Brand: Magnetrol
Magnetrol 089-9120-001 Cable Weight Assembly for Eclipse 706 Probe
Description
Magnetrol 089-9120-001 overview: cable weight assembly
The Magnetrol 089-9120-001 is the weight assembly used at the bottom of the flexible single cable guided wave radar probe. It belongs to the Eclipse Model 706 guided wave radar level transmitter, and it appears in the replacement parts section of the manufacturer instruction manual 57-606. Maintenance teams search for spare parts by this exact number because the same product family has many variants, and the wrong board, kit or displacer can leave a loop out of service.
The picture on this page shows the Eclipse Model 706 guided wave radar level transmitter that the Magnetrol 089-9120-001 fits. It is the manufacturer product image for the family and not a close-up of the cable weight assembly itself. Every value on this page comes from the manufacturer catalog and manual for that family, and where a value is not published there we have left it out instead of guessing.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list 089-9120-001 so that buyers can quote the number exactly as it appears in the manual, and we confirm availability against your quotation request.
Key features of 089-9120-001
- Exact manufacturer part number 089-9120-001 for the cable weight assembly.
- Function: the weight assembly used at the bottom of the flexible single cable guided wave radar probe.
- Host product: Eclipse Model 706 guided wave radar level transmitter, described by the manufacturer as a loop-powered guided wave radar transmitter for level, interface, volume and flow, with a four-button keypad and a graphic LCD.
- Listed in manual 57-606, which is the reference for fitting and for the model code digits that select the part.
- Quoted against the model number and serial number of your instrument so the variant can be checked.
Technical specifications for 089-9120-001
The first table records what the manual states about the part itself. The second table gives the main data of the host instrument from the catalog, which helps confirm that the part suits the installation. No pricing appears on this page.
Part data for 089-9120-001
| Item | Value |
|---|---|
| Part number | 089-9120-001 |
| Item | Cable weight assembly (item 10) |
| Model code match | Probe model digit 3 = 1 (7y1 single cable probe) |
| Fits | Eclipse Model 706 flexible single cable probe |
Host instrument data: Eclipse 706
| Item | Value |
|---|---|
| Measurement principle | Guided wave radar based on time domain reflectometry (TDR) |
| Span | 6 inches to 100 feet (15 cm to 30 m); Model 7yS steam probe 20 feet (610 cm) maximum |
| Output | 4 to 20 mA with HART (3.8 to 20.5 mA usable), FOUNDATION fieldbus H1 or PROFIBUS PA |
| HART supply at terminals | 16 to 36 VDC, two-wire loop powered |
| Housing | IP66/IP67, die-cast aluminum A413 (less than 0.4 percent copper), optional stainless steel |
| Weight (aluminum housing) | 2.0 kg (4.5 lb) |
| Operating temperature (electronics) | -20 to +70 degrees C (-5 to +160 degrees F) |
| Media dielectric constant | 1.2 to 100 |
| Probe design limit | Up to +450 degrees C and 431 bar (+850 degrees F, 6250 psi) |
| Safety | SIL 2/3 capable, safe failure fraction 93 percent (HART only) |
Typical applications in oil and gas, utilities, water and manufacturing
Guided wave radar is used for level and interface on separators, drums, condensate and chemical tanks, and water vessels where a contact probe is acceptable. The manufacturer states that level measurement is not affected by changing media characteristics and that no level change is needed for calibration, and the catalog lists applications from very light hydrocarbons to water-based media. For saturated steam duty the catalog describes a coaxial steam probe used in a side-mounted chamber.
In Oman and the GCC, instruments of this kind are found in oil and gas production and processing, petrochemical and refining units, power and desalination plants, water and wastewater works, and general manufacturing. A replacement cable weight assembly such as 089-9120-001 is normally ordered during a turnaround or after a fault, when the loop must return to service quickly, so having the exact number in hand saves time.
Selection and compatibility notes for 089-9120-001
- Match probe digit 3: the manual lists 089-9120-001 for the 7y1 single cable probe and a different cable weight for the 7y2 probe.
- Replace the weight assembly if it is damaged or lost during probe removal.
