Brand: Danfoss
Danfoss 031E020066 CS Pressure Switch 2-6 bar 3-Pole
Description
CS pressure switch with three-pole contact for compressors and pump sets
The 031E020066 is the Danfoss CS, a pressure switch whose built-in three-pole contact can start and stop a small motor without a separate contactor. The data sheet positions it for automatic start and stop of air compressors and water boosters. This code is set 2 to 6 bar with a G 1/4 female connection, a diaphragm element and an IP43 cover, which fits the pressures of a domestic or light-commercial booster or a workshop compressor.
A manual switch on the cover locks the contact system open independently of the pressure, so the pump can be taken out of service for maintenance without touching the wiring. Relief valves are available as accessories for compressors that need pressure relief on the piston before start.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 031E020066 |
| Type | CS |
| Function | Pressure switch for air compressors and water boosters |
| Setting range | 2 to 6 bar |
| Differential | 0.72-1 bar at minimum setting; 1-2 bar at maximum setting |
| Contact system | TPST, three-pole |
| Contact rating | AC3=12 A, 220 – 415 V; AC3=9 A, 600 V; DC13=2 A, 220 V; DC14=2 A, 220 V |
| Enclosure | IP43 |
| Pressure connection | G 1/4 female, ISO 228-1 |
| Max. working pressure | 6 bar |
| Max. test pressure | 10 bar |
| Pressure element | Diaphragm |
| Ambient temperature | -20 to 70 C |
| Cable entry | Pg 16 |
| Approvals as listed | CE; EAC; LVD; RoHS; TYSK; UA |
| Net weight | 0.45 kg |
| EAN | 5702423208845 |
Sizing the contact and the differential
The contact ratings of 12 A at 220-415 V (AC3) and 9 A at 600 V mean the switch can take a three-phase motor of a few kilowatts directly; above that, drive a contactor. The differential is adjustable from 0.72 to 2 bar depending on where the range spindle sits, which is what controls the number of starts per hour. A booster set with a small pressure vessel needs a wider differential than one with a large vessel.
The maximum working pressure of 6 bar equals the top of the range, so the CS is intended for low-pressure systems. For higher air pressure the data sheet offers other CS types with ranges up to 20 bar. Do not set the cut-out within a few tenths of a bar of the 6 bar working limit.
Mounting and what to check
Fit the G 1/4 female connection to a clean tapping and keep the switch upright. The Pg 16 cable entry takes a standard motor cable; an optional Pg 16 gland is available as an accessory. For drinking water, Danfoss lists special versions with polyacetal pressure connections, which are different code numbers.
Before ordering, confirm supply voltage and motor power against the contact rating, check that a manual switch version is what you need and decide whether a pressure relief valve is required. Seven Star LLC is an independent supplier in Muscat; send 031E020066 and the quantity for a quotation.
Our quotation for 031E020066 will state what is included, such as the document set and the packing, and what is not, for instance accessories or commissioning. Read these lines against your specification, and ask us to adjust the scope if your project requires something extra.
Where the switch sits in a booster or compressor system
In a typical water booster set, the switch senses discharge pressure close to the pressure vessel. When demand draws the pressure down to the cut-in point, the contact closes and the pump starts; when the vessel refills to the cut-out point, the contact opens and the pump stops. In a small air compressor the logic is the same, with the receiver taking the place of the vessel. Because the CS switches the motor directly, the control circuit can be very simple, though motor overload protection must still be provided separately in line with local wiring rules.
The tapping point matters. A connection on a turbulent section of pipe, or one exposed to pressure surges from a check valve closing, can cause chattering or early wear. A short, steady branch close to the vessel or receiver gives cleaner switching.
Setting cut-in and cut-out in practice
The range spindle sets the cut-out and the differential spindle sets the gap to the cut-in. A practical approach is to choose the lowest pressure the users can accept, add the differential needed to keep motor starts within the motor maker’s limit, and then confirm that the resulting cut-out sits comfortably below the working pressure limit. Settings should be checked against a calibrated gauge during commissioning rather than relying on the scale alone.
Installation and commissioning practice
Before connecting the switch, the system should be flushed so that sand, scale or thread sealant does not reach the diaphragm. Thread sealing should be applied sparingly on the male fitting only. The supply must be isolated during wiring, and the cable gland tightened so that the cover seal can do its job. After wiring, a few test cycles with the gauge in view confirm that the pump or compressor starts and stops at the intended pressures, and that the manual switch locks the contact open as expected.
Service in GCC climate conditions
Booster sets on rooftops and compressors in workshops across Oman and the Gulf often operate in direct sun, dust and humid coastal air. The ambient temperature limit in the table should be compared with the real surface temperature of the switch location, which can be much hotter than the shade air temperature on an exposed roof. Shading the switch, or mounting it inside a ventilated pump-room, reduces heat stress. The IP43 cover offers basic protection, so a position away from direct water spray and blowing sand is preferable.
Maintenance checks
Periodic checks should look for drift in the switching points, pitting or burning signs reported by unusual motor behaviour, loose terminals and damaged cable entries. Frequent short cycling usually points to a waterlogged pressure vessel or a leaking check valve rather than a faulty switch, so the system should be examined before replacing the unit. In compressors, condensate and oil carry-over in the sensing line should also be watched.
Documents and quotation
We attach the Danfoss CS pressure switch data sheet AI547816451399 with applications and wiring examples. See also pressure instrumentation.
Datasheets & Documents
- Datasheet Danfoss CS pressure switch data sheet AI547816451399 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
A CS pressure switch with a 2 to 6 bar range, three-pole TPST contact, G 1/4 female connection, diaphragm element and IP43 enclosure.
The three-pole contact is rated for 12 A at 220 to 415 V (AC3), so small motors can be switched directly; larger motors need a contactor.
The store lists 6 bar maximum working pressure and 10 bar test pressure for this code.
Yes. A manual switch locks the contact system open regardless of system pressure, according to the data sheet.
The Danfoss CS pressure switch data sheet AI547816451399 in unaltered form.