Brand: Schneider Electric
Schneider Electric C10N1TM063 NSX100N 1P 63 A AC/DC Breaker
Description
Choosing the C10N1TM063: a 63 A one-pole NSX100N for AC and DC feeders
The C10N1TM063 is the 63 A version of the one-pole ComPacT NSX100N moulded-case breaker from Schneider Electric. Its datasheet title reads: Circuit breaker ComPacT NSX100N AC/DC, 25kA at 240VAC, TMD trip unit 63A, 1 pole 1d. It protects one conductor, uses a fixed thermal-magnetic trip unit and fits into a body 35 mm wide, which makes it a compact way to protect a mid-sized single-pole feeder. Seven Star LLC supplies the C10N1TM063 in Oman and the GCC as an independent supplier in Muscat.
Reading the part number with the datasheet beside it: C10 stands for the NSX100 frame, N for the breaking-capacity class (datasheet code: N 25 kA 240 V AC), 1 for one pole, TM for the thermal-magnetic trip unit and 063 for the 63 A rating. The datasheet gives the poles description as 1P with 1D protected.
What the 63 A rating means for heat and loading
The thing that most separates the C10N1TM063 from lower ratings in the same frame is how much heat it produces. The datasheet gives a power dissipation of 8.61 W per pole at its rated current. That figure is more than twice the 4.01 W given for the 20 A C10N1TM020 in the same housing, even though the housing is identical. In a ventilated cabinet this is minor; in a sealed, sun-exposed enclosure a row of several such breakers contributes noticeably to internal temperature.
Since the C10N1TM063 rated current is stated at 40 °C, a designer should compare 63 A with the real air temperature around the breaker, not the room temperature of the control building. If the enclosure runs hot in Gulf summer conditions, a conservative loading margin or better ventilation protects both the breaker and the cables connected to it.
Technical specifications of the C10N1TM063
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / C10N1TM063 |
| Range / product name | ComPacT / ComPacT NSX |
| Device short name | NSX100N |
| Product type | Circuit breaker, distribution application |
| Poles / protected poles | 1P / 1D |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 277 V AC 50/60 Hz; 250 V DC |
| Network type | AC; DC |
| Breaking capacity (Icu) | 25 kA at 220/240 V AC 50/60 Hz; 50 kA at 250 V DC (IEC 60947-2) |
| Breaking capacity code | N 25 kA 240 V AC |
| [Ics] rated service breaking capacity | 25 kA at 220/240 V AC; 50 kA at 250 V DC |
| Trip unit | TM-D, thermal-magnetic, protection functions LI |
| [Ir] long-time pick-up | 1 x In, fixed |
| [Ii] instantaneous pick-up | 500 A, fixed |
| Protection types | L overload (thermal); I short-circuit (magnetic) |
| Suitability for isolation | Yes, EN/IEC 60947-2; Category A |
| [Ui] / [Uimp] | 750 V AC 50/60 Hz / 8 kV |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 277 V In/2; 10000 cycles at 277 V In |
| Power dissipation per pole | 8.61 W |
| Control / mounting mode | Toggle / fixed, on backplate |
| Mounting position | Horizontal and vertical; flat on the back |
| Connections | Front, upside and downside; pitch 35 mm |
| Dimensions W x H x D | 35 x 161 x 86 mm |
| Net weight | 0.7 kg |
| Standards | EN/IEC 60947-2 |
| Protection degree | IP40 (IEC 60529); IK07 (IEC 62262); Class II on front face |
| Pollution degree / overvoltage category | 3 / IV |
| Relative humidity | 0 to 95 % |
| Operating altitude | 0 to 2000 m without derating; 2000 to 5000 m with derating |
Fixed trip settings of the C10N1TM063 and what they imply
The trip unit is a TM-D with the protection functions L and I. Overload protection is thermal, with a fixed long-time pick-up of 1 x In and a fixed delay, and short-circuit protection is magnetic with a fixed instantaneous pick-up of 500 A. There are no adjustment dials on the C10N1TM063. For the user this means the curve is known from the part number alone, which simplifies spares and documentation.
The 500 A threshold is roughly eight times the rated current. Loads with brief starting peaks, for example a group of fan motors or a transformer energising, should be checked against that value. If the peak is above 500 A, the C10N1TM063 will trip on switching rather than on a real fault, and a different breaker type would be required.