- Provide the probe model number so the correct style is confirmed before shipment.
Please treat the model code and the serial number on the nameplate as the final authority. If your instrument is older than the manual revision we reference, send the nameplate photo and we will tell you whether 089-9120-001 is listed for it before you commit to an order.
Installation and commissioning of 089-9120-001
Follow the installation section of manual 57-606 and its warnings. In particular, do not connect or disconnect energized equipment in a hazardous area unless power has been switched off or the area is known to be non-hazardous, and keep the housing covers and O-rings in good condition so the enclosure rating is kept.
- The housing rotates through 360 degrees and can be separated from the probe without depressurizing the vessel, which simplifies work on a live process, subject to the manual warnings.
- The transmitter can be remote-mounted up to 3.6 m (12 feet) from the probe when the display and keypad remote option is ordered.
- Configuration is done from the local keypad or with PACTware and the Model 706 DTM, or a HART communicator, and the echo curve can be viewed for diagnosis.
Maintenance and spares planning
Spare parts for process instruments are best planned from the nameplate data of each installed unit. For this family, the manufacturer lists the parts in groups, so related items are easy to review together with 089-9120-001. Keep a record of the model number, serial number and the digits that selected the part, and store electronic parts in antistatic packing until fitting. After any replacement, check the output against a known reference and record the result in the loop file.
Related products and ordering notes
Other numbers in the same manual section may suit sister variants, for example the alternatives listed in the table above. Ask us about the whole spares list for a unit if you are building a turnaround kit, and send the instrument model with every request so that 089-9120-001 is checked against it. Availability and lead time depend on stock and on the source, and we give them with the quotation.
FAQ summary for 089-9120-001
Buyers most often ask what 089-9120-001 is, which instrument it fits, whether Seven Star LLC can supply it in Oman, whether a manual is available, and what to send with a request. The answers are given in the FAQ list on this page, and in short: 089-9120-001 is the manufacturer number for the cable weight assembly of the Eclipse 706, and we need the model number, serial number, quantity and delivery location to quote.
Documents and quotation
The manufacturer manual 57-606 that lists 089-9120-001 is attached to this page as a PDF for reference, so you can check the part drawing and the model code table yourself. To obtain a quotation, send an RFQ with the part number 089-9120-001, the quantity, the instrument model and serial number, and the delivery location. Seven Star LLC replies with availability and lead time.
Other Models in the Magnetrol 706 Range
Seven Star LLC supplies models from the Magnetrol 706 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z31-2849-001 Electronic Module for Eclipse 706 GWR | Radar & Guided Wave Radar Level | View details |
| Magnetrol 089-9136-001 Display Module for Eclipse 706, Pulsar R96 | Radar & Guided Wave Radar Level | View details |
| Magnetrol 089-9120-001 Cable Weight Assembly for Eclipse 706 Probe | Radar & Guided Wave Radar Level | You are viewing this model |
Datasheets & Documents
- Manual Magnetrol 089-9120-001 Cable Weight Assembly for Eclipse 706 Probe Manual with Parts List Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 089-9120-001 Cable Weight Assembly for
Answers from our engineering team on installation, compatibility and integration.
01What is 089-9120-001?
089-9120-001 is the Magnetrol part number for the cable weight assembly of the Eclipse Model 706 guided wave radar level transmitter. It is listed in the replacement parts section of the manufacturer manual 57-606.
02Which instrument does 089-9120-001 fit?
It is listed for the Eclipse Model 706 guided wave radar level transmitter. The model code digits shown on this page select the exact variant, so please confirm the model and serial number with us before ordering.
03Can Seven Star LLC supply 089-9120-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with 089-9120-001, the quantity and the delivery location and we will confirm availability.
04Is a manual available for 089-9120-001?
Yes. The manufacturer manual 57-606 that contains the parts list for 089-9120-001 is provided as a PDF on this page, so you can check the drawing and the model code table.
05What should I send with an RFQ for 089-9120-001?
Send the part number 089-9120-001, the quantity, the instrument model number and serial number, the supply or approval details on the nameplate, and the delivery location so we can prepare an accurate quotation.