Brand:

Fluke 772 Milliamp Process Clamp Meter

Description

772 milliamp process clamp meter for 4 to 20 mA loops

The Fluke 772 is a handheld milliamp process clamp meter. Its clamp reads a 4 to 20 mA loop signal through the insulation without breaking the loop, and its test jacks let the same instrument source or simulate a 4 to 20 mA signal and supply 24 V loop power to a transmitter. It is the middle model between the clamp-only 771 and the more versatile 773 which also sources and measures dc voltage. Seven Star LLC supplies the 772 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The ordering list calls the product “Fluke-772 Milliamp Process Clamp Meter”. The functions of the three related models are shown here.

Model Functions Typical use
771 mA clamp measurement only Non-intrusive reading of 4 to 20 mA loops
772 Clamp, in-circuit mA, mA source, mA simulate, 24 V loop power Loop checks and I/O tests without a separate calibrator
773 All 772 functions plus dc voltage source and measure, scaled mA output, mA in/out Valve, isolator and voltage-input testing

772 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 772
mA measurement by clamp 0 to 20.99 mA: 0.2 % + 5 counts; 21.0 to 100.0 mA: 1 % + 5 counts
mA measurement in series (test jacks) 0 to 24.00 mA, 0.2 % + 2 counts
mA source 0 to 24.00 mA, 0.2 % + 2 counts; maximum drive 24 mA into 1,000 Ω
mA simulate 0 to 24.00 mA, 0.2 % + 2 counts; maximum voltage 50 V dc
Loop power 24 V, measured at the same time as in-circuit mA
Output modes Linear ramp or 25 % step for remote testing
Influence of earth field < 0.12 mA
Batteries / working hours Four AA alkaline / 12 hours at 12 mA source into 500 Ω
Operating / storage temperature -10 °C to 50 °C / -25 °C to 60 °C
IP rating IP40
Size / weight 41.3 x 76 x 248 mm / 415 g
Drop test Passes 1 m drop (except the jaw)
Warranty Three years; one year on the mA clamp assembly and cable
Supplied with Soft case, test leads, alligator clips, hanging strap, manual

How the 772 measures a loop without breaking it

In a 4 to 20 mA loop the signal is a current of 4 mA at the bottom of the range and 20 mA at the top. Opening the loop to insert a meter interrupts the control system and may trip alarms. The clamp in the 772 senses the magnetic field of the loop wire, so the reading is taken without any interruption. Because the field is small, the instrument is sensitive to the earth’s magnetic field, with an influence of less than 0.12 mA, so zero it away from large steel and use the same orientation for repeated readings. The datasheet also notes an additional 1 mA error when the clamp is used in a field of 1 V/m to 3 V/m.

When the clamp is not suitable, the test jacks measure current in series with 0.2 % + 2 counts accuracy, which is better than the clamp ranges, and loop power of 24 V supplies a transmitter on the bench.

Source and simulate modes on the 772

Source mode drives a 4 to 20 mA signal into a load such as an input card or an I/P converter, up to 24 mA into 1,000 Ω. Simulate mode makes the instrument act like a transmitter on a loop powered by the control system, with the maximum voltage of 50 V dc. Linear ramp and 25 % step outputs allow one person to test a loop while the controller operator watches the response, with outputs changing automatically.

Selecting the 772

  • Choose the 772 when technicians need to source or simulate 4 to 20 mA signals as well as measure them.
  • Choose the 771 for clamp-only checks and the 773 if you also test 0 to 10 V or 1 to 5 V inputs.
  • Confirm that loop current stays within 100 mA for the clamp ranges.
  • Check that load resistance is within the 1,000 Ω source limit.
  • Add spare AA batteries and keep the leads supplied.

Use and maintenance of the 772

Install four AA batteries, press the mode button for the desired function and keep the jaw clear of large magnetic bodies during zeroing. Check the jaw closes cleanly because dirt or paint in the joint will affect the reading. A drop test is passed apart from the jaw, so handle the clamp assembly with care and store it in the soft case. Plan a periodic verification against a reference milliamp source; the one-year cover on the clamp assembly and cable suggests it is the part most subject to wear.

Typical applications of the 772 in Oman and the GCC

Instrument technicians use the 772 in oil and gas, power, desalination and petrochemical plants to check transmitters, positioners and DCS or PLC analogue channels. The clamp allows loop readings during a running process, while source and simulate modes support commissioning and loop checks during shutdowns. The IP40 rating means the tool should be protected from dust and water, and the operating limit is 50 °C, so avoid leaving it in direct sun.

Information to send with an RFQ for the 772

  • Part number 772 (or 771 / 773 if you want to compare)
  • Quantity and spare accessories
  • Loop types, supply voltages and load resistances
  • Delivery location and time frame
  • Calibration certificate requirement

Storage, handling and spares for the Fluke 772

Keep the Fluke 772 in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 772, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet covering the 772 and 773 is attached on this page.

Send us the part number 772 and the quantity and we will confirm availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 772 Milliamp Process Clamp Meter

Answers from our engineering team on installation, compatibility and integration.

01What does the Fluke 772 measure?
The 772 measures 4 to 20 mA loop signals with a clamp without breaking the loop, measures current in series through test jacks, and sources and simulates 0 to 24 mA signals.
02What is the accuracy of the Fluke 772 clamp?
From 0 to 20.99 mA the clamp reads to 0.2 % + 5 counts, and from 21.0 to 100.0 mA to 1 % + 5 counts. Series current through the jacks is 0.2 % + 2 counts.
03How does the Fluke 772 differ from the 773?
The 773 adds dc voltage source and measure, scaled mA output and simultaneous mA in/out. The 772 does not have voltage functions and is limited to milliamp tasks.
04Can the Fluke 772 power a transmitter?
Yes. It provides 24 V loop power and can measure the mA in circuit while powering the transmitter, which is useful for bench testing a device.
05What batteries does the Fluke 772 use?
It uses four AA alkaline cells. The datasheet gives 12 hours of working time at 12 mA source into 500 ohms, and power saving features include auto-off and backlight timeout.