl+Fuchs KFA6-SR2-Ex1.W

  • One-channel isolated barrier powered directly from 207 to 253 V AC
  • Form C changeover relay contact output
  • Dry contact or NAMUR input with line fault detection
  • Reversible mode of operation
  • Up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511
  • Power consumption of up to 1 W
  • Ambient temperature from minus 20 to 60 degrees C
  • Housing type B2, 20 mm wide

KFA6-SR2-Ex1.W technical specifications

The values below are taken from the manufacturer datasheet of the KFA6-SR2-Ex1.W, release date 2023-01-03. Always confirm the current datasheet and the certificates before final engineering.

Parameter Value
Model KFA6-SR2-Ex1.W, Switch Amplifier, 1-channel isolated barrier
Signal type Digital input
Safety integrity SIL 2
Supply 207 to 253 V AC, 45 to 65 Hz, terminals 14, 15
Power dissipation / consumption 1 W / up to 1 W
Input NAMUR acc. to EN 60947-5-6, terminals 1+, 2+, 3-
Open circuit voltage / short-circuit current About 8 V DC / about 8 mA
Switching point / hysteresis 1.2 to 2.1 mA / about 0.2 mA
Line fault detection Breakage 0.1 mA or less; short-circuit above 6 mA
Output Relay, terminals 7, 8, 9; 253 V AC / 2 A / cos phi above 0.7; 126.5 V AC / 4 A; 40 V DC / 2 A resistive
Delay / mechanical life About 20 ms / 10 to the power 7 switching cycles
Switching frequency Less than 10 Hz
Ambient temperature Minus 20 to 60 degrees C
Dimensions / mass 20 x 119 x 115 mm (W x H x D), housing type B2 / about 150 g

The hazardous-area parameters are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.

Typical applications in oil and gas, utilities, water and manufacturing

Position and process switching in hazardous areas relies on NAMUR proximity sensors and dry contacts, from limit switches on emergency shutdown valves at wellheads to level switches on storage tanks and flow switches on cooling water lines. The KFA6-SR2-Ex1.W passes these signals out of the hazardous area to relays, PLC inputs or annunciators, and its line fault detection tells operators when a cable is open or shorted instead of leaving a silent failure.

In power stations, water treatment plants and manufacturing facilities around the GCC, the same module is common on package units, burner management panels and compressor skids. Because the signal is a simple switching state, the KFA6-SR2-Ex1.W is easy to commission, and spare units are often held on the shelf because one failed channel can stop a whole skid.

Selection and compatibility notes for KFA6-SR2-Ex1.W

Check the sensor type first. The input is designed for NAMUR sensors according to EN 60947-5-6 and for mechanical contacts with the resistor network shown in the wiring diagram, so a three-wire sensor or a powered contact needs a different interface. Then check what the safe-area load requires, because a relay output and a transistor output behave very differently with PLC cards, solenoids and counters.

If the signal is part of a safety function, read the functional safety data in the datasheet, including the SIL value and the conditions attached to it, and compare it with your safety requirement specification. When the KFA6-SR2-Ex1.W replaces an older module, compare terminal numbers and the supply arrangement, since the Power Rail option changes how power and the collective error message are wired.

Installation and commissioning of the KFA6-SR2-Ex1.W

Before mounting the KFA6-SR2-Ex1.W, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail, a termination board or its own supply terminals. Mount it in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits.

Wire the KFA6-SR2-Ex1.W only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFA6-SR2-Ex1.W can be compared with the commissioning values.

Maintenance and service life

The KFA6-SR2-Ex1.W has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface.

If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFA6-SR2-Ex1.W entity parameters before it returns to service.

Related products and ordering notes

Customers who ask for the KFA6-SR2-Ex1.W often need neighbouring models or accessories from the same system, such as other K-System isolated barriers, the Power Rail and power feed modules, KFA6 power supplies and the matching NAMUR sensors. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.

When you send an enquiry for the KFA6-SR2-Ex1.W, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about KFA6-SR2-Ex1.W

The KFA6-SR2-Ex1.W is a 230 V AC powered, SIL 2 capable one-channel switch amplifier with a changeover relay output, NAMUR or dry contact input and line fault detection.

Documents and quotation

A copy of the manufacturer datasheet for the KFA6-SR2-Ex1.W is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFA6-SR2-Ex1.W, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFA6-SR2-Ex1.W Switch Amplifier, 230

Answers from our engineering team on installation, compatibility and integration.

01How is the KFA6-SR2-Ex1.W powered?
It runs on 207 to 253 V AC at 45 to 65 Hz through terminals 14 and 15, so no 24 V DC supply is needed.
02What output does it provide?
A form C changeover relay contact on terminals 7, 8 and 9.
03What safety level does it reach?
The datasheet states up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511.
04Which documents are available for the KFA6-SR2-Ex1.W?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the KFA6-SR2-Ex1.W.
05How do I order the KFA6-SR2-Ex1.W?
Send an RFQ with the part number KFA6-SR2-Ex1.W, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.