Brand:

Trafag EXNT 8292 Ex Pressure Transmitter

Description

Thin-film Ex ia pressure transmitter with hydrogen-compatible option

The Trafag EXNT 8292 is an intrinsically safe pressure transmitter based on Trafag thin-film-on-steel sensor technology. Trafag describes it as offering long-term stability and accurate pressure measurement over a wide temperature range, and certifies it to ATEX, IECEx and UKEX for gas Zones 0, 1 and 2, dust Zones 20, 21 and 22 and mining.

It gives a 4 to 20 mA output on a 10 to 30 VDC supply. A hydrogen-compatible sensor version is available, and the EC79/2009 type approval from the German KBA is listed for hydrogen applications on selected connections.

Technical specifications of the EXNT 8292

Parameter Specification
Manufacturer Trafag AG, Switzerland
Product code 8292
Measuring principle Thin-film-on-steel
Measuring range From 0 … 0.4 bar; ranges in bar and psi per datasheet table
Output signal 4 … 20 mA, 24 (10 … 30) VDC
Type of protection II 1G Ex ia IIC T4/T6 Ga; I M1 Ex ia I Ma; II 1/2G Ex ia IIC T4/T6 Ga/Gb
Approvals ATEX, IECEx, UKEX, DNV, KRS, RMRS, PESO; EC79/2009 on request
Accuracy at 25 °C 0.3 % FS or 0.5 % FS typical, by sensor code
Media / ambient temperature Maximum -40 to +120 °C, depending on electrical connection
Protection Minimum IP65; IP67 with cable or connection code 02
Vibration / shock 10 g (50 to 2000 Hz) / 50 g, 3 ms
Internal inductance / capacitance Li below 10 µH; Ci 23 nF or less
Wetted sensor 1.4542 (AISI 630); hydrogen-compatible steel option
Pressure connection 1.4542 up to 16 bar; 1.4404 above 16 bar
Housing 1.4301 (AISI 304)
Seals FKM or EPDM
Mounting torque 25 Nm; 30 Nm for connection code 29

The accuracy table in the datasheet gives a total error band over minus 25 to plus 85 degrees C of 2.0 percent FS for the 0.5 percent sensors and 0.5 percent FS for the 0.3 percent sensors, with a one-year long-term stability of 0.2 percent FS. These figures help when comparing the transmitter against a loop accuracy budget rather than only the headline accuracy at 25 degrees C.

Standard types and ordering

Trafag lists standard products with short lead times, with type codes such as EXNT0.4A, EXNT1.0A, EXNT10.0A, EXNT25.0A, EXNT100.0A and EXNT250.0A, each with a 0.5 percent accuracy, a G1/4 male connection and a DIN 43650-A plug. A 0 to 10 bar standard unit has an overpressure rating of 20 bar.

Other connections include G1/4 and G1/2 male and manometer threads, R1/4, 1/4 NPT and M18x1.5. Electrical options include DIN 43650-A, M12x1, MIL-C 26482 and Binder 723 plugs and shielded cable, with accessories for peak-damping elements, seals and a Zener barrier code ZEN28VDC rated 28 V and 93 mA.

Selecting and installing the transmitter

Check the electrical connection code before fixing the maximum media and ambient temperature, because Trafag ties the temperature limits to the connection type. For Zone 0 use, follow the marking for the metal connector versions and the guidance in the datasheet on plastic connectors, which are marked for Zone 1.

Pair the transmitter with a certified barrier or isolator, check the entity parameters against the Li and Ci values, and keep the 25 Nm mounting torque. For hydrogen service, ask for the hydrogen-compatible version and the matching connection code.

How the EXNT 8292 Ex pressure transmitter works

In thin-film-on-steel technology the strain gauges are deposited directly onto a stainless steel measuring element instead of being bonded or immersed in oil. Pressure deflects the element, and the resulting change of resistance in the bridge is converted by the electronics into a two-wire 4 to 20 mA signal. With no fill fluid and no internal elastomer seal at the sensor, the design is well suited to applications where long-term stability and robustness are important.

The hydrogen-compatible version uses a sensor steel chosen for hydrogen service. It is relevant for refuelling stations, electrolysers, fuel cell systems and hydrogen storage, where ordinary sensor materials can suffer from hydrogen permeation and drift over time.

For an Ex ia loop the transmitter must be connected through an approved associated apparatus, either a Zener barrier or a galvanically isolated barrier, located in the safe area or in a suitably protected enclosure. The entity parameters of the barrier, the cable capacitance and inductance and the internal values of the transmitter given in the datasheet must be compared so that the total stays inside the permitted limits. This calculation, together with the barrier certificate, forms part of the intrinsic safety descriptive system document for the loop.

Selection and installation tips

Choose the sensor accuracy code to match the loop budget, using the total error band rather than only the figure at 25 degrees C when the ambient temperature varies widely. Check that the electrical connection chosen supports the required media and ambient temperature, since the limit depends on it. Select FKM or EPDM seals according to the medium. Use an isolating valve and, where pulsation is present, a damping element. Tighten to the specified torque for the connection code and keep the cable entry sealed to maintain the ingress protection rating.

