Brand:

Beamex 8003710 PGL Seal Service Kit for PGL Pump

Description

Beamex 8003710 PGL seal service kit overview

The Beamex 8003710 PGL seal service kit contains all the seals and O-rings that may need replacing in a PGL low pressure calibration pump (-400 to 400 mbar), including the seals for the coarse and fine adjust pistons. An opening tool and a Torx wrench are part of the kit.

Instructions for replacing the seals are in the Maintenance section of the PGL user manual published by Beamex.

This page describes Beamex 8003710 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the PGL seal service kit

  • All seals and O-rings that may need replacing in the pump
  • Includes seals for the coarse and fine adjust pistons
  • Opening tool and Torx wrench included
  • Procedure described in the PGL user manual

Standard delivery and contents according to Beamex:

  • Seals and O-rings for the PGL pump
  • Opening tool
  • Torx wrench

Technical specifications of Beamex 8003710

Order code 8003710
Fits Beamex PGL calibration pump (-400 to 400 mbar)
Contents Seals and O-rings including coarse and fine adjust piston seals
Tools included Opening tool, Torx wrench
Instructions Maintenance section of the PGL user manual

All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.

Typical applications in Oman and the GCC

Hand pumps and electric pumps in calibration workshops wear over time because seals and O-rings are consumables. Maintenance teams in oil and gas, power, water and manufacturing sites across Oman and the GCC keep service kits such as the PGL seal service kit (8003710) so that a pump that has lost pressure holding ability can be restored without waiting for a replacement unit.

Buyers often search for the exact order code because the right kit depends on the model and on the generation of the pump. Quoting 8003710 with your request avoids mix-ups between similar pumps.

Selection and compatibility notes for 8003710

Select the kit by pump model first, then confirm the order code. Beamex lists separate kits for different pumps and sometimes for different generations of the same pump, so only 8003710 should be used with the pump named on this page.

Check the contents against the work you need to do. Some kits cover only part of a pump, while others are full service kits. If in doubt, read the maintenance section of the relevant Beamex manual before ordering.

Installation and commissioning

Depressurize the pump and disconnect all hoses before starting. Work on a clean surface, lay out the removed parts in order and compare them with the new parts. Use only the tools named in the Beamex documentation.

Lightly grease seals only where the manual says so, refit parts in the reverse order of removal and leak-test the pump at low pressure before returning it to service. Keep the manual for 8003710 at hand during the work.

Maintenance and care

Store unused kits in a clean dry place in their packaging. After servicing, record the date so the next service interval is easy to plan.

Do not mix old and new seals in the same assembly. Replace all parts the manual tells you to replace in one session.

Related products and ordering notes

Beamex lists these related items, each with its own order code:

  • 8003725 PGL fine adjust service kit
  • 8003720 PGL coarse adjust service kit
  • 9010090 PGL calibration pump, pump only
  • 8003730 PGL support leg

Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.

Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.

Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.

Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.

When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.

Frequently asked questions about 8003710

What does the 8003710 kit contain? All seals and O-rings that may need replacing in the PGL pump, including those of the coarse and fine adjust pistons, plus an opening tool and Torx wrench.

Which pump is it for? The Beamex PGL calibration pump, which covers -400 to 400 mbar.

Where are the replacement instructions? In the Maintenance section of the PGL user manual published on the Beamex website.

Are tools needed besides those in the kit? The kit includes an opening tool and a Torx wrench. Check the PGL manual for any further tools for your service step.

Are there smaller kits for the PGL? Yes. Beamex also lists coarse adjust (8003720) and fine adjust (8003725) service kits.

Documents and quotation

The official Beamex PGL user manual is attached to this page as a PDF. It references the seal service kit 8003710 (pages 4, 15–16 and 19) and explains the PGL maintenance procedure in which the kit is used. Share order code 8003710 together with your calibrator model and we will confirm the exact part in a written quotation.

Quote Beamex 8003710 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.

Datasheets & Documents
  • PDF Datasheet Beamex PGL User Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8003710 PGL Seal Service Kit for PGL Pump

Answers from our engineering team on installation, compatibility and integration.

01What does the 8003710 kit contain?
All seals and O-rings that may need replacing in the PGL pump, including those of the coarse and fine adjust pistons, plus an opening tool and Torx wrench.
02Which pump is it for?
The Beamex PGL calibration pump, which covers -400 to 400 mbar.
03Where are the replacement instructions?
In the Maintenance section of the PGL user manual published on the Beamex website.
04Are tools needed besides those in the kit?
The kit includes an opening tool and a Torx wrench. Check the PGL manual for any further tools for your service step.
05Are there smaller kits for the PGL?