Brand: MICHELL Instruments
Michell PTS-WDC Promet Water Dew-Point Sensor Assembly
Description
Michell PTS-WDC overview: water dew-point sensor assembly for the Promet
Michell PTS-WDC is listed on the Michell order-code sheet for the Promet EExd as the water dew-point sensor assembly with pressure transmitter. It is the replaceable measuring element of the Promet and is the usual spare to hold for plants that rely on the analyzer for pipeline moisture compliance.
The same sheet lists PTS-SX-WDC as the service calibration exchange replacement of the assembly, which lets operators swap in a freshly calibrated sensor and return the installed one.
The Promet datasheet describes the sensing technology as the Michell ceramic metal-oxide moisture sensor, with automatic pressure-compensated conversions and a calibration range of minus 100 to plus 20 degrees Celsius dew point.
The image shows the Promet EExd analyzer from the manufacturer datasheet, the host instrument of this assembly; it is not a close-up of the sensor assembly.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell PTS-WDC so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of PTS-WDC
- Water dew-point sensor assembly supplied with a pressure transmitter, per the manufacturer order-code sheet.
- Service calibration exchange version listed as PTS-SX-WDC.
- Used with the Promet EExd main unit PT-MON for single or dual channel moisture measurement.
- Ceramic metal-oxide moisture sensing technology with traceable calibration.
PTS-WDC technical specifications
The manufacturer lists PTS-WDC by name only; the values below describe the host Promet EExd instrument that uses the assembly.
| Parameter | Value |
|---|---|
| Order code | PTS-WDC |
| Description (manufacturer) | Water dew-point sensor assembly (with pressure transmitter) |
| Exchange item | PTS-SX-WDC, service calibration exchange replacement |
| Host instrument | Promet EExd, PT-MON |
| Sensor technology (host) | Michell ceramic metal-oxide moisture sensor |
| Calibration range (host) | Minus 100 to plus 20 degC dp |
| Host measurement range | Minus 120 to plus 30 degC dp |
| Host pressure accuracy | Plus or minus 0.25 percent of full scale |
Typical applications of PTS-WDC in Oman and the GCC
- Replacing the moisture sensor of a Promet on a natural gas export line.
- Keeping calibrated spares for glycol dehydration unit monitoring.
- Scheduled sensor exchange to maintain traceable calibration.
Spare parts are what keep an installed analyzer running through a shutdown window. Plants in Oman and the GCC often hold single critical spares on site because lead times from overseas can be long, and a clear, exact part number such as PTS-WDC removes ambiguity when a maintenance planner raises a purchase request.
Selection and compatibility notes
State whether you need the new assembly PTS-WDC or the service exchange item PTS-SX-WDC, and give the Promet serial number and channel configuration so that we can match the pressure transmitter range.
Spare parts for process analyzers are not interchangeable by description alone. Before ordering PTS-WDC, give us the model code and serial number of the host instrument, because variants and production years can use different assemblies, and we will compare them against the manufacturer spares list.
Installation and commissioning of PTS-WDC
Replace the assembly only with the sample isolated and depressurised and under the permit required for flameproof equipment, and follow the Promet manual. After replacement, leak-check the sample connections and confirm the dew point against the previous reading.
Fit this item only when the analyzer is isolated, depressurised and de-energised according to your permit-to-work, and follow the service instructions in the manufacturer manual. After replacement, re-verify the instrument against a known reference, check for leaks on any wetted parts, and record the change in the maintenance log.
Maintenance, calibration and service
Keep the removed assembly labelled with its position and serial number if it is to be returned under the exchange scheme, and record the calibration date of the new one.
Keep a replacement log that shows the date of fitting, the instrument serial number and the reason for the change, so that future failures can be correlated with operating conditions. Store spares in clean, dry packaging at moderate temperature until they are needed.
Related products and ordering notes for PTS-WDC
- PT-MON: Promet EExd main unit.
- PT-SFK: filter kit for coalescer and membrane separator.
- PTS-GAC: glycol adsorption cartridges, pack of 10.
When you request PTS-WDC, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about PTS-WDC
- What is PTS-WDC? PTS-WDC is the manufacturer code for the water dew-point sensor assembly with pressure transmitter used in the Promet EExd analyzer.
- What does PTS-WDC suit? It is a spare for Promet EExd analyzers, matched by channel and pressure configuration.
- What is PTS-SX-WDC? The manufacturer lists PTS-SX-WDC as the service calibration exchange replacement of the same assembly.
- What should I send with an RFQ for PTS-WDC? Send the part number PTS-WDC, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The Promet datasheet describes the host instrument.
Documents and quotation
The official Michell Instruments Promet EExd Process Moisture Analyzer datasheet is attached to this page as a PDF. The six-page datasheet describes the Michell ceramic moisture sensor used in this assembly on page 2, with every Promet EExd sensor calibrated against fundamental dew-point systems traceable to NPL (UK) and NIST (USA), and lists a range of -120 to +30 °C dew point (0.001 to 30,000 ppmV) with sour-gas compatibility. Quote part number PTS-WDC and your analyzer serial number in your request so we can check the match before we send a written quotation.
Other Models in the Michell Promet Range
Seven Star LLC supplies models from the Michell Promet range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell PT-MON Promet EExd Process Moisture Analyzer Main Unit | Gas Analyzer Systems | View details |
| Michell PTS-WDC Promet Water Dew-Point Sensor Assembly | Gas Analyzer Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet Michell Promet EExd Process Moisture Analyzer Datasheet (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell PTS-WDC Promet Water Dew-Point Sensor
Answers from our engineering team on installation, compatibility and integration.
01What is PTS-WDC?
PTS-WDC is the manufacturer code for the water dew-point sensor assembly with pressure transmitter used in the Promet EExd analyzer.
02What does PTS-WDC suit?
It is a spare for Promet EExd analyzers, matched by channel and pressure configuration.
03What is PTS-SX-WDC?
The manufacturer lists PTS-SX-WDC as the service calibration exchange replacement of the same assembly.
04Can Seven Star LLC supply PTS-WDC in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for PTS-WDC?
Send the part number PTS-WDC, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The Promet datasheet describes the host instrument.


















Reviews
There are no reviews yet.