In every hazardous-area installation the instrument is only one part of the protection concept. The certificate conditions, the cable and gland selection, the earthing and the documentation all have to agree with the area classification. Keep a copy of the certificate and the datasheet with the loop or equipment file, and record the tag number, type code and serial number at installation so that later inspections can trace each device back to its approval.

Supply in Oman and the GCC

Seven Star LLC supplies Trafag EXNT 8292 instruments across Oman and the GCC for oil and gas, petrochemical, utilities and marine projects. Send the full type code or the details listed below and our team can help confirm the correct ordering code before you request a quote. Where a project has several measuring points, list them together so that ranges, connections and certification can be checked against one another in a single review rather than one tag at a time.

Documents and quotation

The Trafag datasheet for the EXNT 8292 (H72329ae, 07/2026) is available from the link below; the accessories datasheet is published separately by Trafag. Browse our Pressure Instrumentation category for related products.

To request a quote, send the type code or the pressure range, process connection, electrical plug, accuracy class and any hydrogen requirement.

Datasheets & Documents
  • PDF Datasheet Trafag EXNT 8292 Ex Pressure Transmitter datasheet (H72329ae) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Trafag is a Swiss manufacturer of pressure, temperature and gas density sensors and switches, founded in 1942 by Oscar Pfrunder and headquartered in Bubikon, near Zurich. It began as a transformer maker, which is where the name comes from, and from 1974 shifted its focus to measurement and control technology, introducing its first pressure transmitters in 1977. Trafag remains a family business.

Seven Star LLC is an independent supplier in Muscat. We list Trafag hazardous-area instruments for oil and gas, petrochemical and utility users in Oman and the GCC.

Trafag company profile

Founded 1942, Switzerland, by Oscar Pfrunder
Headquarters Bubikon, Switzerland
Ownership Family business
Original business Transformers; measurement and control focus from 1974
Markets Railways, hydraulics, shipbuilding, large engines, hazardous areas and power transmission
Product families NAT and EPI pressure transmitters, mechanical and electronic pressure switches, thermostats and temperature transmitters, SF6 gas density monitors and sensors, ATEX and IECEx explosion-proof sensors

Milestones

  • 1942: Oscar Pfrunder founds Trafag.
  • 1974: The company refocuses on measurement and control technology.
  • 1977: Trafag introduces its first pressure transmitters.

Trafag product series

Ex pressure transmitters include the EXNA 8852/8853 and EXNA 8854 transmitters and the EXNT 8292, and the EXNAL 8858 and 8859 are submersible pressure transmitters for level measurement.

Ex switches include the EXP 900/904/912 pressostat pressure switches, the EXPK 944/947/953 piston pressostats for high pressures, the EXS 404/414 Industat thermostats and the EXAS 409/419 Indu Ambistat room thermostats.

Trafag Ex transmitters use thin-film-on-steel or thick-film-on-ceramic sensor technology, chosen by range and medium, while the pressostats switch a microswitch directly from a diaphragm or piston with no supply voltage. The piston versions handle high pressures and pressure peaks, and the submersible EXNAL transmitters hang in tanks or wells to measure hydrostatic level.

Where Trafag instruments are used

Pressure and level measurement and switching in hazardous areas of wellsites, refineries, gas plants, tank farms and chemical plants, plus room temperature control in Ex-rated buildings and shelters.

Trafag products we list

Family Examples
Pressure Instrumentation EXNA 8852/8853 Ex Pressure Transmitter, EXNA 8854 Ex Pressure Transmitter, EXNT 8292 Ex Pressure Transmitter, EXP 900/904/912 Ex Pressostat Pressure S…, EXPK 944/947/953 Ex Piston Pressostat
Temperature Instrumentation EXAS 409/419 Ex Indu Ambistat Room Therm…, EXS 404/414 Ex Industat Thermostat
Level Instrumentation EXNAL 8858 Ex Submersible Pressure Trans…

Ordering Trafag instruments: what we need

Send the type and full order code, range, output or switch contact, process connection, electrical connection and the Ex certification needed (ATEX, IECEx or others).

Facts checked against Trafag's own company pages and image brochure (trafag.com), October 2026.

FAQ

Questions about the Trafag EXNT 8292 Ex Pressure Transmitter

Answers from our engineering team on installation, compatibility and integration.

01Which zones does the EXNT 8292 cover?
Gas Zones 0, 1 and 2, dust Zones 20, 21 and 22 and mining, under ATEX, IECEx and UKEX certification.
02Is a hydrogen version available?
Yes. Trafag offers a hydrogen-compatible sensor option and lists EC79/2009 certification by the German KBA.
03What is the output signal?
4 to 20 mA on a 10 to 30 VDC supply.
04What technology does the sensor use?
Trafag thin-film-on-steel sensor technology.
05What accuracy classes exist?
Typical accuracy at 25 degrees C is 0.3 or 0.5 percent FS, depending on the sensor code.