Brand: ABB
ABB ACS480-04-09A5-4 General Purpose Drive 4 kW 9.4 A
Description
A 4 kW ACS480-04 for 400 V machines
Machine builders and panel shops who need 4 kW on a 400 V supply will meet the ACS480-04-09A5-4 in the ACS480 hardware manual. The drive provides 9.4 A nominal output on frame R1, with a built-in brake chopper, EMC category C2 filter and Safe Torque Off in the basic unit. The 4 kW rating is the largest R1 size and a frequent choice for small machines.
The standard unit includes a front option slot and a side option slot, a standard ACS-AP-S assistant control panel, an RIIO-01 module with digital, analog and relay I/O plus EIA-485 and an embedded Modbus RTU fieldbus. Neighbouring ratings are listed in AC drives, and ABB’s wall-mounted general purpose drive is described on the ABB ACS580 drive page.
Technical specifications
| Parameter | Specification |
|---|---|
| Type designation | ACS480-04-09A5-4 |
| Series / construction | ACS480 / 04 = module, IP20 (UL open type) |
| Supply voltage | 3-phase, 380 to 480 V (code 4) |
| Frame size | R1 |
| Nominal use | 4 kW, 9.4 A |
| Light-duty use | 4 kW, 8.9 A |
| Heavy-duty use | 3 kW, 7.2 A |
| Maximum current | 13 A |
| Input current (no choke / with choke) | 12.9 A / 9.4 A |
| gG fuse (IEC) | 16 A, OFAF000H16 |
| gR fuse (IEC) | 40 A, 170M2696 |
| Miniature circuit breaker | S 203P-B 16 |
| Typical power loss / air flow / noise | 140 W / 57 m3/h / 63 dB(A) |
| Derating factor at 8 / 12 kHz | 0.65 / 0.48 |
| Dimensions IP20 (H x W x D) | 223 x 73 x 208 mm |
| Weight IP20 | 1.7 kg |
Choosing between nominal, light and heavy duty
Match 8.9 A (light duty, 4 kW) or 7.2 A (heavy duty, 3 kW) to the motor. The nominal figure is 9.4 A for 4 kW and the peak is 13 A. Mains current: 12.9 A without a choke, 9.4 A with one.
Protection data from the manual: gG fuses of 16 A (OFAF000H16) with a minimum short-circuit current of 128 A, or gR fuses of 40 A (170M2696). A miniature circuit breaker alternative is S 203P-B 16. The drive dissipates about 140 W and needs 57 m3/h of cooling air at 63 dB(A).
Hot or high-altitude sites need derating: 0.65 at 8 kHz, 0.48 at 12 kHz, 1% per degree from +50 to +60 degrees C and 1% per 100 m above 1000 m. At the default 4 kHz no switching derating is required.
Physical data: frame R1, 73 x 223 x 208 mm, 1.7 kg, free space 75 mm above and below. UL Type 1 kit adds hood and connection box (293 mm, 2.1 kg). Cable guidance: 100 m maximum for operation, and for EMC 30 m for category C3 and 10 m for C2 with the internal filter, or 40 m for C1, C2 and C3 with the optional external filter.
How the code is built
The designation splits into series ACS480, construction 04 (module), rating 09A5 and voltage code 4. The plain code gives the standard unit; plus codes ABB lists include L515 for the BIO-01 I/O module, L534 for BAPO-01 external 24 V DC, J429 for the ACS-AP-W Bluetooth panel and J425 for the ACS-AP-I panel.
The technical data chapter also lists induction, permanent magnet and SynRM motor control, a short-circuit proof motor output, natural convection on R0 and a cooling fan on R1 to R4 and a choice of an IEC type or a UL (NEC) type for North America.
Documents and quotation
Seven Star LLC can quote the ACS480-04-09A5-4 from Muscat. Attach the motor nameplate and the supply voltage to your RFQ. The linked ABB hardware manual (3AXD50000047392, revision F) supplies the ratings, fuses, losses, derating and dimensions shown.
Please confirm the ordering code, panel and fieldbus options, and the site derating before you order.
Datasheets & Documents
- acs480hw Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
Related products
Frequently Asked Questions
ABB lists 9.4 A nominal for 4 kW, 8.9 A light duty for 4 kW and 7.2 A heavy duty for 3 kW, with a maximum current of 13 A.
The manual lists 16 A gG fuses of type OFAF000H16, 40 A gR fuses of type 170M2696, or the circuit breaker S 203P-B 16.
Frame R1 measures 223 mm high, 73 mm wide and 208 mm deep in IP20 and weighs 1.7 kg; with the UL Type 1 kit it weighs 2.1 kg.
Yes. ABB gives a derating factor of 0.65 at 8 kHz and 0.48 at 12 kHz; no derating is needed at 4 kHz.
The standard unit has the ACS-AP-S assistant panel, the RIIO-01 I/O and EIA-485 module, an EMC category C2 filter, Safe Torque Off and a brake chopper in IP20 module form.

Reviews