Danfoss 060-110166 KP 1 Low Pressure Switch -0.2 to 7.5 bar
Description
A KP 1 low-pressure switch with automatic reset for compressor protection
The 060-110166 is the Danfoss KP 1, the standard low-pressure member of the KP range. A single bellows element senses the suction pressure at its 1/4 in male flare connection and flips an SPDT snap-action contact when the pressure falls to the cut-out value, then flips it back when the pressure has recovered by the set differential. Regulation covers -0.2 to 7.5 bar, so it handles everything from deep vacuum-side protection up to typical R404A or R134a suction levels, and the automatic reset means the compressor restarts on its own once suction pressure returns.
Danfoss describes the KP series as protection against excessively low suction pressure or excessively high discharge pressure, and as a way to start and stop compressors and condenser fans. The contact can drive a single-phase AC motor of about 2 kW directly; larger motors and DC loads are switched through a contactor in the control circuit. This particular code carries the IP44 enclosure option rather than the open IP30 version, which makes it a better fit for plant rooms where condensation or splashing is possible.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 060-110166 |
| Type | KP1 |
| Function | Low-pressure (suction side) switch with auto reset |
| Regulating range | -0.2 to 7.5 bar (6 inHg to 108 psig) |
| Differential (adjustable) | 0.7 to 4.0 bar (10 to 58 psi) |
| Contact system | SPDT, single-pole double-throw |
| Contact rating | AC15=10 A, 400 V; AC1=16 A, 400 V; AC3=16 A, 400 V; DC13=12 W, 220 V; LR=112 A, 400 V |
| Enclosure | IP44 |
| Pressure connection | 1/4 in male flare, DIN 8906 |
| Max. working pressure (PS) | 17 bar (245 psig) |
| Max. test pressure | 20 bar (290 psig) |
| PED category | IV |
| Pressure element | Welded bellows |
| Ambient temperature | -25 to 65 C; 80 C for max. 120 min |
| Cable entry | Rubber cable gland for 6-14 mm cable |
| Packing | Multi pack, 36 pcs |
| Approvals as listed | BV; CCC; CE; CMIM; DNV; EAC; GL; LR; LVD; PED; RINA; RoHS China; c UL us UL353, CS C22.2; c UL us UL873, CS C22.2; UA |
| Net weight | 0.3 kg |
| EAN | 5702422002185 |
Setting the cut-in, cut-out and differential
Two spindles under the cover set the switch. The range spindle fixes the cut-in pressure on the scale, and the differential spindle moves the cut-out below it. With a 0.7 to 4.0 bar differential window, a cut-in of 2.0 bar and a differential of 1.0 bar gives a cut-out at 1.0 bar. Keep the differential wide enough to prevent short-cycling of the compressor, and choose the cut-out from the lowest suction pressure your refrigerant and evaporator allow.
A manual trip lever lets you test the contact function without any tools and without changing pressure, which is useful during commissioning. The data sheet also lists a fail-safe double-bellows construction for the KP 6, KP 7, KP 17 and KP 47 types; the KP 1 uses the single welded bellows, so where a failure of the element itself must lead to a safe state, discuss the alternative types before ordering. The store entry for this code notes that it is not applicable for a liquid line.
Installation notes and what to confirm before ordering
Mount the switch on a flat, vibration-free surface and keep the pressure line short and clean so that dirt and oil do not collect at the bellows. Run the cable through the supplied rubber gland for 6 to 14 mm cables and terminate it according to the diagram inside the cover. Check that the cabinet or plant room fits the ambient window of -25 to 65 C.
Confirm the refrigerant against the approved list printed for this code on the Danfoss product page, the supply voltage and load of the contact, and whether you need auto or manual reset, because the KP 1 is built in several reset and connection versions that carry different code numbers. Seven Star LLC is an independent supplier in Muscat; send us this code number together with the refrigerant and the required setting and we will check availability.
Commissioning the KP 1 on a refrigeration system
Connect the switch to a point on the suction line where it sees true suction pressure, and avoid positions directly after valves or restrictions where pressure can fluctuate. Run the connecting line so that it cannot vibrate against the pipework or frame, and secure it with suitable clips. Tighten the 1/4 in flare connection carefully and leak-test it with the method used for the rest of the system.
Before starting the compressor, set the cut-in and differential from the system design values and confirm them with a calibrated gauge rather than relying only on the scale. During the first run, slowly reduce suction pressure, for example by closing the liquid line valve under supervision, and note the pressure at which the contact opens and the pressure at which it closes again. Adjust the spindles if the measured values differ from the target, and use the manual trip lever to confirm that the control circuit reacts as intended.
Wiring checks
Wire the SPDT contact according to the control circuit diagram, using the rubber cable gland with a cable inside its stated diameter range so that the IP44 enclosure is maintained. Check that the switched load stays within the contact ratings on this page and route larger motors through a contactor.
Plant room conditions in Oman and the GCC
Condensing units and cold rooms in Oman and the GCC often run in very hot plant rooms or on exposed rooftops. Keep the switch out of direct sun and away from hot discharge lines, and check that the ambient at the mounting point stays within the temperature range listed in the specification table. Dust and sand can enter through a poorly sealed cable entry or a cover left loose after adjustment, so refit the cover correctly after every setting change. In humid coastal sites, mount the switch so that condensate from cold pipework cannot drip onto it.
Periodic maintenance
During scheduled service visits, compare the actual cut-out and cut-in pressures with the commissioning record, inspect the flare joint for oil traces that indicate a leak, and check that the cable gland and cover are still sealed. If the compressor starts cycling frequently on low pressure, look first at the refrigerant charge, evaporator airflow and filter drier before changing the switch setting.
Documents and quotation
The attached file is the Danfoss KP pressure switch data sheet (AI552626450143), which covers the full KP 1 to KP 47 range, wiring, dimensions and ordering tables. For other pressure switches and thermostats see our pressure instrumentation category. Request a quotation with the code 060-110166 and quantity.
Datasheets & Documents
- Datasheet Danfoss KP pressure switch data sheet AI552626450143 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
It is a Danfoss KP 1 pressure switch: low-pressure control, regulating range -0.2 to 7.5 bar, differential 0.7 to 4.0 bar, SPDT contact, automatic reset, 1/4 in male flare connection, IP44.
Yes. This code has automatic reset, so the contact returns to its normal position when the pressure has risen by the set differential. Manual-reset KP 1 versions have different code numbers.
Danfoss lists a maximum working pressure of 17 bar and a maximum test pressure of 20 bar for this code. The switch is not meant for the liquid line.
The SPDT contact can switch a single-phase AC motor of up to about 2 kW directly. Larger or DC loads should be switched through a contactor in the control circuit.
The Danfoss KP pressure switch data sheet AI552626450143, unaltered. Confirm refrigerant, setting and connection with us before ordering.