Voltage and fault-level limits for the C10N1TM063
On AC the datasheet limits the breaker to 277 V at 50/60 Hz and an Icu of 25 kA at 220/240 V. On DC the limit is 250 V with an Icu of 50 kA. The service breaking capacity Ics matches the Icu values in both cases. A one-pole breaker like this is usually applied to one phase to neutral or to one polarity of a DC circuit; the installation design should confirm that a single break is acceptable for the circuit and that voltage across the pole never exceeds the stated values.
Insulation data: rated insulation voltage 750 V AC at 50/60 Hz and rated impulse withstand voltage 8 kV. The datasheet also lists Category A utilisation, overvoltage category IV and pollution degree 3.
Mounting and servicing the C10N1TM063
The breaker is fixed-mounted on a backplate and can be installed horizontally, vertically or flat on its back. Cables enter at the front on both ends, with a 35 mm pitch. Because the breaker has a toggle handle and Class II protection on the front face, the handle is the only part the operator touches. IP40 and IK07 are the degrees listed; anything more demanding in terms of water or dust needs an enclosure around it.
For service planning, the datasheet gives mechanical durability of 20000 cycles and electrical durability of 20000 cycles at 277 V and In/2, falling to 10000 cycles at 277 V and In. When the 63 A is regularly loaded close to its limit and operated often as a switch, those electrical figures set the review interval. After a trip, find the cause first; a thermal-magnetic breaker is not a substitute for finding an overload.
Where a 63 A one-pole breaker is used in the region
Typical uses for the C10N1TM063 include single-phase distribution sub-circuits in commercial buildings, 250 V DC supplies for battery and control systems in substations and plants, and feeders to small process equipment in oil and gas, desalination and power facilities in Oman and the GCC. Heat, fine dust and coastal humidity are the three conditions that matter most. The datasheet allows relative humidity from 0 to 95 % and operation up to 2000 m without derating, which covers most sites in the region.
Comparing the C10N1TM063 with other ratings in the series
The same NSX100N one-pole body is also offered with lower ratings. The table compares the C10N1TM063 with the 20 A C10N1TM020 using their datasheet values.
| Part number | Rated current In | Instantaneous pick-up | Dissipation per pole |
|---|---|---|---|
| C10N1TM020 | 20 A | 190 A | 4.01 W |
| C10N1TM063 | 63 A | 500 A | 8.61 W |
RFQ checklist for the C10N1TM063
- The exact part number C10N1TM063 and quantity.
- Whether the circuit is AC or DC, the voltage and the available short-circuit current.
- Expected continuous current and peak starting current.
- Panel ambient temperature and whether the enclosure is ventilated.
- Delivery location and required documents.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Compact Nsx100n 1p Range
Seven Star LLC supplies models from the Se Compact Nsx100n 1p range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric C10N1TM020 NSX100N 1P 20 A AC/DC Breaker | Circuit Breakers | View details |
| Schneider Electric C10N1TM063 NSX100N 1P 63 A AC/DC Breaker | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric C10N1TM063 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric C10N1TM063 NSX100N 1P 63 A AC/DC
Answers from our engineering team on installation, compatibility and integration.
01What is the instantaneous pick-up of the C10N1TM063?
The datasheet gives a fixed instantaneous (magnetic) pick-up of 500 A. The long-time pick-up is fixed at 1 x In, so neither can be adjusted.
02How much heat does the C10N1TM063 dissipate?
The datasheet lists 8.61 W per pole. That is the figure to use when estimating the temperature rise inside a closed enclosure.
03Is the C10N1TM063 rated for DC?
Yes. It is rated for 250 V DC with an Icu of 50 kA at 250 V DC, as well as 277 V AC at 50/60 Hz with 25 kA at 220/240 V AC.
04How many poles does the C10N1TM063 protect?
One. The datasheet gives the poles description as 1P and protected poles as 1D, so it is a single-pole device.
05What are the dimensions and weight of the C10N1TM063?
35 mm wide, 161 mm high and 86 mm deep, with a net weight of 0.7 kg according to the datasheet.


















Reviews